• 제목/요약/키워드: far-infrared radiation

검색결과 109건 처리시간 0.033초

옥외에서 원적외선 방사직물 착용시 온열생리반응 (Thermo Physiological responses of Far Infrared Ray Radiation Fabrics at outdoor in summer)

  • 송명견;안필자;최정화
    • 한국농촌생활과학회지
    • /
    • 제7권2호
    • /
    • pp.121-128
    • /
    • 1996
  • This study was performed to define the effects of Far Infrared Ray Radiation Fabrics as summer garments during outdoor work by human trial. One healthy male subject was volunteered for this study. Experimental garments consisted of three kinds of trousers (Cotton, Cotton/linen blended, Far Infrared Ray Radiation Fabric/wool blended) and basic garments (panty, socks, shirts, and dress shirts). The measurements were rectal temp., skin temp., microclimate inside clothing, heart rate, subjective sensation etc. The results were as follows : 1. Rectal temperature showed the lowest in Far Infrared Ray Radiation Fabrics among 3 garments. 2. Skin temperature (forehead, chest abdomen temp.) and mean skin temperature were lower in Far Infrared Ray Radiation Fabrics than in others, especially during early stage of work. 3. Heart rate showed lower value in Far Infrared Ray Radiation Fabrics than in others but there was no significance among the garments. 4. Humidity inside clothing and total weight loss showed the highest value in Far Infrared Ray Radiation Fabrics.

  • PDF

월경통(月經痛)에 대한 원적외선 방사 기능성 under inner-wear의 유용성 평가 (The evaluation of usefulness for far-infrared radiating under inner-wear on dysmenorrhea)

  • 조정훈;이경섭;윤영진
    • 대한한방부인과학회지
    • /
    • 제20권3호
    • /
    • pp.129-136
    • /
    • 2007
  • Purpose: We intended to observe the usefulness of far-infrared radiation functional under inner-wear for dysmenorrhea. Methods: We introduced far-infrared radiation functional under inner-wear to women in childbearing-age by internet portal site. Then, we preliminarily examined dysmenorrhea severity by VAS(visual analogue scale) questionnaire to women interested in far-infrared radiation functional under inner-wear. We selected women scored 5 and above of 10 measurement VAS score. Finally, 121 women were the subject of study and used far-infrared radiation functional under inner-wear for one menstrual cycle. Before and after use of far-infrared radiation functional under inner-wear, we conducted a questionnaire survey of dysmenorrhea severity by VAS. After that, we compared VAS score before and after use. Also, we studied correlation between frequency of far-infrared radiation functional under inner-wear use and ${\Delta}VAS$(VAS score before use minus VAS score after use). For statistics, we used Paired samples test and Spearman's rho correlations, SPSS 13.0 for windows. Results: Before and after use of far-infrared radiation functional under inner-wear, VAS score means were different. Frequency of far-infrared radiation functional under inner-wear use was correlated to ${\Delta}VAS$. Statistically they showed significant result (p<0.05>. Conclusion: The results showed that dysmenorrhea severity by VAS decreased after far-infrared radiation functional under inner-wear use. As frequency of use increased, ${\Delta}VAS$ increased. So we can consider far-infrared radiation functional under inner-wear effects dysmenorrhea severity.

  • PDF

원적외선 전신조사가 류마티스 관절염 유발 흰쥐에 미치는 영향 (The Effects of Far-Infrared on Rheumatoid Arthritis Induced Rats)

  • 김계엽;조경오;김명희;정현우
    • 동의생리병리학회지
    • /
    • 제18권5호
    • /
    • pp.1301-1308
    • /
    • 2004
  • The purpose of this study was to observe the effects of far-infrared on rheumatoid arthritis induced rats by type ⅡI collagen with the change of arthritis index, hind paw volume, TNF-α and histopathologic findings. Thirty-six Sprauge-Dawley rats which were divided into four group. Group Ⅰ : Normal group, Group Ⅱ : Collagen-Induced Arthritis group, Group Ⅲ : Far-Infrared 25㎝ radiation group, Group Ⅳ : Far-Infrared 35㎝ radiation group. The results of this study were as follows: In arthritis index, far-infrared radiation group(Ⅲ, Ⅳ) are more decreased than collagen-induced arthritis group(Ⅱ). Group Ⅲ and Ⅳ showed the most significant effect at 14 day(p<0.05). In hind paw, far-infrared 25㎝ radiation group(Ⅲ) significantly decreased more than only collagen-induced arthritis group on day 14(p<0.05). Far-infrared 35㎝ radiation group(Ⅳ) significantly decreased more than collagen-induced arthritis group on day 3, 7 and 14(p<0.05). In the ELISA study of TNF-α concentration, collagen-induced arthritis group significantly increased in the concentration more than normal group. Far-infrared radiation group(Ⅲ, Ⅳ) decreased in TNF-α concentration more than collagen-induced arthritis group(Ⅱ) on day 14. In histopathologic findings, collagen-induced arthritis(Ⅱ) and far-infrared 25㎝ radiation group(Ⅲ) increased in synovial membrane thickness on 3 day. Far-infrared 35 em radiation group(Ⅳ) decreased in the concentration more than collagen-induced arthritis group on day 14. The above results suggest that far-infrared radiation effectively reduced in rheumatoid arthritis. It would be considered that far-infrared has an effects on relieving rheumatoid arthritis.

