• 제목/요약/키워드: end bearing capacity

검색결과 183건 처리시간 0.025초

SPT-N값에 따른 매입말뚝의 선단지지력 특성 연구 (Study on the Evaluation of End Bearing Capacity of Pre-Bored Piles for the SPT-N value)

  • 서동남;최상호;김진식;김성철;이동현;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.133-134
    • /
    • 2020
  • The equation of end bearing capacity is applied differently depending on the type of pile, construction method, and load characteristics considering the construction standards. The bearing capacity equation of the design standard is presented in various ways according to the design conditions such as construction method and ground condition, etc. but, It does not reflect the ground strength according to the SPT-N value of weathered rock. This study analyzed the trend of allowable tip bearing capacity by pile diameter through about 480 dynamic loading tests conducted for the construction/quality management of piles for the last 6 years since 2015. The equation for the ultimate end bearing capacity per unit area according to the SPT-N value is presented. The proposed formula of ultimate end bearing capacity per unit area can be applied in the range of 15,000kN/m2 to 30,000kN/m2. The proposed formula, which complements the existing formula, enables pile design and construction/quality management.

  • PDF

무리말뚝을 구성하는 개별말뚝의 선단지지력에 대한 실험연구 (Experimental Study on the End Bearing Capacity of the Pile in a Group Pile)

  • 나용수;이상덕
    • 한국지반공학회논문집
    • /
    • 제35권6호
    • /
    • pp.27-38
    • /
    • 2019
  • 균질한 지반에서 말뚝의 지지력은 선단지지력과 주변마찰력의 합이며, 사질지반에서는 주변마찰력이 선단지지력보다 우세한 것으로 알려져 있다. 다수의 말뚝을 근접하여 설치하는 무리말뚝에서는 말뚝 하나하나의 지지력이 말뚝 상호간 간섭에 의해 달라질 수 있으므로, 말뚝의 근접도에 따라서 선단지지거동과 주변마찰거동의 변화를 정확하게 파악하여 말뚝을 설계해야 한다. 따라서 본 연구에서는 주면마찰거동의 영향을 배제한 상태에서 무리말뚝의 선단지지거동을 측정하기 위해 크기가 일정한 원형 토조에서 여러 가지 직경과 깊이로 말뚝을 설치하고 상대밀도가 균일한 모래지반을 조성한 후 선단지지력을 측정하여 무리말뚝의 근접도에 따른 영향을 확인하였다. 연구결과 말뚝의 선단저항력은 비교적 뚜렷하게 극한값을 나타냈다. 말뚝의 극한선단지지력은 주면마찰력과 말뚝의 직경에 의한 영향을 적게 받으며, 말뚝관입길이가 깊어질수록 일정한 값에 수렴하였다. 또한, 무리말뚝에서 인접한 말뚝이 말뚝 직경만큼 서로 이격되어 있으면 인접말뚝의 영향이 거의 없었다.

선단지지된 항타개단강관말뚝의 축하중전이거동 (Axial Load Transfer Behavior for Driven Open-ended End bearing Steel Pipe Pile)

  • 임태경;정성민;정창규;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.589-596
    • /
    • 2002
  • In this study, static pile load tests with load transfer measurement were accomplished in the field. Yield pile capacity (or ultimate pile capacity) determined by load-settlement-time relationship was determined and axial load transfer behavior was analyzed. In the test for the four test piles were behaved as end bearing pile but ratios of skin friction to total pile capacity were 27%∼33%.

