Study on the Agreement Values of Pulmonary Arterial Hypertension Measured by Cardiac Sonographers (심장초음파 검사자 간의 폐동맥고혈압 진단 측정값 일치도 분석 연구)

  • Seol Hwa KIM;Sundo JUNG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.4
    • /
    • pp.269-275
    • /
    • 2023
  • Echocardiography is a non-invasive method that is useful for diagnosing pulmonary arterial hypertension. It is known that echocardiography depends on the experience, education, and knowledge level of the cardiac sonographer. This study aimed to compare the agreement values between cardiac sonographer with different practical experiences in the diagnosis of pulmonary arterial hypertension using echocardiography. Three readers re-evaluated the echocardiography images of 148 patients who were diagnosed with pulmonary arterial hypertension at the S Medical Center from January 1, 2020, to December 31, 2020. The echocardiography values measured by each reader were compared and analyzed. The results of the analysis of discrete variables revealed that the agreement values of the cardiac sonographers showed excellent consistency for both reader 3 and the cardiologist group, indicating that more experience leads to better predictive accuracy for diagnosis of the condition. Furthermore, in terms of continuous variables, all the cardiac sonographer demonstrated good agreement in the measured values of the right atrium, which was easier to assess and clearer than the structurally complex measurements of the right ventricle. This study represents the first analysis in Korea of the agreement values measured by medical technologists who are cardiac sonographers.

A LOCALIZED GLOBAL DEFORMATION MODEL TO TRACK MYOCARDIAL MOTION USING ECHOCARDIOGRAPHY

  • Ahn, Chi Young
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.18 no.2
    • /
    • pp.181-192
    • /
    • 2014
  • In this paper, we propose a robust real-time myocardial border tracking algorithm for echocardiography. Commonly, after an initial contour of LV border is traced at one or two frame from the entire cardiac cycle, LV contour tracking is performed over the remaining frames. Among a variety of tracking techniques, optical flow method is the most widely used for motion estimation of moving objects. However, when echocardiography data is heavily corrupted in some local regions, the errors bring the tracking point out of the endocardial border, resulting in distorted LV contours. This shape distortion often occurs in practice since the data acquisition is affected by ultrasound artifacts, dropout or shadowing phenomena of cardiac walls. The proposed method deals with this shape distortion problem and reflects the motion realistic LV shape by applying global deformation modeled as affine transform partitively to the contour. We partition the tracking points on the contour into a few groups and determine each affine transform governing the motion of the partitioned contour points. To compute the coefficients of each affine transform, we use the least squares method with equality constraints that are given by the relationship between the coefficients and a few contour points showing good tracking results. Many real experiments show that the proposed method supports better performance than existing methods.

The Usefulness of Transesophageal Echocardiography During Heart Surgery (개심술을 시행하는 환자에서 경식도 심초음파의 이용)

  • 조규도;김치경
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1205-1213
    • /
    • 1997
  • This study reviewed useful aspects of the intraoperative transesophageal echocardiography among the patients in whom heart surgery were undertaken between January 1996 and July 1996 at St.Pauls hospital, Medical College of Catholic University, Seoul, Korea. During that period, 61 patients were operated on because of valvular heart disease(25 patients), coronary artery disease(22 patients), congenital heart disease(13 patients), and combined coronary artery disease and valvular heart disease(1 patient). Two patients(1 redo-VSD and 1 valvular heart diease) needed repeated aortic cross clamping and complementary procedures because of incomplete initial procedures. There was no incidence of air embolism. We could observe significant relationship of cardiac output monitoring methods either by thermodilution technique and transesophageal echocardiography by linear regression analysis(p<0.001). We tested myocardial response(percentage of systolic wall thickness, PSWT) with low dose dobutamine challenge to predict post-CABG myocardial perfusion. And the test showed statistically significant resp.onse(sensitivity 76%, specificity 94.7%, positive predictive value 95%, negative predictive value 75%). These results suggest that cardiac surgeon could draw more benefits by intraoperative transesophageal echocardiography.

  • PDF

Echocardiographic evaluation of heart failure in dogs with myxomatous mitral valve disease: a retrospective study

  • Han, Donghyun;Lee, Dong-Guk;Jung, Dong-In
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.79-85
    • /
    • 2018
  • Echocardiography is one of the most useful diagnostic techniques for differentiating heart disease as well as mitral valve lesion. Forty client-owned small breed dogs (weight, 2.3-13.2 kg) aged between 8-17 years with myxomatous mitral valve degeneration (MMVD) were included in the present study. The diagnosis of MMVD in dogs was made based on the clinical signs, chest radiography data, and echocardiographic findings. Echocardiographic examinations were conducted in accordance with recommended standards for dogs. M-mode, Doppler, and 2D echocardiography were performed in left and right lateral recumbency. 2D echocardiography was used to measure LA and Ao diameter from 2D short axis at the level of the aortic valve. In the comparison of conventional echocardiography indices in dogs with different stages of heart failure with MMVD, significant differences were observed in E/A ratio (p=0.005), EDV (p<0.001), EDVI (p<0.001), E-peak velocity (p= 0.001), ESV (p=0.028), ESVI (p=0.004), LA (p<0.001), LA/Ao Ratio (p<0.001), LVIDd (p<0.001), LVIDd/Ao Ratio (p<0.001), LVIDs (p=0.036), LVIDs/Ao Ratio (p=0.002), and MR Velocity (p=0.026). In addition, distinct correlations were found in EDV (r=0.712), LA/Ao ration (r=0.830), LVIDd (r=0.724), and LVIDd/Ao ratio (r=0.759). This study found that known conventional echocardiographic indices, including EDV, LA/Ao ratio, LVIDd dimension, and LVIDd/Ao ratio correlated with the severity of MMVD in point of significant differences and distinct correlations.

