• Title/Summary/Keyword: egress

Search Result 208, Processing Time 0.028 seconds

Egress Safety of Nursing Hospital Considering Egress Guides and Smoke Exhaust System (피난유도자 수와 배연설비를 고려한 요양병원의 피난안전성 평가)

  • Choi, Seung-Ho;Darkhanbat, Khaliunaa;Heo, Inwook;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.64-71
    • /
    • 2022
  • In this study, fire and egress simulation was conducted for the egress safety evaluation of the nursing hospitals. A fire simulation was performed with or without the smoke exhaust system using the FDS, and the available safe egress time (ASET) of the nursing hospitals was calculated. In addition, an egress simulation considering the characteristics of occupants and egress delay time was performed using Pathfinder, and the required safe egress time (RSET) was calculated. By comparing the ASET and RSET, the egress safety of the nursing hospital with or without a smoke exhaust system was evaluated according to the number of egress guides and the egress delay time. The simulation results show that the number of casualties increased as the egress delay time increased, and the required safe egress time decreased as the number of egress guides increased. In addition, it was found that if a smoke exhaust system with the capacity specified in the KFPA is secured, the available safe egress time can be greatly increased and the number of casualties can be greatly reduced.

The Evaluation of the Egress Performance in the Buildings Installed with Luminous Egress Guide-lines (건축물내 자체발광식 피난유도선 설치에 따른 피난성능 평가)

  • Park, Yong-Hwan;Kim, Beom-Gyu;Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.120-126
    • /
    • 2011
  • Recently luminous egress guide-lines are introduced for the fire safety of residents in the multi-use buildings such as Gosiwon. Little literature, however, on the quantitative and qualitative estimation for the egress performance of the luminous egress guide-lines can be found. This study carried out experimental investigations to evaluate the egress performance of the existing egress guide-lights and new luminous egress guide-lines. The results showed that both luminous egress guide-lines and egress guide-light satisfied the basic performance of KFI requirements. Under the 7 % smoke transmittance, however, luminous egress guide-lines showed 3 times longer visibility and less evacuation time than egress guide-lights. The evacuation density and smoke transmittance have significant effect on the evacuation time increase without the luminous egress guide-lines, however little effect with the installation.

A Study on the Improvement of Means of Egress Based on NFPA 101 (NFPA 101 피난 안정성 평가에 기초한 피난 규정 개선 방향 연구)

  • Kyeung-Ho Kang;Suck-Hwan Joung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • The object of this study is to evaluate whether the means of egress of Jechon Sports Center and Miryang Sejong Hospital, where massive fire human casualties occurred in 2017 and 2018 respectively, comply with NFPA 101(Life Safety Code), and to suggest the need for supplementation of domestic means of egress regulations. The study evaluated the number and arrangement of the means of egress, travel distance, common path of travel, dead end and discharge from exit for each building by applying the means of egress regulations of NFPA 101. As a result of the evaluation through NFPA 101, the travel distance was appropriate, but some of the other items except for the travel distance did not meet NFPA 101. The regulations that need to be supplemented are 1)occupant load calculation 2)egress capacity calculation 3)continuous concept of means of egress 4)concept of common path of travel. It is especially necessary to revise the requirement for fire door of the evacuation floor(normal 1st floor) of the stairwell in case of below the five story building.

Ingress/ Egress of Older Drivers Part 1: Analysis of Motion Characteristics (고령운전자의 승/하강 거동 Part 1: 특성 분석)

  • Choi, W.J.;Sha, S.J.;Choi, H.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.5
    • /
    • pp.381-392
    • /
    • 2009
  • Due to the aging effect, older people have relatively weaker muscular performance, less range of motion in the joint articulation, and the lower sense of equilibrium than younger people. These factors attribute to their slow and clumsy ingress/egress motion. In order to analyze ingress/egress motion strategy of the elderly, healthy thirty 65 or more years old volunteers were recruited. The health condition of the each volunteer was verified by the medical checkup and also their physical capabilities were quantified by six fitness tests. Through the video analysis, older driver's ingress/egress motion strategies were classified and statistically investigated. For a comparison purpose, another thirty young volunteers also participated in the same test protocol and their ingress/egress motion strategies were also included in the statistical analysis.

Ergonomic Evaluation of Convenient Appliances for Elderly Driver's Ingress/Egress (고령자 승/하강 편의장치에 대한 효과 검증 및 개선방향 연구)

  • Park, Woo-Chul;Yang, Young-Seon;Jang, Chee-Hwan;An, Dae-Jin;Lim, Sung-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • The objective of this paper is to study the usability of the ingress/egress of elderly people, and analyze the physiological workload electromyography (EMG). We investigated the factors of discomfort while the elderly people are using the ingress/egress. Experiments were performed using a seating buck with 22 elderly participants (over 65 years old). The results showed that different muscles are activated during ingress and egress. A system called "easy access" was found which helps to access easily when a driver gets into a car. The current easy access was compared a newly proposed one. It was found that elderly people use less muscle during in/egress in the new easy access system.