  • PDF

매입말뚝공법의 지지력 예측식 개선에 관한 연구 (A Study on the Improvement of Bearing Capacity Prediction Equation for Auger-drilled Piling)

  • 최도웅;한병권;서영화;조성한
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.382-389
    • /
    • 2002
  • Recently, auger-drilled piling has been widely used in urban area to reduce the air pollution and noise. But this construction method that its basic theory was introduced from Japan may be changed depending on the each piling company and construction field condition. Therefore, the design code and management method for auger-drilled piling is not defined yet. Especially, the lack of research on the bearing capacity of auger-drilled piling leads to the absence of rational bearing capacity prediction equation. This paper presents the optimum design code and economical construction method of the auger-drilled piling by proposing the new bearing capacity prediction equation based on the site specific soil types and construction conditions. In this paper, existing bearing capacity prediction equations and current pile load tests were compared. And the end bearing capacity and skin friction characteristics were also analyzed by comparing the results of CAPWAP. From the results of analysis, a reliable bearing capacity prediction equation considered soil types is proposed.

  • PDF

암반에 설치된 현장타설말뚝의 극한선단지지력에 관한 연구 (A Study on the Ultimate End Bearing Capacity of Drilled Shafts in Rocks)

  • 정상섬;이재환;김도현
    • 한국지반공학회논문집
    • /
    • 제29권11호
    • /
    • pp.5-15
    • /
    • 2013
  • 본 연구에서는 Hoek-cell을 이용한 실내모형실험 및 개별요소해석을 수행하여 말뚝의 직경, 암반의 강도와 불연속면 조건이 암반에 근입된 현장타설말뚝의 선단부 거동에 미치는 영향을 분석하였다. 이를 통해 영향인자를 선정하였고, 실제 현장재하시험 데이터베이스를 구축하여 암반근입 현장타설말뚝의 극한선단지지력 예측식을 제안하였다. 또한, 제안된 극한선단지지력 산정식을 현장재하시험 결과와 비교 분석하여 그 적용성을 검증하였다. 그 결과, 시험말뚝이 근입된 암반의 불연속면 특성을 고려하지 못하고 일축압축강도만을 이용하여 극한선단지지력을 예측하는 기존 제안식들이 일부 재하시험 결과를 과도하게 예측하는 데 비해, 본 연구의 제안식은 선단부 거동 영향인자를 반영하여, 현장말뚝의 극한선단지지력을 적절히 예측하고 있음을 확인할 수 있었다.

Chord bearing capacity in long-span tubular trusses

  • Kozy, B.;Boyle, R.;Earls, C.J.
    • Steel and Composite Structures
    • /
    • 제6권2호
    • /
    • pp.103-122
    • /
    • 2006
  • The capacity of tubular truss chords subjected to concentrated reaction forces in the vicinity of the open end (i.e., the bearing region) is not directly treated by existing design specifications; although capacity equations are promulgated for related tubular joint configurations. The lack of direct treatment of bearing capacity in existing design specifications seems to represent an unsatisfactory situation given the fact that connections very often control the design of long-span tubular structures comprised of members with slender cross-sections. The case of the simple-span overhead highway sign truss is studied, in which the bearing reaction is applied near the chord end. The present research is aimed at assessing the validity of adapting existing specifications' capacity equations from related cases so as to be applicable in determining design capacity in tubular truss bearing regions. These modified capacity equations are subsequently used in comparisons with full-scale experimental results obtained from testing carried out at the University of Pittsburgh.

풍화대소켓 현장타설말뚝의 극한단위선단지지력과 원위치 지반조사방법들과의 상관관계 분석 (An Analysis on Co-relationships Between In-situ Investigation Methods and End Bearing Capacity of A Drilled Shaft Socketed into the Weathered Zone)

  • 최용규;권오성;이종성;최성순;정성민
    • 대한토목학회논문집
    • /
    • 제30권2C호
    • /
    • pp.95-107
    • /
    • 2010
  • 일반적으로 암반에 소켓된 현장타설말뚝기초의 선단지지력은 일축압축강도를 이용하여 산정하고 있다. 그러나, 풍화대 지반에서는 불교란시료의 채취가 어려워 일축압축강도를 확인하는 것이 곤란하므로 기존 지지력산정공식을 사용할 수 없다. 따라서 본 연구에서는 풍화대 지반에서 수행할 수 있는 원위치시험들(SPT, DCPT, PMT, BST)의 특성치와 현장타설말뚝의 선단지지력과의 관계를 말뚝선단부에 인접한 5개의 구간들(선단부, 선단~하부1D, 선단~하부2D, 상부1D~하부1D, 상부1D~하부2D)에 대하여 분석하였다. 그 결과 DCTP의 결과가 가장 신뢰성 있는 상관관계를 나타내었다. 또한 DCPT를 이용한 선단지지력의 설계도표를 제안하였다.