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF

Apical Hypertrophic Cardiomyopathy with Apical Aneurysm and Thrombus Diagnosed by Contrast Echocardiography (조영 심초음파를 통하여 진단된 심첨성 비후성 심근병증에 발생한 혈전을 동반한 심실류 1예)

  • Park, Kyu-Hwan;Hong, Geu-Ru;Nam, Jong-Ho;Kang, Min-Kyu;Kim, Su-Mi;Jung, Seong-Yoon;Na, Ji-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.27 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • Apical hypertrophic cardiomyopathy is rare disease and a variant of hypertrophic cardiomyopathy with prevalence of 1 in 500 in the general population. Apical hypertrophic cardiomyopathy with apical aneurysm and intramural thrombus is extremely rare. We report a case of apical hypertrophic cardiomyopathy progressing to left ventricular apical aneurysm with intramural thrombus diagnosed by contrast echocardiography.

  • PDF

Comprehensive understanding of atrial septal defects by imaging studies for successful transcatheter closure

  • Song, Jinyoung
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.7
    • /
    • pp.297-303
    • /
    • 2014
  • Transcatheter closure of atrial septal defects has become a popular procedure. The availability of a preprocedural imaging study is crucial for a safe and successful closure. Both the anatomy and morphology of the defect should be precisely evaluated before the procedure. Three-dimensional (3D) echocardiography and cardiac computed tomography are helpful for understanding the morphology of a defect, which is important because different defect morphologies could variously impact the results. During the procedure, real-time 3D echocardiography can be used to guide an accurate closure. The safety and efficiency of transcatheter closures of atrial septal defects could be improved through the use of detailed imaging studies.

Traumatic Aortic Rupture Using Transesophageal Echocardiography - A Case - (경식도 초음파로 진단된 외상성 대동맥 파열[1예 보고])

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.335-340
    • /
    • 1992
  • Truamatic aortic rupture is usually fatal if left untreated. Prompt diagnosis is the cornerstone of suscessful management. But the usual screening tests are non specific and the accuracy of computerized tomography is low, Aortography which is a time consuming procedure may result in false-positive interpretations and significant morbidity. Recently transesophageal echocardiography provides a rapid, effective and relatively safe means of evaluating the distal aortic arch and also affords the opportunity to evaluate the heart during the same study, which may be of benefit in cases of suspected cardiac injury. The experience with the traumatic aortic ruptured patient and a critical review of the literature suggests that transesophageal echocardiography is a useful technique for the diagnosis of ruptured aorta following blunt chest trauma.

  • PDF

Echocardiographic parameters and indices in 23 healthy Maltese dogs

  • Tsai, Chih-Hung;Huang, Chao-Chun;Ho, Chia-Chi;Claretti, Marta
    • Journal of Veterinary Science
    • /
    • v.22 no.5
    • /
    • pp.60.1-60.9
    • /
    • 2021
  • Background: Echocardiography is a primary tool used by veterinarians to evaluate heart diseases. In recent years, various studies have targeted standard echocardiographic values for different breeds. Reference data are currently lacking in Maltese dogs and it is important to fill this gap as this breed is predisposed to myxomatous mitral valve disease, which is a volume overload disease. Objectives: To establish the normal echocardiographic parameters for Maltese dogs. Methods: In total, 23 healthy Maltese dogs were involved in this study. Blood pressure measurements, thoracic radiography, and complete transthoracic echocardiography were performed. The effects of body weight, age and sex were evaluated, and the correlations between weight and linear and volumetric dimensions were calculated by regression analysis. Results: The mean vertebral heart size was 9.1 ± 0.4. Aside from the ejection fraction, fractional shortening, and the left atrial to aorta root ratio, all the other echocardiographic parameters were significantly correlated with weight. Conclusion: This study describes normal echocardiographic parameters that may be useful in the echocardiographic evaluation of Maltese dogs.

Delayed Diagnosis of Traumatic Rupture of Anterior Papillary Muscle of Tricuspid Valve; Importance of Trans-Esophageal Echocardiogram in the Evaluation of Major Blunt Chest Trauma

  • Bylsma, Ryan;Baldawi, Mustafa;Toporoff, Bruce;Shin, Matthew;Cochran-Yu, Meghan;Ramsingh, Davinder;Parwani, Purvi;Rabkin, David G.
    • Journal of Trauma and Injury
    • /
    • v.34 no.2
    • /
    • pp.136-140
    • /
    • 2021
  • We present a case of delayed diagnosis of traumatic tricuspid valve rupture in a patient who was emergently brought to the operating room for repair of lacerations to the heart and liver without intraoperative transesophageal echocardiography (TEE). Initial postoperative transthoracic echocardiography (TTE) did not show structural pathology. One week later, TTE with better image quality showed severe tricuspid regurgitation. Subsequently, TEE clearly demonstrated rupture of the anterior papillary muscle and flail anterior tricuspid leaflet. The case description is followed by a brief discussion of the utility of TEE in the setting of blunt thoracic trauma.