원적외선 방사 세라믹의 소결공정 최적화 (Optimization of sintering process of the far-infrared radiation ceramic)

  • 박재화;김현미;강효상;최재상;최봉근;남기웅;남한우;심광보
    • 한국결정성장학회지
    • /
    • 제26권1호
    • /
    • pp.28-34
    • /
    • 2016
  • 원적외선 방사세라믹은 인체의 피부 안쪽으로 깊숙이 적외선을 침투시켜 온열 및 치료환경을 주는 매력적인 재료로써, 열적 치료 장치, 온열 매트, 히터 등과 같은 분야에 많은 응용이 되고 있다. 본 연구에서는 소결 온도와 시간을 변화시킴으로써 높은 방사율을 가지는 원적외선 방사세라믹의 소결 조건을 최적화하고자 하였다. 원적외선 방사체의 상 분석은 XRD로, 그 파단면의 미세구조는 SEM을 이용하여 분석하였다. 원적외선 방사율의 측정은 FT-IR으로 행하여, 결과를 종합적으로 해석하여 소결체의 최적 공정 조건을 확립하였다.

The Influence of Cardiovascular system caused by warming effect of Far-infrared radiation

  • Lee, Hai-Kwang;Kang, Se-Gu;Lee, Chung-Keun;Jang, Yoon-Ho;Kim, Sung-Joong;Lee, Myoung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2221-2225
    • /
    • 2003
  • As a result of using a heat generator to experiment the physiological influence of the human body due to the warming effect of far-infrared radiation (FIR), the blood pressure of the subjects lowered and stabilized due the expansion of capillary vessels and salt discharge during perspiration as the temperature of the generator elevated($30{\sim}65^{\circ}C$). In case of heart rate, it decreased and stabilized when the temperature of the ‘far-infrared radiation heat generator’ was at a low temperature below $40^{\circ}C$. At a high temperature above $44^{\circ}C$, there was a slow elevation in the heart rate. However, the elevation of the heart rate is not a sudden elevation, therefore, does not give much stress to the heart.

  • PDF

단판의 두께가 곧은결 및 무늬결 무늬목단판의 원적외선건조 특성에 미치는 영향 (Effect of Veneer Thickness on a Far-infrared Radiation Drying Characteristics of Edge-and Flat-Sliced Veneers for Decoration)

  • 이남호;최준호;황의도
    • 한국가구학회지
    • /
    • 제11권1호
    • /
    • pp.61-68
    • /
    • 2000
  • This study was carried out to investigate the effect of grain and veneer thickness on drying rate, required energy consumption, and drying defects such as checking, end waving, and burning during a far-infrared radiation drying process of decorative veneers of hard maple and beech. Most of the veneer could be dried from green to in-use moisture content within 30 to 360 seconds. The drying rates were significantly affected by veneer thickness, but there was little difference between edge-and flat-sliced veneers. The formation of checking during drying test was none or very slight. The percentages of the veneers defected by checks were higher in the flat-sliced veneers than in the edge-sliced veneers. The maximum end wavinesses in the flat-sliced veneers were almost 1.6 to 3 times larger than that in the edge-sliced veneers. All veneers were fee from burned marks during drying test.

  • PDF

무늬목 단판의 원적외석 건조 특성 (The Characteristics of Far-infrared Radiation Drying of Decorative Veneer)

  • 이남호
    • Journal of the Korean Wood Science and Technology
    • /
    • 제25권4호
    • /
    • pp.22-28
    • /
    • 1997
  • This research was carried out to obtain the fundamental data for the development of the technology and practical use of far-infrared radiation(IR) drying of quarter-sliced decorative veneers of walnut and red oak. The average drying rates of IR drying were about one and half to four times those of kiln drying and this tendency was prominent in thin veneer. The end wavinesses of the IR-dried veneers were smaller than those of kiln-dried veneers. These were largely recovered by the cold treatments after drying. The consumed electric power for IR drying was about one-fifth to two-fifthes compared to that for kiln drying.

