• Title/Summary/Keyword: exposed concrete

Search Result 897, Processing Time 0.022 seconds

A Study on the Quality Properties of Exposed High Fluidity Concrete using Fly Ash and Limestone Powder (플라이애시 및 석회석 미분말을 사용한 고유동 노출 콘크리트의 품질특성에 관한 연구)

  • Choi, Yun-Wang;Oh, Sung-Rok;Kim, Ji-Hoon;Kim, Kyung-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.67-75
    • /
    • 2013
  • Recently, the interest is increasing about the exposed concrete, accordingly, exposed concrete is expanding the use. However, concrete structures is difficult to apply the general concrete for exposed concrete, due to complex section and compact reinforcement, increasingly. Therefore, in this paper, for application of high fluidity concrete as exposed concrete, exposed high fluidity concrete using fly ash and lime stone powder was manufactured and observed quality property(fluidity properties, mechanical properties and Surface Properties) of exposed high fluidity concrete. The experiments are based on the OPC and LSP10, was evaluated Impact on the quality of concrete according to mixing ratio of FA(0, 10, 15 and 20). As a result, fluidity properties, mechanical properties and Surface Properties of exposed high fluidity concrete were satisfied to requirement conditions, fluidity and surface finishability was improved depending on mix of fly ash and limestone powder. Through this, we utilize of basic research data for development of high fluidity concrete for exposed concrete.

A Sensibility Evaluation Study on Interior Space of Exposed Concrete Finish - Focused on the Kim Ok Gil Memorial Hall Restaurant - (노출 콘크리트 마감의 실내 공간 감성평가 연구 - 김옥길 기념관 레스토랑을 중심으로 -)

  • Lee, Jisun;Jung, Hyun-Won;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.5
    • /
    • pp.121-129
    • /
    • 2016
  • With the ingenious properties of unconstrained formativeness and frank expression of materiality the exposed concrete became popular with numerous architectures. The application of the exposed concrete has expanded to indoor environments such as commercial and residential spaces beyond the building exteriors with the uncompromising nature of its materiality. The purpose of this study is to conduct sensibility evaluation of the exposed concrete finish in interior spaces. The sensibility evaluation is conducted through a survey on a set of space models of the exposed concrete finish. The three rendered space models were evaluated by emotional vocabulary of 18 pairs of words. The result were as follows: First, the emotions derived from the exposed concrete finish are 'modern', 'cold', 'simple', 'restrained', 'rough', 'dark', 'new', 'chic', 'familiar' and 'eco-friendly'. Second, three sets of space models with alternative materials on walls and floors in exposed concrete interior space showed clear difference in sensibility. A space with the exposed concrete finish on the floor, the walls and the ceiling showed the results of 'cold', 'dark', 'rational' and 'masculine'. In the exposed concrete finish environment with wood flooring 'comfortable', 'warm', 'bright' senses and with white paint finish on the wall 'bright', 'practical', 'ordinary' and 'restrained' senses were obtained. Third, all three images achieved senses of 'chic', 'modern', 'new', 'pleasant', 'environment friendly' and 'satisfactory'. The modernity and stylish expressions of the exposed concrete finish were kept with the application of different material finishes as well as complementing its cold and rough expressions with warmth and brightness.

Air-borne Chloride Content of Highway Bridges Exposed to Marine Environment (해양환경에 위치한 국내 고속도로 교량의 비래염분량 측정 결과)

  • 정해문;유환구;류종현;안태송;김수만;오병환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.743-748
    • /
    • 2002
  • Chloride ingress into concrete followed by reinforcement corrosion and deterioration of concrete structures is a major problem for many structures under chloride attacks. Large-scale concrete structures directly exposed to seawater such as SeoHae Grand Bridge are increasingly constructed along the coast in Korea. It is necessary to investigate the environmental conditions of concrete structures exposed to chloride attacks. In this study, the air-borne chloride contents of highway bridges exposed to marine environment in Korea were measured.

  • PDF

Study on the Exposed Concrete Construction Formwork According to Attachment Materials (거푸집 붙임재료에 따른 노출콘크리트 시공에 관한 연구)

  • Park, Se-Jun;Lee, Yun-Suk;Lee, Young-Do
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.223-224
    • /
    • 2016
  • Recent local advantages to improve the aesthetics of building materials connected with one of the trend of Exposed Concrete and Construction Method in various facilities and to diversify Showing a tendency to both application and development. This exposed concrete form of the features and materials is, the impact of large commercial viability and can consider I can apply to the surface of construction on a surface The diversification of the material was soon exposed directly linked to the varying aesthetics of concrete, and currently take advantage of the form of material is based on such important factor in our country Based on the concept of Exposed Concrete utilized by some construction site, design and be considered is very important elements of the put to practical use.

