• Title/Summary/Keyword: electric charge

Search Result 1,126, Processing Time 0.028 seconds

Design and Implementation of Distributed Charge Signal Processing Software for Smart Slow and Quick Electric Vehicle Charge

  • Chang, Tae Uk;Ryu, Young Su;Song, Seul Ki;Kwon, Ki Won;Paik, Jong Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.3
    • /
    • pp.1674-1688
    • /
    • 2019
  • As environmental pollution and fossil fuel energy problems from fuel vehicle have occurred, the interest of electric vehicle(EV) has increased. EV industry and energy industry have grown dynamically in these days. It is expected that the next generation of primary transportation will be EV, and it is necessary to prepare EV infra and efficient energy management such as EV communication protocol, EV charge station, and smart grid. Those EV and energy industry fields are now on growth. Also, the study and development of them are now in progress. In this paper, distributed charge signal processing software for smart slow and quick EV charge is proposed and designed for dealing with EV charge demand. The software consists of smart slow and quick EV charge schedule engine and EV charge power distribution core. The software is designed to support two charge station types. One is normal EV charge station and the other is bus garage EV charge station. Both two types collect the data from EV charge stations, and then analyze the collected data. The software suggests optimized EV charge schedule and deliveries EV charge power distribution information to power switchboard system, and the designed software is implemented on embedded system. It is expected that the software provides efficient EV charge schedule.

Electric Charge and Magnetic Flux on Astrophysical Black Hole

  • LEE HYUN KYU
    • Journal of The Korean Astronomical Society
    • /
    • v.34 no.4
    • /
    • pp.301-303
    • /
    • 2001
  • We suggest a possible scenario of an astrophysical black hole with non-vanishing electric charge and magnetic flux. The equilibrium charge on a rotating black hole in a force-free magnetosphere is calculated to be Q $\~$ BJ with a horizon flux of ${\~}BM^2$, which is not large enough to disturb the background Kerr geometry. Being similar to the electric charge of a magnetar, in sign and order of magnitude, both electric charge and magnetic flux are supposed to be continuous onto a black hole.

  • PDF

The Effect of Fixed Oxide Charge on Breakdown Voltage of p+/n Junction in the Power Semiconductor Devices (전력용 반도체 소자의 설계 제작에 있어서 Fixed oxide charge가 p+/n 접합의 항복전압에 미치는 영향)

  • Yi, C.W.;Sung, M.Y.;Choi, Y.I.;Kim, C.K.;Suh, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.155-158
    • /
    • 1988
  • The fabrication of devices using plans technology could lend to n serious degradation in the breakdown voltage as a result of high electric field at the edges. An elegant approach to reducing the electric field at the edge is by using field limiting ring. The presence of surface charge has n strong influrence on the depletion layer spreading at the surface region because this charge complements the charge due to the ionized acceptors inside the depletion layer. Surface charge of either polarity can lower the breakdown voltage because it affects the distribution of electric field st the edges. In this paper we discuss the influrences of fixed oxide charge on the breakdown voltage of the p+/n junction with field limiting ring(or without field limiting ring).

  • PDF

Effect of Electric Charge on the Operating Behavior of Air-conditioner and Thermal Comfort in Summer Season (여름철 전기요금이 거주자의 냉방기 조작과 온열감에 미치는 효과)

  • Kwon, Suh-Hyun;Bae, Nu-Ri;Chun, Chung-Yoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.703-709
    • /
    • 2007
  • Much energy is used in occupying stage of the Building Life Cycle. Electric charge is one of the various factors that influence on energy use of residents. This study focused on electric charge and searched that whether electric charge affects residents' behavior of operating air conditioner and their controlled indoor climate. We surveyed three groups for field study ; A group is residents who live in a studio apartment, B group is residents who live in a university dormitory and C group is residents who live in a apartment with their family. The A and C groups are charged for electric as energy consumption they used. And the B group is students who live in a university dormitory and they are not charged for their energy consumption. We measured the time to use the air conditioner for cooling, on/off temperature of air conditioner, and room air temperature for these three groups. The result shows that consideration for electric charge affects to the residents' behavior of operating air conditioner and their acceptable thermal range.

Evaluation of the Effective Charge Density on Low Pressure Nanofiltration with the Separation Characteristics of Monovalent and Divalent Solutes in the Production of Drinking Water

  • Oh, Jeong-Ik;Taro, Urase
    • Environmental Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • The electric charge on a membrane was investigated by analyzing the experimental rejection of various monovalent and divalent ionic solutes. The characteristics of the separation of ionic solutes using various nanofiltration membranes were obtained from an experimental nanofiltration set-up, with a surface area of $40cm^2$ under the operational pressures between 0.25-0.3 MPa. The state of the membrane electric charge was observed using separation coefficients, i.e., the permeation ratio of monovalent to divalent ions. To confirm the state of the membrane charge observed via the separation coefficient, a calculation using the extended Nernst-Planck equation, coupled with the Donnan equilibrium, assuming different electric charge states of the membrane, was compared with the experimental rejection of ionic solutes. The examination of the characteristics of separation using three types of nanofiltration membranes showed that one of the membranes carried a negative/positive double charge density inside, while other two membranes carried either a positive or negative charge density.