  • PDF

$MnO_2$ 첨가량에 따른 $BaTiO_3$계의 PTC효과와 원적외선 방사특성에 관한 연구 (A study on the Radiation Properties of Far-infrared and PTC Effect in the $BaTiO_3$ system by $MnO_2$ Amounts of Additives)

  • 송민종;박춘배;강도열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 춘계학술대회 논문집
    • /
    • pp.3-5
    • /
    • 1993
  • It is very important that a spectrum of reflectance is in accord wi th a spectrum of absorbance for a effective heating. Therefore. the objective of this study was to achieve a technical composite for material plan which PTC thermistor increase a radiation property of far-infrared and keep a characteristic of R-T The Ceramic speciman studies had the composition $BaTiO_3$ with additive of 1.67 $Al_2O_3$, 3.75 $SiO_2$, 1.25 $TiO_2$, 0.15 $Sb_2O_3$ and 0.00-0.182 $MnO_2$. $MnO_2$ amounts of additives was both increase on the anomalous resistivity-temperature characteristics and high efficiency on the radiation properties bodies of far-infrared. This result shows that specimens produced high emissivity(average 0.8) of far-infrared at 4.5-15$[{\mu}m]$ by measuring a characteristic of IR and R-T.

  • PDF

반도성 PTC 서미스터의 원적외선 방사특성에 미치는 MnO의 영향 (The Influence of MnO doped on the Radiation Properties of Far-Infrared in Semiconduction PTC Thermistor.)

  • 송민종;조현섭;장성환;박춘배;김충혁;이준웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.204-208
    • /
    • 1991
  • In this paper, the radiation properties of a far-Infrared using a PTC thermistor, the $BaTiO_3$+1.63mol% $Al_2O_3$+3.75mol% $SiO_2$+1.25mol% $TiO_2$(1/3 $Al_2O_3+xSiO_2$+(1-x) $TiO_2$; total x: 6.67mol%) ceramics, in order to progress the grade resistivity characteristics, by adding an ethanol solution of $Mn(NO_3){\cdot}6H_2O$ was investigated. The ceramics was fabricated by wet-mill method. The sintering temperature read 1300-1350$[^{\circ}C]$ and the holding time was 3 hours. The quantity of $Sb_2O_3$ and $Al_2O_3$ for an activation of the far-infrared radiation in ceramics was doped. In sintering, R-T property was measured by varying the grade temperature. The anatase-lighting apparatus and microstructures by using XRD and SEM were observed. $Sb_2O_3$. oxides additive. affected the semiconducting and emissivity and MnO was devoted an increase of resistivity. The specimen which only $Sb_2O_3$ is added to was high appeared far-infrared emissivity and Mno was not affacted the far-infrared radiation. The ceramics shows that it is effective in the structure of the human bodies as organic bodies and can be applied as electron device.

  • PDF

Far Infrared Emissivity of Wood Material - Comparing the Three Heat Transfer Modes of Wood Box and Aluminum Box

  • Lee, Hwa-Hyoung;Bender, Donald A.
    • Journal of the Korean Wood Science and Technology
    • /
    • 제37권5호
    • /
    • pp.440-450
    • /
    • 2009
  • In case of wood flooring, the high emissivity would be one of the most important properties especially as the cover material of underfloor heating system. The FIR (Far Infrared) materials such as wood emit FIR energy by heating, which has been used as the medical therapy such as dry sauna. This research investigated the emissivity and the emission power of wood composites by comparing the amount of the three heat transfer modes transferred by infrared radiation which came from the increased temperature of the bottom board of the plywood box by the heater. The results showed the value of radiation mode was the highest mode for the plywood box, and the convection mode was the main mode for the aluminum box. The rate of convection was 81.8% in the aluminum box and 48.2% in the plywood box, respectively. In case of the rate of radiation, the aluminum box showed only 15.4% and the plywood box showed 51%. The emissivity and the emission power of birch plywood showed the same values as those of wood. The amount of energy required for the temperature rising of water within vial in the aluminum box and in the plywood box were 3.32 kJ and 6.70 kJ respectively, which showed that the vial temperature of the plywood box was two times higher than that of the aluminum box.