선단유압재하시험을 이용한 단층파쇄대에 설치된 대구경 현장타설말뚝의 선단지지력 측정 사례 (Case Studiy on Measurement of End Bearing Capacity for Large Diameter Drilled Shaft Constructed in Fault Zone using Loading Test)

  • 정창규;김태훈;정성민;황근배;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.74-81
    • /
    • 2004
  • In this study, static end loading tests with load transfer measurement were accomplished for large diameter drilled shaft constructed in fault zone. Yield pile capacity (or ultimate pile capacity) from load-settlement curve was determined and axial load transfer behavior was measurd. The end bearing capacity was increased 2 times due to grouting the toe ground under pile base.

  • PDF

사질토에 있어서 말뚝의 선단부 지지력 (End Bearing Capacity of a Pile in Cohesionless Soils)

  • 이명환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1988년도 학술세미나 강연집
    • /
    • pp.71-123
    • /
    • 1988
  • The aim of this paper is to examine the end bearing capacity of a pile in cohesionless soils. The ode of failure of soil due to pile installation is assumed from experimental observation of actual soil deformation. A new solution is proposed complying with the assumed mode of failure by employing the theory of cavity expansion. The effect of curvature of failure envelope is studied in relation to tile proposed solution. The influence of a curved failure envelope becomes larger with increasing degree of curvature and the level of confining stress. This effect in some cases or reduce the end bearing capacity by tore the 80 percent compared with that given by a straight failure envelope. For practical application of tile proposed solution, the method of determining the average volume change in the plastic zone is re-evaluated. The proposed solution is confirmed by comparing the theoretical values with experimental results obtained from model pile tests in a calibration chamber. The comparison shows that the proposed solution provides a reasonable prediction of end bearing capacity for both weak and strong grained soils.

  • PDF

직경 600mm PHC 매입말뚝의 동재하시험을 통한 허용 지지력 평가 (Evaluation of Allowable Bearing Capacity of 600 mm Diameter Preboring PHC Piles Using Dynamic Load Test)

  • 우규성;박종배;서미정;이종섭
    • 한국지반공학회논문집
    • /
    • 제32권11호
    • /
    • pp.61-72
    • /
    • 2016
  • 구조물의 고층화가 진행됨과 동시에 효율적인 기초 설계를 위해 대구경 PHC 말뚝의 사용이 증가하고 있으며, 특히 600mm PHC 말뚝의 사용량이 급증하고 있다. 본 연구에서는 현재 사용되고 있는 설계법의 적정성을 평가하기 위하여, 직경 600mm PHC 매입말뚝에 대하여 수행된 46본의 동재하시험 결과를 분석하였다. 선단지지력은 초기항타시험의 결과를 이용하였으며 주면마찰력은 재항타시험 결과를 이용하여 각각의 허용지지력을 산정하였다. 동재하시험으로부터 산정된 허용지지력을 현재 사용되는 설계법으로 평가된 허용지지력과 비교하였다. 분석결과, 동재하시험으로 산정된 허용선단지지력은 대부분의 말뚝에서 설계기준보다 컸지만, 허용주면마찰력은 많은 말뚝에서 설계기준보다 작게 산정되었다. 이와 같은 큰 선단지지력과 작은 주면마찰력은 천공장비의 성능 향상 및 굴착 깊이의 증가 때문이며 이로 인해 전체지지력에서 선단지지력이 차지하는 비율이 높아졌기 때문이다.