Search Result 694, Processing Time 0.02 seconds

On-Line Monitoring of Power Apparatus with Infrared Thermography (적외선 열화상을 이용한 수전설비 온라인 감시)

  • Lim, Young-Bae;Jeong, Seung-Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.441-444
    • /
    • 2004
  • Each electrical apparatus radiates various infrared as the condition of surface and load current. Because heat distribution of the apparatus changes as the condition, it is able to analyze the condition of the apparatus by using the distribution. However, methods having been used to measure the heat distribution cannot compare normal condition with abnormal, and the apparatus has diagnosed by intuition. This paper deal with a program that is able to analyze changed temperature distribution. The program is to analyze temperatures on pixels in selected region of interest or position and is able momently and logically to analyze condition of the apparatus. The results are able to apply to a on-line monitoring system.

  • PDF

Optimization Design for Dynamic Characters of Electromagnetic Apparatus Based on Niche Sorting Multi-objective Particle Swarm Algorithm

  • Xu, Le;You, Jiaxin;Yu, Haidan;Liang, Huimin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.660-665
    • /
    • 2016
  • The electromagnetic apparatus plays an important role in high power electrical systems. It is of great importance to provide an effective approach for the optimization of the high power electromagnetic apparatus. However, premature convergence and few Pareto solution set of the optimization for electromagnetic apparatus always happen. This paper proposed a modified multi-objective particle swarm optimization algorithm based on the niche sorting strategy. Applying to the modified algorithm, this paper guarantee the better Pareto optimal front with an enhanced distribution. Aiming at shortcomings in the closing bounce and slow breaking velocity of electromagnetic apparatus, the multi-objective optimization model was established on the basis of the traditional optimization. Besides, by means of the improved multi-objective particle swarm optimization algorithm, this paper processed the model and obtained a series of optimized parameters (decision variables). Compared with other different classical algorithms, the modified algorithm has a satisfactory performance in the multi-objective optimization problems in the electromagnetic apparatus.

A Study on the Motor Overload Interrupt system (전동기 과부하 차단 시스템에 대한 연구)

  • Choi Jang Gyun;Yoon Suk Am;Gang Byeong Bog;Lee Jeong Il;Cho Kyeng Jai;Cha In Su
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.73-76
    • /
    • 2002
  • In electrical machinery and apparatus, the most important problem is protect of machinery and apparatus in due to transient phenomena and overload on operation. Particularly by advanced technology of late, there Is demand for low cost of equipments and high percentage of use of equipments. Therefore, protection of machinery and apparatus In condition of overload is more valued considering that all efficiency increase is passed by operating all machinery and apparatus in condition of heavyload. In this paper, the suggested system is added overload interrupt system using CT in condition of overload.

  • PDF

A Study on the motor's overload protect system applying PIC (PIC를 적용한 Motor 과부하 방지 시스템에 대한 연구)

  • Kang, Byung-Bog;Yoon, Su-Am;Lim, Jung-Yeol;Yoon, Jung-Phil;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.28-30
    • /
    • 2002
  • In electrical machinery and apparatus, the most important problem is protect of machinery and apparatus in duo to transient phenomena and overload on operation. Particularly by advanced technology of late, there is demand for low cost of equipments and high percentage of use of equipments. Therefore, protection of machinery and apparatus in condition of overload is more valued considering that all efficiency increase is passed by operating all machinery and apparatus in condition of heavyload. In this paper, the suggested system is add overload protect system using CT in condition of overload.

  • PDF

Constructional Properties and Evaluation Methods of the Non-Incendive Type of Explosion-Proof Electrical Apparatus (비점화(非點火)(Non-Incendive)형(型) 방폭(防爆) 전기기기(電氣機器)의 구조특성(構造特性) 및 평가방법(評價方法))

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.110-113
    • /
    • 1994
  • In the hazardous areas where explosive substances in the form of gases, vapor or mists exist, electrical apparatus and installations must be of explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, six types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, and special types. If electrical apparatus are made of explosion-proof construction in a way other than five above-mentioned types, and their performance is tested and approved by the reponsible authorities, they may be categorized as special type apparatus. In this paper, we introduced a special type of explosion-proof electrical apparatus, called non-incendive type, and presented its constructional requirements. We also investigated evaluation methods of non-incendive type apparatus to assure the explosion-proof performance, and proposed a new classification method of hazardous areas using probabilistic concept.

  • PDF

Investigation of the Supercritical Fluids as an Insulating Medium for High Speed Switching

  • Shon, Chae-Hwa;Song, Ki-Dong;Oh, Yeon-Ho;Oh, Ho-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1783-1786
    • /
    • 2016
  • The paper investigates the insulation properties of the supercritical $CO_2$ ($SCCO_2$) fluid as an insulating medium for electrical apparatuses. The insulating material is crucial for electrical apparatuses and $SF_6$ gas has been widely used for high power electrical apparatuses. There have been many research efforts to develop substituents for $SF_6$ gas because of high global warming potential. We obtained above 350 kV/mm insulation strength with 12.0 MPa $SCCO_2$. The positive and negative IEC standard pulses are applied between two 10 mm diameter spherical electrodes. The insulation strength of $SCCO_2$ is at least 2.5 times higher than that of $CO_2$ gas at 6.0MPa. The insulation strength of $SCCO_2$ fluid is about 10 times higher than that of $SF_6$ at 0.5MPa which is the ordinary operating pressure of electrical switchgears. Using the result, we expect that the time for switching and dielectric recovery could be reduced using $SCCO_2$ fluid as an insulating medium.

The Study on the Characteristics of Leakage Circuit Breakers in Protection of the Low Voltage Electrical Apparatus (저압전기기기의 보호를 위한 전류동작형 누전차단기의 특성에 관한 연구)

  • 김은배;오철수
    • 전기의세계
    • /
    • v.25 no.4
    • /
    • pp.59-62
    • /
    • 1976
  • This study on the characteristics of the leakage circuit breakers handles the rolls of each itemized parts of the mentioned apparatus and their influence in determining of the characteristic curve of leakage circuit breaker. Furthermore the differential current transforms in the mentioned apparatus for detecting the fault is handled as a heavy point.

  • PDF

A Study on the Lightning Impulse Dielectric Characteristics of Air for the Development of Air-Insulated High Voltage Apparatuses (고전압 전력기기 개발을 위한 기중 절연파괴특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1005-1010
    • /
    • 2011
  • The accidents caused by dielectric instability have been increasing in power grid. It is important to enhance the dielectric reliability of a high voltage apparatus to reduce the damage from electrical hazards. To develop an electrically reliable high voltage apparatus, the experimental study on the electrical breakdown field strength is indispensable, as well as theoretical approach. In this paper, the lightning impulse breakdown characteristics considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only maximum electric field intensity but also utilization factors of electrode systems. The results are expected to be applicable to designing the air-insulated high voltage apparatuses.

a Survey on the Actual Condition of Lighting Apparatus (일반용 및 산업용 조명기구 보급실태조사)

  • 곽희로;이진우;김문덕;강원구
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.3
    • /
    • pp.67-72
    • /
    • 1995
  • In this paper, we investigate the numbers and electrical capacities of general and industrial Korean lighting apparatus. The results show that the number of lighting apparatus are 68,211,000 in general and 53,836,000 in industrial building and the capacities of lighting apparatus are 3,261,609 kW in general and 4,278,683 kW in industrial building. The ratio of Lighting apparatus is that fluorescent lamps are 56.9%, high intensity discharge lamps are 29.7%, and incandescent lamps are 12.1%.

  • PDF