• Title/Summary/Keyword: explosion proof

Search Result 78, Processing Time 0.037 seconds

A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities (방폭설비 성능유지 실태분석을 통한 관리방안 연구)

  • Kwon, Yong Jun;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.

A Study on the Method to Avoid the Gas Group IIC Equipment of Explosion Proof Electrical Equipment Adjacent to the Source of Release of Hydrogen Handling Facility (수소 취급설비의 누출원에 인접한 방폭전기기기의 가스그룹 IIC 기기 회피 방안에 관한 연구)

  • BYUN, YOON SUP
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.383-390
    • /
    • 2022
  • Appropriate explosion proof electrical equipment should be installed in hazardous areas. In areas where hydrogen is handled, explosion proof electrical equipment adjacent to the hydrogen handing facility must be reviewed for selection of gas group IIC (or IIB+H2) equipment. When selecting explosion proof electrical equipment for the flammable substance handling facility in areas where hydrogen and flammable substance are handled, the method to avoid gas group IIC (or IIB+H2) equipment has been suggested by using the operating pressure of the hydrogen handling facility. When the operating pressure of the outdoor hydrogen handling facility is 1.065 MPa or less, it has been confirmed that there is no need to install gas group IIC (or IIB+H2) equipment for the flammable substance handling facility adjacent to the hydrogen handling facility. And the method of selecting explosion proof electrical equipment for the flammable substance handling facility has been suggested as a flowchart, so it will be able to be utilized when selecting appropriate explosion proof electrical equipment.

A Study on the Light Weight Hand Lamp for Explosion-Proof Type (휴대형 방폭등의 경량화 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • For lighting of dark and hazardous workplace such as compartment of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, we developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a prototype which consisted of lamp fixture and high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Occupational Safety and Health Agency. And more, we surveyed the explosion protection technology of a light weight hand lamp, and suggested the advantage/disadvantage to apply lighting of hand lamp about economical aspect.

Explosion-proof Properties of High Strength Steel Fiber Reinforced Concrete made with Contents of Steel Fiber (섬유혼입율 변화에 따른 고강도 섬유보강 콘크리트의 방폭특성)

  • Han, Cheon-Goo;Kim, Seong-Soo;Park, Goo-Byeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.129-136
    • /
    • 2000
  • In the side of military purpose, the explosion proof concrete, which contributes to protect the military facilities from damages due to the explosion of bomb and to maintain their shapes, is required to develop, Therefore. in this paper, mechanical and explosion-proof properties of concrete are tested under various steel fiber contents and member size. According to the experimental results, compressive, tensile and flexural strength gain higher levels with an increase in fiber contents. It shows that energy bearing capacities are higher with an increase in fiber contents. Especially. it is confirmed that slurry infiltrated fiber concrete(SIFCON) gains high strength and has high energy bearing capacities. SIFCON is expected to be applied in the construction of explosion proof structures.

  • PDF

A Study on the Development of Explosion Proof ESD Detector and Intrinsic Safety Characteristics Analysis (방폭구조 ESD Detector 개발 및 본질안전 특성 분석에 관한 연구)

  • Byeon, Junghwan;Choi, Sang-won
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • Article 325 (Prevention of Fire Explosion due to Electrostatic) of the Rule for Occupational Safety and Health Standard specifies that in order to prevent the risk of disasters caused by static electricity, fire, explosion and static electricity in the production process, However, in order to do this, it is absolutely necessary to use a pre-detection technology and a detector for antistatic discharge prediction, which is a precautionary measure by static electricity in a fire / explosion hazard place, but in Korea, And there is no technical standard for the application of the technology of the explosion proof structure of the related equipment. Research methods include domestic and overseas electrostatic discharge detection technology and literature investigation of related equipment explosion proofing technology, domestic and foreign electrostatic discharge detection device production and use situation investigation, advanced foreign technology data analysis and benchmarking. In particular, we sought to verify the results of empirical experiments using electrostatic discharge detection technology through sample purchase and analysis of related major products, development of optimization technology through prototype production, evaluation, and supplementation, and expert knowledge through expert consultation. The results of this study were developed and fabricated two prototypes of electrostatic discharge detector based on the technology / standard related to electrostatic discharge detection technology in Korea and abroad through development of electrostatic discharge detection technology and development and production of detector. In addition, based on the development of electrostatic discharge detection technology, we developed an intrinsic safety explosion proof ib class explosion proof technology applicable to the process of using and handling flammable gas and flammable liquid vapor and combustible dust. In the case of the over voltage and minimum voltage are supplied to the explosion-proof structure ESD detector, check the state of the circuit and the transient and transient currents generated by the coil and capacitor elements during the input and standby of the signal pulse voltage. Explosion-proof equipment-Part 11: Intrinsically safe explosion proof structure The comparative evaluation with the reference curve in Annex A of "i" confirms that the characteristics of the intrinsically safe explosion protection structure are met.

