• Title/Summary/Keyword: electrical resistance

Search Result 4,931, Processing Time 0.035 seconds

Fatigue damage detection of CFRP using the electrical resistance change method

  • Todoroki, Akira;Mizutani, Yoshihiro;Suzuki, Yoshiro;Haruyama, Daichi
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.4
    • /
    • pp.350-355
    • /
    • 2013
  • Electrical resistance change measurements were performed, to detect fatigue damage of a quasi-isotropic CFRP and cross-ply CFRP laminates. A four-probe method was used to measure the exact electrical resistance change. A three-probe method was used to measure the electrical contact resistance change, during long cyclic loading. The specimen side surface was observed using a video-microscope to detect damage. The measured electrical resistance changes were compared with the observed damage. The results of this study show that the electrical resistance increase of the quasi-isotropic laminate was caused by a delamination crack between ${\pm}45^{\circ}$ plies. Matrix cracking caused a small electrical resistance increase of the cross-ply laminate, but the decreased electrical resistance caused by the shear-plastic deformation impedes matrix-cracking detection.

Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants (목본식물 형성층 전기저항에 영향을 주는 환경 요인)

  • Kim, Dong-Uk;Kim, Min-Soo;Lee, Bu-Yong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.3
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

Influence of Acupuncture Stimulation on Electrical Resistance under Adiaphoresis Induced by Regional Anaesthesia (국소마취에 의한 발한 억제 상태에서 침자극이 인체 전기 저항에 미치는 영향)

  • Park, Kyung-Mo
    • Journal of Acupuncture Research
    • /
    • v.17 no.4
    • /
    • pp.130-138
    • /
    • 2000
  • Objectives : When sweating factor is excluded, to know the influence of acupuncture stimulation on electrical resistance. Methods : Regional anaesthesia(Lidocane 2%, 1ml, Subcutaneous injection) is applied to measured regions, 4cm round area including left Neiguan P6. So we can make adiaphoresis. Before and after acupucnture stimulation to Laogong P8, we measured the electrical resistance of anesthetized left Neiguan P6, anesthetized non-acupoint, normal left Ximen P4, and normal right Neiguan P6. For measurment, we use the 1.2V, DC system that has 100$k{\Omega}$ internal resistance Results : Under the adiaphoresis, Acupuncture stimulation makes the significant decrease of electrical resistance. In normal regions, so does it. Conclusions : When the acupuncture stimulation is applied to human boby, the decrease of electrical resistance is due not only to sweat secretion but also to other internal resistance.

  • PDF

Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul;Kim, Jae Ho
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.405-417
    • /
    • 2020
  • Background: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. Methods: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets' conductor surface and content, insulator weight, and thermal deformation temperature. Results: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 ℃. In relation to the installation year (30 years), insulation resistance decreased from 70 ℃, which is as much as 40 ℃ lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. Conclusion: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 ℃ of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 ℃. It is necessary to manage electrical socket outlets that have been installed for a long time.

Influence of heat treatments on electrical properties of ZnO films grown by molecular-beam epitaxy

  • O, Dong-Cheol;Kim, Dong-Jin;Bae, Chang-Hwan;Gu, Gyeong-Wan;Park, Seung-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.34-34
    • /
    • 2010
  • We report on the influence of heat treatments on the electrical properties of ZnO films grown by molecular-beam epitaxy. We note that the electrical resistance of the ZnO films is significantly changed by the heat treatments: the electrical resistance increases with the increase of ambient temperature, but above a critical temperature the resistance decreases with the increase of temperature, irrespective of ambient gases. On the other hand, it is found that the large amount of photocurrent is generated in the ZnO films, exposed to white sources: the photocurrent decreases with the increase of the obtained resistance, and the current increases with the decrease of the resistance. Also, it is shown that the X-ray diffraction linewidth of the ZnO films is significantly decreased by the heat treatments. These indicate that the increase/decrease of the electrical resistance is ascribed to the annihilation/formation of the residual donor-type defects in the ZnO films by the heat treatments. It is suggested that the increase of the electrical resistance is due to the annihilation of Zni-complex defects, while the decrease of the electrical resistance is due to the formation of VO-complex defects.