Three Dimensional Electric Field Analysis Of Substation Using Nonuniform Optimal Charge Simulation (비균등 최적 전하배치를 이용한 전력소 3차원 전계해석)

  • Myung, Sung-Ho;Lee, Byeong-Yoon;Min, Suk-Won;Kim, Eung-Sik;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.290-292
    • /
    • 1994
  • This paper presents a methodology for the electric field analysis of substation. For the electric field analysis of substation, the electrodes(substation busbars) must be represented by finite line with nonlinear charge density. In the case of dividing finite line into uniform segments, a large number of variables have to be used to obtain the accuracy within a desired tolerance. To deal with the problem, nonuniform charge arrangement modeling method is suggested. To reduce potential calculation errors, the linear charge density function is considered particularly for the segment charge model ling. If the charge arrangement is improper, the accuracy not improved regardless of increment in the number of segments. This paper proposes an optimal charge arrangement method through potential error analysis. And, the optimal charge arrangement function is formulated by a lot of simulation results.

  • PDF

Interfacial charge Behaviors in XLPE/SXLPE Laminates (XLPE/SXLPE laminate의 계면전하 거동)

  • 고정우;남진호;서광석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.897-900
    • /
    • 2001
  • Space charge distributions in silane crosslinked polyethylene (SXLPE)/ crosslinked polyethylene (XLPE) laminates was investigated using a pulsed electroacoustic (PEA) method. XLPE shows heterocharge while SXLPE shows homocharge. Positive charge is accumulated at the interface of SXLPE/XLPE laminate when applied electric field is more than 20 kV/mm. The charge profile at various temperatures was also acquired using temperature-controllable PEA system. Although applied electric field is only 8.6 kV/mm, positive interfacial charge starts to appear near 50$^{\circ}C$.

  • PDF

A Study on the changes of electric charge induced by Apchim (押鍼) manipulation during acupuncture therapy (자침시(刺鍼時) 압침(押鍼)의 수기자극(手技刺戟)이 전위변화(電位變化)에 미치는 영향(影響))

  • Song, Moon-Young;Shim, Won-Bo;Kim, Young-Tae;Baek, Dae-Bong;Ahn, Sung-Hun;Kim, Kyoung-Sik;Sohn, In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.22 no.4
    • /
    • pp.9-27
    • /
    • 2005
  • Objective : hypothesis. First of all, there exists electric property in meridian and meridian point. Second of all, energy flowing in meridian is related with electric property. Third of all, there is electronic interaction between the operator who performs acupuncture therapy and the receiver who is given acupuncture therapy. Forth of all, acupuncture effects may depend on the electric capacity which is transferred between the operator and the receiver via acupuncture needle. Methods : Under the hypothesis, I studied the effects of electric charge in ST37(+) and ST39(-) generated by Apchim (押鍼) manipulation which was stimulated at ST36 point. And compared with data on the changes of electric charge from the hand of the operator during acupuncture stimulation. Electric charge induced via acupuncture needle from the operator may be important factor that causes the changes of electric charge in meridian and acupoint in the receiver. Therefore we investigated the changes of electric charge induced by the operator using Maclab 400 by the following methods. The one was in stable electric circle condition and the other was in unstable electric circle condition. In this experiments, the changes of electric charge from the stimulation type of Apchim manipulation performed in our lab condition in acupuncture therapy was induced at least three factor, one was the difference of bio-potentials between the operator and the receiver of acupuncture therapy, another was the depth of acupuncture insertion from the skin of the receiver the other was an electromyogram of the receiver. Results :The data imply that the first factor should make a capacitance current when the operator touched the acupuncture needle which was inserted in the receiver. Therefore, the results suggest that capacitance currents stimulus in electronic view may be important factor in acupuncture therapy between the operator and the receiver of acupuncture therapy.

  • PDF

Analysis of Vanadium Ions and SOC in the Electrolytes of VRFB-ESS (VRFB-ESS용 전해질의 이온가수 분석방법 및 SOC 분석)

  • Seo, Hai-Kyung;Park, Wonshik;Kim, Kangsan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.309-316
    • /
    • 2021
  • For the detection of the state of charge in VRFB-ESS, the analyses of UV-Visible spectrometry and the measurements of potential between the anolyte and catholyte were used in parallel. This paper includes the production of 4-valant ion from VOSO4 powder, 3- and 5-valant ions from electrochemical charge of 4-valant ion and 2-valant ion from 3-valant ion. It also includes the analyses of these valance ions and unknown electrolyte at any time using UV-Visible spectrometry. Through the analyses of the valance ions in samples, the SOCs of the samples at any charge-discharge times were verified.

A study of the hazard of fire and explosion due to electric charge by Gas-Solids flow in pipeline

  • Chung Jae Hee;Seo Dae Won;Koo Ja Hyeuk;Kim Sung Jun;An Heau Seak;Kim Joon Ho;Hong Sung Kyung;YAMAGUMA Mizuki;KODAMA Tsutomu
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.33-38
    • /
    • 2000
  • When fire and explosion accidents have occurred due to a leak of the flammable gas involving the LNG & LPG in an industrialized society, it is a very important problem. Accordingly, in this paper, we have compared and analyzed the occurrence transition and the electrostatic energy according to dust supplies and pressure variations for the electric charge due to the gas-solids of pipe flow. As the experimental results, if dust amounts and the initial pressure increased, electric charge in the pipe and the exit increased. The Specific charge of $Fe_2O_3$ increased proportionally if the initial pressure increased but if the quantity of dust increased, the specific charge decreased. Energy increased significantly as the dust amounts and the initial pressure increased. The possibility of fire and explosion exist in the measuring point(M 1) and the Faraday cage if natural gas and LPG were used.

  • PDF