The Explosion-proof Performance of HPFRCC According to Fiber Combination and Mixing Ratio (섬유조합 및 혼입율 변화에 따른 HPFRCC의 방폭성능)

  • Lee, Jea-Hyeon;Lee, Jong-Tae;Jung, Woung-Seon;Jo, Sung-Jun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.88-89
    • /
    • 2017
  • Due to the increase in the usage of explosive materials and terrorism, the interest towards the superior explosion protective HPFRCC has risen. In existing research, the optimum ratio for solving the problematic problems such as the optimum fiber incorporation rate and the self-shrinkage crack of HPFRCC had been derived. However, there had been few or even no research upon how effective HPFRCC would perform protective explosion-proof in actual explosion. Therefore, this research compared the explosion-proof performance of HPFRCC according to fiber commination and mixing ratio. As a result, the combination of steel fiber and organic fiber showed excellent flow and strength, and it also improved the explosion resistance.

  • PDF

An Study on control of explosion pressure in enclosure (내압 폭발 압력 조정에 관한 연구)

  • Kim, Hong-Sik;Oh, Dae-Hee;Oh, Kyu-Hyung;Choi, Beom-Shik;Lee, Sung-Eun;Moon, Young-Gil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.189-193
    • /
    • 2008
  • A Control variables of explosion pressure in enclosure are a type of explosive gas, concentration of mixture, open area in enclosure. In this study, be performed to test inner explosion pressure of Blast Proof Door by the control variables of explosion pressure. and this real explosion test of Blast Proof Door have a good point in test of the against pressure method that can be obtained dynamic pressure or not static pressure.

  • PDF

Constructional Properties and Evaluation Methods of the Non-Incendive Type of Explosion-Proof Electrical Apparatus (비점화(非點火)(Non-Incendive)형(型) 방폭(防爆) 전기기기(電氣機器)의 구조특성(構造特性) 및 평가방법(評價方法))

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.110-113
    • /
    • 1994
  • In the hazardous areas where explosive substances in the form of gases, vapor or mists exist, electrical apparatus and installations must be of explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, six types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, and special types. If electrical apparatus are made of explosion-proof construction in a way other than five above-mentioned types, and their performance is tested and approved by the reponsible authorities, they may be categorized as special type apparatus. In this paper, we introduced a special type of explosion-proof electrical apparatus, called non-incendive type, and presented its constructional requirements. We also investigated evaluation methods of non-incendive type apparatus to assure the explosion-proof performance, and proposed a new classification method of hazardous areas using probabilistic concept.

  • PDF

Development of a Light Weight Hand Lamp of Explosion-Proof Type (휴대용 방폭형 작업등의 경량화 연구)

  • 최상원;이관형;김명섭;임의수
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.135-142
    • /
    • 1997
  • For lighting of dark and hazardous workplaces such as compartments of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, ire developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a Prototype which consisted of lamp fixture and low/high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Industrial Safety Corporation.

  • PDF

A Study on the development of Explosion-proof type's the terminal box of the ventilator with the control of wind volume and operating time (풍량 및 운전시간 제어 방폭 배풍기 인버터 단자함 개발에 관한 연구)

  • Yoo, DongJoo
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.187-192
    • /
    • 2018
  • This thesis is about the study of inverter terminal boxes in a explosion proof type exhaust fan that can control wind volume and operating time. In Korea, there is no ventilator to adjust the amount of wind and operating time when working in poor conditions. The purpose of the project is to create a explosion terminal box that can control the operating time and wind speed of a suitable explosion ventilator in hazardous environments. The two explosion-proof switches allow the operation time to be driven 1 hour, 3 hours and continuous time, and the speed of the induction motor rotation was set in 3 stages at 2000 rpm, 2600 rpm and 3000 rpm to control the volume. The tested motor used a half-horsepower barrier three-phase induction motor and a full-bridge inverter to set the desired flow rate and operating time.