• Title/Summary/Keyword: electronic eye

Search Result 180, Processing Time 0.041 seconds

Optical Model of a Human Eye's Crystalline Lens Based on a Three-layer Liquid Lens

  • Kong, Meimei;Chen, Xin;Yuan, Yang;Zhao, Rui;Chen, Tao;Liang, Zhongcheng
    • Current Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.177-180
    • /
    • 2019
  • Based on liquid-lens technology and our previous findings on the optical model of the Chinese eye, the liquid lens is applied in the research of the crystalline-lens optical model. Theoretical models of three-layer liquid lenses are built with COMSOL software, and the effect of voltage on the shape of the interface between two liquids is analyzed. By polynomial fitting, different equations describing the interface shape are set up under different voltages. Finally, the optical system of the human eye with a three-layer liquid lens is built and analyzed with Zemax optical design software, and moreover the optical system models of emmetropia, myopia, and hyperopia are presented. This method to build a model of the human eye with a variable-focus liquid lens can provide a novel idea for more practical human-eye models for clinical regulation and control in the future.

Aspects of a head-mounted eye-tracker based on a bidirectional OLED microdisplay

  • Baumgarten, Judith;Schuchert, Tobias;Voth, Sascha;Wartenberg, Philipp;Richter, Bernd;Vogel, Uwe
    • Journal of Information Display
    • /
    • v.13 no.2
    • /
    • pp.67-71
    • /
    • 2012
  • In today's mobile world, small and lightweight information systems are becoming increasingly important. Microdisplays are the base for several near-to-eye display devices. The addition of an integrated image sensor significantly boosts the range of applications. This paper describes the base-building block for these systems: the bidirectional organic light-emitting diode microdisplay. A small and lightweight optic design, an eye-tracking algorithm, and interaction concepts are also presented.

A Driver's Condition Warning System using Eye Aspect Ratio (눈 영상비를 이용한 운전자 상태 경고 시스템)

  • Shin, Moon-Chang;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.349-356
    • /
    • 2020
  • This paper introduces the implementation of a driver's condition warning system using eye aspect ratio to prevent a car accident. The proposed driver's condition warning system using eye aspect ratio consists of a camera, that is required to detect eyes, the Raspberrypie that processes information on eyes from the camera, buzzer and vibrator, that are required to warn the driver. In order to detect and recognize driver's eyes, the histogram of oriented gradients and face landmark estimation based on deep-learning are used. Initially the system calculates the eye aspect ratio of the driver from 6 coordinates around the eye and then gets each eye aspect ratio values when the eyes are opened and closed. These two different eye aspect ratio values are used to calculate the threshold value that is necessary to determine the eye state. Because the threshold value is adaptively determined according to the driver's eye aspect ratio, the system can use the optimal threshold value to determine the driver's condition. In addition, the system synthesizes an input image from the gray-scaled and LAB model images to operate in low lighting conditions.

An Analysis of Cross-eye Characteristics for Electronic Protection of Radar (레이다의 전자 보호용 위상정합 특성 분석)

  • Chae Gyoo-Soo;Lim Joong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.1
    • /
    • pp.52-56
    • /
    • 2006
  • This paper presents a cross-eye characteristics of multi-path wave scattering. Cross-eye method uses the phase differences of multi signals and is used fur electronic protection. When a signal is propagated from transmitter to receiver on the ground surface, direct wave and reflected wave signals are combined in front of the receiving antenna with different phases. To calculate and control the amplitude and phase of reflected signal, we have developed a cross eye electronic protection method for radar system and studied the variation of electric power density.

  • PDF

Red-Eye Removal Using an Inpainting Method (인페인팅 기법을 이용한 적목현상 제거)

  • Yoo, Seung-Hwan;Park, Rae-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.365-366
    • /
    • 2007
  • In this paper, a novel correction method of red-eye effect is proposed. Conventional methods simply reduce red components in red-eye regions, not considering the expanded size of a pupil, thus the correction results can be unnatural. In the proposed method, an exemplar-based inpainting method is used for reducing the pupil region and filling the iris texture instead. Experimental results show that the proposed method is effective and its correction results look more natural than those of conventional methods.

  • PDF

A Comparative Clinical Study on an Electronic Moxibustion with Acupuncture for Dry Eye Syndrome (건성안 증후군에 대한 전자뜸과 침의 효과 비교 임상연구)

  • Ji-Shik Park;Ji-Hoon Song;Min-Yeong Jung;Jung-Hwa Choi;Soo-Yeon Park
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.36 no.1
    • /
    • pp.64-77
    • /
    • 2023
  • Objectives : Recently, the number of patients with dry eye syndrome has been steadily increasing. However, established treatment for it does not yet exist. This study compared electronic moxibustion with acupuncture for patients with dry eye in terms of efficacy and safety. Methods : This trial was designed as an investigator-initiated, single-blinded, comparative, randomized controlled trial. Thirty patients with dry eye were randomized to the electronic moxibustion treatment group(EMG) or the acupuncture treatment group(AG) in equal proportion. The participants who assigned to the EMG were treated with electronic moxibustion to ten acupoints including both sides of BL2, GB14, TE23, and LI4 for 12 minutes. The participants who were assigned to the AG were treated with acupuncture to the same acupoints for 15 minutes. Over 4 weeks, each intervention was carried out twelve times in total. The primary outcome was the ocular surface disease index(OSDI). The secondary outcomes were the subjective symptoms visual analog scale(VAS), quality of life(QoL), Schirmer I test(SIT), and general assessment. Adverse events and vital signs were also investigated for safety assessment. Results : In intragroup comparisons, both the EMG and the AG significantly improved the OSDI scores, the subjective symptoms VAS scores, the QoL scores, and the SIT results after 4 weeks of the trial. However, there were no statistical differences in intergroup comparisons between the two groups after 4 weeks. The safety of electronic moxibustion and acupuncture was confirmed by no occurrence of serious adverse events. Conclusions : Both electronic moxibustion and acupuncture were effective for dry eye syndrome, and they were safe. Electronic moxibustion and acupuncture can be used for dry eye syndrome as equivalent treatments.