A Study on Evacuation of Patients in Hospitals : Part II (병원 피난에 관한 연구 : Part II)

  • Kim Eung-Sik;Lee Jeong-Su;Park Seong-Min;You Hee-Kwon
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.28-36
    • /
    • 2005
  • The goal of this study is establishment of egress parameters and algorithm for estimation of total egress time in hospitals. Therefore, egress parameters should be measured and analyzed via the experiment at many hospitals. In this study, 4 general hospitals were experimented and egress parameters were measured, the comparison between experimental results and estimated total egress time were carried out. The algorithm for estimation of total egress time can be applied to other hospitals.

Analysis of Tendency and the Method Improving Ingress and Egress for Wheelchair Users (휠체어 사용자의 자동차 승하강성 문제점 분석 및 개선 방안)

  • Cho, Sung-Il;Park, Sung-Joon;Hong, Seung-Woo;Choe, Jae-Ho;Jung, Eui-Seung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.23-32
    • /
    • 2008
  • This study attempts to develop improved ingress and egress in vehicle for disabled wheelchair people who driving is available, after investigating the ingress and egress relation demand and the inconvenient factor in the vehicle. An experiment was performed for that disabled wheelchair people to analyze the characteristics of ingress and egress relation operation through the questionnaire survey and the camera photographing. The results suggest various improvements possibilities in inside handlebar as a main factor. Through analysis of disabled wheelchair person's ingress and egress tendency, the alternative shape and position of inside handlebar are suggested. Also, this paper aimed to draw ingress and egress improvement proposal by executing a verification experiment and collecting the preferences from disabled people.

A Study on Egress Algorithm for High-rise Buildings Using Egress Simulation (피난시뮬레이션을 이용한 초고층건물의 피난 알고리즘 연구)

  • Kim, Won Kook;Seo, Dong Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • When the fire in the high-rise building was not extinguished in its early stage and propagated over its origin, safe egress becomes one of the most important factor to minimize the casualties. Recently fire protection for high-rise building has been reinforced after experiencing the series of disastrous fires. But, we still find many high-rise buildings do not comply with those reinforcement. And also there is a possibility of failure of reinforced fire protection system. Under these situation safe egress guide would be the final layer of protection. In this study existing egress methods were identified and evaluated. According the result of study, priority in egress should be given to the tenants on the floor of fire origin and floors exposed to the risk of fire. Then, the rest of the tenants can be evacuated simultaneously. Floors exposed in fire risk shall be determined by fire tests and/or fire simulations. But, the result of fire monitoring shall override preliminary estimations. Egress time for each algorithm was estimated by egress simulation and the result was compared. There was a little difference in egress time between total egress and phased egress, and a big difference between using stairs only and using elevators and stairs together. to a constant thickness between layers constituting a firefighter's protective clothing should be considered in the future.

A Study on the Egress distance of Semiconductor factory (반도체공장의 피난거리 연구)

  • Lee, Yong-Jae;Lee, Kung-Koo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.189-194
    • /
    • 2008
  • Augmentation of the high-technology industry semiconductor factories, to acquire productivity and competitive power, is an international tendency. This situation is demanding for the functional counteractions. This study is regarding egress distance pertaining to installation of direct stairs. First, analyze situations and danger characteristics of LCD Factories. Second, through investigations and analysis of both domestic and foreign Egress Distance Code, propose rational Egress Distance Code pertaining to installation of direct stairs.

  • PDF

Access and Egress Patterns of Travel to a Regional Railway Station Based on Transit Smart Card Data (Case study: Seoul Station during Chuseok Holiday) (명절기간 중 서울역 철도 이용객의 접근통행 특성 연구)

  • Eom, Jin Ki;Lee, Jun;Lee, Kwang-Seop
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.1
    • /
    • pp.59-64
    • /
    • 2013
  • This study analyzed passenger access and egress travel patterns related to a Korean regional railway station (Seoul station), then developed a binomial logit model. This model referred to bus and metro mode of access and egress during a national holiday (Chuseok 2009); obtained from transit smart card data. The results showed that 99% of passengers getting access to, or egress from, the regional railway station did so using less than two transfers, and that most passengers were more likely to choose a metro. However, the passengers that made access or egress trips near Seoul Station were more likely to take a bus. From the results of the mode choice model, it was found that the impact of travel time was greater than that of travel cost, in the choices made for both access and egress. Interestingly, the impact of travel time is much greater in choosing the mode of egress.