  • PDF

DESIGN MANAGEMENT FOR CONSTRUCTABILITY REVIEW OF HIGH QUALITY EXPOSED CONCRETE

  • Doo Won Hwang;Young woong Song;Yoon ki Choi;Dong Woo Shin;Jae Youl Chun
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.1154-1157
    • /
    • 2005
  • This report is to do design management for constructability review of high quality exposed concrete, which is used increasingly in recent. To secure systematic management at design phase, we reviewed each definition and work at each design phase, we define high quality exposed concrete, a part of architectural concrete, as "an exposed concrete which has well ordered joint & is in pursuit of smooth surface." We reviewed requirements and influential factor to obtain High quality finishing surface and compared construction process of high quality exposed concrete with that of other finishing method. Management method at each design phase for constructability review to meet additional works and requirements is presented.

  • PDF

Study on the surface characteristics of concrete walls by coating film of formwork (거푸집 코팅필름에 따른 콘크리트벽의 표면 특성 연구)

  • Lee, Yun-Suk;Seo, Ju-Yeong;Kim, Wan-Su;Lee, Young-Do
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.202-203
    • /
    • 2017
  • In this study, the concept of exposed concrete is basically considered and various expressions of concrete surface texture are verified variously. Based on this comparison, the characteristics of exposed surface of concrete according to the change of coating material applicable to formwork are compared and analyzed. I am trying to find a way to apply exposed concrete in a convenient way, In order to observe the characteristics of concrete exposed surface according to the form material, As the surface is smooth and tight, the surface condition of the concrete is smooth and the pore is small.

  • PDF

Quality Management of Exposed Concrete at Construction Phase (시공단계 노출 콘크리트 품질관리 방안)

  • Kim, Tae-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.164-165
    • /
    • 2016
  • To express the original texture of the concrete, exposed concrete finishing technique has been applied in many buildings. However, it is likely to cause quality problems after construction is completed. In addition, because of costs and time issues, reconstruction and maintenance works are difficult and ineffective. Therefore, step-by-step proactive quality management based on sufficient consensus among participants(client, designer, contractor) is very importatnt. This study analyzed factors causing low quality exposed concrete and quality contol points applied to 'A' headquarter construction project.

  • PDF

Pull-out Strengths of GFRP-Concrete Bond Exposed to Applied Environmental Conditions

  • Kabir, Muhammad Ikramul;Samali, Bijan;Shrestha, Rijun
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.69-84
    • /
    • 2017
  • This paper presents results of an experimental investigation on the behaviour of bond between external glass fibre reinforced polymer reinforcement and concrete exposed to three different environmental conditions, namely, temperature cycles, wet-dry cycles and outdoor environment separately for extended durations. Single shear tests (pull-out test) were conducted to investigate bond strengths (pull-out strengths) of control (unexposed) and exposed specimens. Effect of the exposure conditions on the compressive strength of concrete were also investigated separately to understand the effect of changing concrete compressive strength on the pull-out strength. Based on the comparison of experimental results of exposed specimens to control specimens in terms of bond strengths, failure modes and strain profiles, the most significant degradation of pull-out strength was observed in specimens exposed to outdoor environment, whereas temperature cycles did not cause any deterioration of strength.

A Study on the Defects of Exposed Concrete Finishing Work Using AHP (AHP기법을 활용한 노출콘크리트 마감공법 하자 도출)

  • Choi, Seongmi;Song, Yeongwoong;Lee, Kiseok;Yoo, Seonghoon;Choi, Yoonki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.4
    • /
    • pp.46-55
    • /
    • 2019
  • The exposed concrete has been widely used in building construction. Therefore, many researches are presented to secure a proper construction quality of exposed concrete. Low quality and management absence, however, still remained in construction fields. Thus, many studies have been conducted to improve the quality, but defects still occur in the exposed concrete finishing work. In this study, the causes of defects were analyzed by process in order to prevent the generation of defects and to enhance the need for integrated management to secure quality. In addition, a case study and AHP analysis have derived the importance of defects occurring in the exposed concrete finishing work. The study concluded that the occurrence of the exposed concrete finishing work needs to be managed throughout the process, not the management limited by one process, according to the causes of the existing defects, and integrated management is required to prevent defects and improve quality of exposed concrete finishing work.

Mock-up Test of Exposed Concrete Wall using Self Compacting Concrete (노출 구조물 벽체에 적용하기 위한 무다짐 콘크리트 실물모형 실험)

  • 김규동;이승훈;손유신;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.561-566
    • /
    • 2002
  • Recently, high quality exposed concrete is needed to achieve high quality surface for outer wall of the building. In this study, to solve above characteristic of the exposed concrete we selected self compacting concrete(SCC) and compared with normal concrete. So, we developed the SCC mix design and performed the semi mock-up test. Through this result, we performed the pilot test and mock-up test to check surface of outer wall and to measure formwork pressure As a result because SCC is better than normal concrete with respect to flowability and seggregation resistance SCC is suit to a exposed concrete needed high quality surface for outer wall of the building.

  • PDF