Eye-Gaze Interaction On Computer Screen Evaluation

  • Ponglangka, Wirot;Sutakcom, Udom
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.84-88
    • /
    • 2005
  • Eye gaze positions evaluation on computer screen uses the human eye as an input device for computer systems is that it gives low resolution. We proposes a method to determine the eye gaze positions on the screen by using two-eye displacements as the information for mapping, and the perspective projection is applied to map the displacements to a position on a computer screen. The experiments were performed on 20 persons and a 17-inch monitor is used with the screen resolution of 1024x768 pixels. Gaze detection error was 3.18 cm (RMS error), with screen is divided into 5x8 and 7x10 positions on a 17-inch monitor. The results showed 100% and 96% correction, respectively.

  • PDF

Implementation to human-computer interface system with motion tracking using OpenCV (OpenCV를 이용한 눈동자 모션인식을 통한 의사소통 시스템 구현)

  • Heo, Seung Won;Lee, Seung Jun;Lee, Hee Bin;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.700-702
    • /
    • 2018
  • In this abstract, introduces a system that enables communication by tracking the pupils of Lou Gehrig's disease patients who are unable to move their bodies. Face and eye pupil tracking perform using OpenCV, and eye movement recognition and character selection by eye movement is obtained using Python. In this paper, you will use the webcams, track your eyes, determine eye movements based on the coordinates of your pupils, and print characters that meet your preferences. It can easily output text messages using Bluetooth.

  • PDF

The Retrospective Study of 463 Patients who had Funduscopy Examination at Korean Medicine Ophthalmology (한방 안과에 내원하여 안저 검사를 시행한 환자 463명에 대한 후향적 연구 보고)

  • Lee, Ma-Eum;Jeong, Mi-Rae;Kim, Chul-Yun;Kwon, Kang;Seo, Hyung-Sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.33 no.2
    • /
    • pp.1-11
    • /
    • 2020
  • Objectives : The purpose of this study was to analyze and report status of Korean Medicine Ophthalmology patients who did funduscopy examination. Through this, we hope that the development of our diagnosis and treatment. Methods : From June 1, 2010 to May 31, 2019, Based on the electronic medical records of patients who had funduscopy examination at Korean Medicine Ophthalmology, Busan University Korean Medicine Hospital, the gender, age, visiting motives and paths, diagnosis, examination number of years, other eye examinations and treatments method were summarized and analyzed. Results : 463 patients were able to check the electronic medical records. They were 283 females and 180 males. The mean age of the patients was 51.5 years and elderly patients who 50s and 60s were 49.3% of whole patients. The most common motives for Korean Medicine Ophthalmology visitation was 'combination treatment with other department in Korean Medicine Hospital'. Outer eye diseases were 283 cases, inner eye diseases were 198 cases. Dry eye syndrome, asthenopia, visual discomfort, conjunctivitis, and eye discomfort were most common in the outer eye diseases. Cataracts, Vitreous floater, Macular Degeneration, Glaucoma and Ocular Pain were most common in the inner eye disease. The most common parts of outer eye diseases were Conjunctival, lacrimal gland, paralytic, corneal, eyelid and front uveal, scleral disease and then in inner eye diseases parts, Retinal, lens, vitreous, glaucoma, optic nerve, behind uveal, choroid disease were most common. The number of funduscopy examination was ups and downs. Herbal medicine was the most common used. Conclusions : The funduscopy examination is essential for diagnosis and treatment of eye disease. We hope that the use of fundus examination and other ophthalmologic examination will be expanded soon in Korean Medicine Ophthalmology.

Implementation of saccadic eye movement system with saliency map model (Saliency map 모델을 갖는 도약 안구 시각 시스템의 구현)

  • Cho, Jun-Ki;Lee, Min-Ho;Shin, Jang-Kyoo;Koh, Kwang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.52-61
    • /
    • 2001
  • We propose a new saccadic eye movement system with visual selective attention. Saliency map models generate the scan pathways in a natural scene, of which the output makes an attended location. Saccadic eye movement model is used for producing the target trajectories to move the attended locations very rapidly. To categorize human saccadic eye movement, saccadic eye movement model was divided into three parts, each of which was then individually modeled using different neural networks to reflect a principal functionality of brain structures related with the saccadic eye movement in our brain. Based on the proposed saliency map models and the saccadic eye movement model, an active vision system using a CCD type camera and BLDC motor was developed and demonstrated with experimental results.

  • PDF