  • PDF

Optimization for Permeability and Electrical Resistance of Porous Alumina-Based Ceramics

  • Kim, Jae;Ha, Jang-Hoon;Lee, Jongman;Song, In-Hyuck
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.5
    • /
    • pp.548-556
    • /
    • 2016
  • Recently, porous alumina-based ceramics have been extensively applied in the semi-conductor and display industries, because of their high mechanical strength, high chemical resistance, and high thermal resistance. However, the high electrical resistance of alumina-based ceramics has a negative effect in many applications due to the generation of static electricity. The low electrical resistance and high air permeability are key aspects in using porous alumina-based ceramics as vacuum chucks in the semi-conductor industry. In this study, we tailored the pore structure of porous alumina-based ceramics by adjusting the mixing ratio of the starting alumina, which has different particle sizes. And the electrical resistance was controlled by using chemical additives. The characteristics of the specimens were studied using scanning electron microscopy, mercury porosimetry, capillary flow porosimetry, a universal testing machine, X-ray diffraction, and a high-resistance meter.

A Study on the Insulation Resistance Measurement Technique for Electrical Safety of Green Car (친환경자동차의 전기안전을 위한 절연저항 측정에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon;Moon, Hyun-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.597-601
    • /
    • 2009
  • Green car such as a hybrid electrical vehicle and fuel cell vehicle is developed as a commercial target. UN/ECE/WP29 is developing GTR of HFCV and establishing the regulation and standard of electrical safety by ELSA. The regulation and standard about Electrical safety of vehicle are prescribed in ISO, UN/ECE, FMVSS, Japanese Attachment and so on, in case of insulation resistance is referred to keep more than 100/Vdc, 500/Vac. However, accurate method to measure insulation resistance agreeable to structure of vehicle does not exist now, it is actually that correctness of measurement drops according to the feature of battery and fuel cell stack. In this paper, the method to measure insulation resistance for protection against electrical shock by direct contact or indirect contact in Green Car will be indicated by making a comparison between the insulation measurement in standard of electrical safety and the experiment results for HEV and HFCV.

The Analysis of missmatch with resistance on Si-PV module (결정질 태양전지 모듈 내부 저항의 Missmatch 분석)

  • Ji, Yang-Geun;Kong, Ji-Hyun;Kong, Gi-Hwan;Yu, Gwon-Jong;Won, Chang-Sub;Ahn, Hyung-Geun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, we test the electrical resistance of flat wire in the PV module. normally solar cell has two kind of flat wire(inter connection ribbon and bus bar ribbon). we found the phenomenon that has a unbalance with resistance when we make a wiling between of string. So, we measurement the resistance of flat wire each other. and analysis of missmatch with resistance between flat wires on PV module. next to survey of IR picture on missmatch flat wire samples for analyze of missmatch with current in the wire. and we perform IR test with solar cell that has a connection with flat wire for test the effect of missmatch resistance on solar cell. Finally we perform the Dark I-V test for survey of effect by the unbalance of resistance. By the result of Dark I-V test, the series resistance of existing connection sample is large more then innovated connection sample.

  • PDF

Behavior of the Temperature Coefficient of Resistance at Parallelly Connected Resistors (병렬로 접속된 저항체에서 저항온도계수의 거동)

  • Lee, Sunwoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.2
    • /
    • pp.98-101
    • /
    • 2018
  • In this paper, we discuss the fabrication of metal alloy resistors. We connected them in parallel to estimate their resistance and temperature coefficient of resistance (TCR). The fabricated resistors have different resistances, 5 and $10{\Omega}$ and different TCRs, 50 and $200ppm/^{\circ}C$. Each resistor was confirmed to have the correct atomic composition through the use of energy dispersive X-ray (EDX). The resistors' electrical properties were confirmed by measuring resistance and TCR. The resistance and TCR of the resistors connected in parallel were estimated through the increase in resistance due to the increase in temperature, and were compared with the measured values. We are confident that this TCR estimation technique, which uses the increase in resistance due to temperature, will be very useful in designing and fabricating resistors with low and stable TCR.

Analysis of Electrical Contact Resistance Model in Multi-Contact of Tribological Elements (트라이볼로지 기소의 멀티접촉에서 전기접촉저항 모델해석에 관한 연구)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.12 no.4
    • /
    • pp.52-59
    • /
    • 1996
  • The results of the electrical contact conductivity of multi-contact spots accounting the surface roughness and the non-conductive films of different origins such as air, water, cutting oil, and machining oil are presented. The array of metal spheres compressed between two flat plates has been used for simulation of the contact behavior of multiple contact of solids, under normal loading. Measurement of electrical contact resistance has been made using the equipment providing the adequate accuracy in the range of micro Ohms. The data on electrical contact resistance have been compared with theoretical predictions using the multiple contact model of constriction resistance. The effect of single spot number and array on conductivity of contact has been evaluated. The results of the experiments show that the contact resistance are closely related to the number of loading cycles, form of surface roughness, and presence of non-conductive films that reduce the size of the real electrical contact spots.