• Title/Summary/Keyword: feeder line

Search Result 182, Processing Time 0.029 seconds

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.79-82
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder. The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

Investigation of On-line Monitoring Method on 1500 V Direct Current Cable of Subway

  • Shen, Xiaojun;Jiang, Xiuchen;Yi, Zeng
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.247-251
    • /
    • 2006
  • The traction DC feeder cable is one of the key devices for the safety operation of subway system, but for low voltage DC feeder cable (<3000 V) for subway, little attention has been paid by investigators on its online monitoring technology. With an introduction of cable laying and operation environment for the cable, this paper investigated the on-line monitoring technology of 1500 V DC feeder cable of subway. Firstly, in the text, the fault model of 1500 V DC cable was proposed based on the analysis of the fault type of the DC feeder cable, and then put forward synthetically on-line monitoring discharge signal and DC leakage current signal to assess DC feeder cable insulating state. The results of laboratory experiment prove that the proposed methods are feasible and can be implemented on-line monitor on DC feeder cable of subway.

Analysis on the Stress and Economy of Feeder Supporting Metal Designed a Steel Pipe (강관을 이용한 급전선금구의 응력해석 및 경제성 분석)

  • Na, Hyun;Ahn, Young-Hoon;Lee, Ki-Won
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.5
    • /
    • pp.499-503
    • /
    • 2008
  • The catenary line and feeder line installed on same electrical pole in opened place of AC electrical rail-road. The Electrical pole has receive a different weight from the catenary line and feeder line. So we have designed the Feeder supporting metal with new shape and material based on this fact. And then we have examined the stability of Feeder supporting metal designed a steel pipe by FEM program. New steel pipe compared with existing steel pipe on a economy respect. That result give proof the stability and economy as feeder supporting steel. There-fore this device have a basic of Value Engineering, so we have the need of reflection to design as a device of new electrical pole.

Analysis on the stress and economy of Feeder supporting metal designed a steel pipe (강관을 이용한 급전선금구의 응력해석 및 경제성 분석)

  • Na, Hyun;Ahn, Young-Hoon;Lee, Ki-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.286-291
    • /
    • 2008
  • The catenary line and feeder line installed on same electrical pole in opened place of AC electrical railroad. The Electrical pole has receive a different weight from the catenary line and feeder line. So we have designed the Feeder supporting metal with new shape and material based on this fact. And then we have examined the stability of Feeder supporting metal designed a steel pipe by FEM program. New steel pipe compared with existing steel pipe on a economy respect. That result give proof the stability and economy as feeder supporting steel. Therefore this device have a basic of Value Engineering, so we have the need of reflection to design as a device of new electrical pole.

  • PDF

Development of A Feeding Device for Screw/Bolt Using the Sliding Method (슬라이드 방식을 이용한 스크류/볼트 피더기 개발)

  • Kim, Yong-Seok;Jeong, Chan-Se;Yang, Soon-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.4
    • /
    • pp.502-508
    • /
    • 2011
  • In this paper, we proposed vertical feeding mechanism for a slide parts feeder using the slide type method. This parts feeder of the slide type method have been proposed to suppress the dust generation from the feeding objects. The proposed parts feeder mechanism is composed with the casing hopper, the vertical feeding unit, the in-line feeder and linear shooter unit. And, these mechanisms did modularity through optimum design by means of mechanical and dynamical analysis using the RecurDyn(multi-body dynamics) analysis module. Also were carried out the virtual prototype using the 3-D CAD program. And it had been manufactured as the prototype of the slide parts feeder. The field test for validation of performance was performed directly at the inspection line of bolt and screw. In the field test, this slide parts feeder showed an efficiency of about 1.2 times the bowl feeder. It also showed an epoch reduction in the dust generation compared to the vibration bowl feeder. So this slide parts feeder will be applied useful in the vision inspection system for a screw and bolt.

Echelon Feeder of Brown Rice for On-line Inspection Using Image Processing (영상처리식 온라인 품위판정을 위한 현미의 정렬공급장치)

  • Kim, Tae-Min;Noh, Sang-Ha
    • Journal of Biosystems Engineering
    • /
    • v.35 no.3
    • /
    • pp.197-205
    • /
    • 2010
  • An automatic echelon feeder of brown rice was presented for quality inspection system using color image processing. A echelon feeder was developed with vibratory feeder and cylindrical indent singulator having oblique light. The vibratory feeder consisted of a hopper, electromagnetic vibrator and multichannel grooves and supply the grain sample to the singulator. The feeding performance such as feed rate, blocking frequency of the channel was dependent on the size of groove and vibration pattern. A cylindrical indent singulator consisted of a rotating cylinder, prisms and a tungsten-halogen light source. It delivered grain kernels under the camera in a echelon form and illuminate the kernels with oblique ray and ambient light. The size of the indents installed on the surface of the rotating cylinder was determined by the dimensions of the paddy and a small triangular prism was placed in each indent to apply $ 20^{\circ}$ oblique light to the grain kernel.

The study on the prevention of DC feeder line cable grounding fault (DC 급전케이블 지락사고 보호방안에 관한 연구)

  • Park, Ji-Soo;Song, Joong-Ho;Park, Joung-Wook
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.202-207
    • /
    • 2008
  • This study provides review and improvement plans for the possible problems caused when the CV cable is used as a positive feeder line which supplies power from the DC HSCB (high-speed circuit breaker) to the catenariesin Seoul Metro which is using direct-current feeder method. In detail, this study contributes to stabilizing the power line by triggering a protective device by instantly detecting potential rise which happens when grounding fault occurs in non-grounding type CV cable shield.

  • PDF

The Switch Installation Criteria For Satisfying Future Reliability Goal (향후 신뢰도 목표를 만족하는 개폐기 설치 기준 제시)

  • Jo, Nam-Hun;O, Jeong-Hwan;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.9
    • /
    • pp.433-440
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

A New Algorithm of The Line to Ground Fault Section Isolation & Restoration in Ungrounded Distribution Power System (비접지 배전 계통에서 지락사고 시 고장구간 분리 및 복구를 위한 새로운 알고리즘)

  • Choi In. S.;Choi Myeon. S.;Lim Seong. I.;Lee Seung. J.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.10
    • /
    • pp.550-555
    • /
    • 2004
  • Fault section isolation and service restoration are very important for function of DAS. In Japan, a progressive protection method is used for the line to ground fault section isolation and service restoration. But the progressive protection method has a drawback that the customer will experience outage time and that the rate in use of the feeder is not over 50%. This paper presents a new Service Restoration Algorithm which is for the line to ground fault section isolation and service restoration method for a ungrounded distribution system. If the proposed algorithm is used, the rate in use of the feeder can improve than before because a distribution system can change multi connection of feeder and the customer's outage time can be reduced. The proposed algorithm has been successfully tested in a distribution system.

A Study on the Optimum Scheme for Determination of Operation Time of Line Feeders in Automatic Combination Weighers

  • Keraita James N.;Kim Kyo-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1567-1575
    • /
    • 2006
  • In an automatic combination weigher, the line feeders distribute the product to several weighing hoppers. The ability to supply appropriate amount of product to the weighing hoppers for each combination operation is crucial for the overall performance. Determining the right duration of operating a line feeder to supply a given amount of product becomes very challenging in case of products which are irregular in volume or specific gravity such as granular secondary processed foods. In this research, several schemes were investigated to determine the best way for a line feeder to approximate the next operating time in order to supply a set amount of irregular goods to the corresponding weighing hopper. Results obtained show that a weighted least squares method (WLS) employing 10 data points is the most effective in determining the operating times of line feeders.