• Title/Summary/Keyword: fine needle

Search Result 764, Processing Time 0.027 seconds

Validity of Frozen Biopsy during Thyroidectomy (갑상전 절제술시 동결절편조직검사의 유용성에 대한 평가)

  • Kim Seong-Yeal;Kim Jung-Gu;Choi Young-Sik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.1
    • /
    • pp.81-87
    • /
    • 1998
  • Fine needle aspiration cytology was used widely to select thyroid nodules for surgery. The result could be highly reliable for most malignancies and for benign nodules. The purpose of this study was to determine the value of frozen biopsy by directly comparing the results of preoperative fine needle aspiration cytology to frozen biopsy examination. In our university hospital, 103 patients with thyroid nodule were operated during the years 1996 through 1997. A comparison of accuracy of the fine needle aspiration cytology with frozen biopsy was made for 85 patients who underwent both procedures. The 85 patients were separated into two groups. The group I included 65 patients, whose preoperative fine needle aspiration cytology results were reported as benign or malignant lesion definitely. The group II included 85 patients, the patients whose reported fine needle aspiration cytologic result was suspicious for malignancy were regarded .as malignant lesion and results for follicular neoplasm were regarded as benign lesion. The accuracy of both procedures was compared on two group also. The sensitivity, specificity, and accuracy of frozen biopsy were 76.7%, 93.5%, and 85.2% in group I and 75.6%, 95.5%, and 85.9% in group II, respectively, compared with 63.3%, 87.1%, and 75.4% in group I and 65.4%, 81.8%, and 72.9% in group II for fine needle aspiration cytology. On benign lesion, the accuracy was 95.5% in frozen biopsy and 68.2% in fine needle aspiration cytology, 75.6% in frozen biopsy and 53.7% in fine needle aspiration cytology on malignant lesion. We conclude that although fine needle aspiration cytology is the reliable diagnostic test in the evaluation of thyroid nodule, frozen biopsy should be performed intraoperatively, because fine needle aspiration cytology is insufficiently sensitive for reliable surgical planning.

  • PDF

A Case of Parotid Warthin Tumor with Granulomatous Necrosis After Fine-Needle Aspiration (이하선 Warthin 종양의 세침흡인검사 후 발생한 육아종성 괴사 1예)

  • Oh, Hyeon Sik;Lee, Eun Sub;Jo, Young Tae;Kwon, Minsu
    • Korean Journal of Head & Neck Oncology
    • /
    • v.34 no.2
    • /
    • pp.57-60
    • /
    • 2018
  • Fine needle aspiration is usually performed as a preoperative cytologic evaluation in salivary gland tumors, and complications of the lesion after fine needle aspiration are scarcely developed. The secondary change of tissue by fine needle aspiration can make the diagnostic and subsequent therapeutic difficulties for clinicians and require a careful approach. Fine needle aspiration can cause variety of changes in Warthin tumor, and it is presumed that those changes are mainly caused by the infarction of the mass due to vascular injury and following inflammatory reactions. We would introduce our experience of granulomatous and necrotic change after fine needle aspiration on parotid Warthin tumor with consequent difficulties in diagnostic and surgical approach to the patient.

Diagnostic Accordance Rate and Accuracy Between Cytological and Histological Test in Lung Disease (폐질환에 있어 세포검사와 조직검사의 진단 일치율 및 정확도에 대한 조사 연구)

  • Kim, Sung-Chul;Ro, Joung-Whan;Kim, Tai-Jeon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.4
    • /
    • pp.189-195
    • /
    • 2009
  • Lung cancer is a type of cancer with high mortality; its 5-year survival rate is at a low 14%. Related cytological tests include sputum, bronchial brushing, bronchial washing and fine needle aspiration cytology test etc. From the test specimens in which sputum, bronchial brushing, bronchial washing, and fine needle aspiration cytology were performed, the sensitivity, specificity and accuracy between cytology test and histology test. In the sputum test, sensitivity was 27.71% and specificity was 98.02%, and the bronchial brushing test showed sensitivity of 93.33% and a specificity of 91.3%. The bronchial washing test was a sensitivity of 53.7% and its specificity was 98.9%, and the fine needle aspiration cytology test showed sensitivity and specificity were 88.46% and 72.97%, respectively. In the specimens diagnosed as normal at the sputum test, malignant diagnosis was found in 21 specimens of bronchial brushing, 30 cases of bronchial washings and 37 cases of fine needle aspiration cytology specimens. In the specimens diagnosed as normal at the bronchial washing test, malignant diagnosis was found in 5 specimens of sputum, 7 specimens of bronchial brushin and 1 cases of fine needle aspiration cytology. One specimens found to be normal in fine needle aspiration cytology turned out to maligant in sputum test. The result of this research shows that, in diagnosis lung cancer, a test method of high sensitivity and specificity should be pursued. However, depending on the location and malignancy of the illness, diagnosis may not be obtained in some cases. Therefore, we conclude that the cytological tests performed for lung cancer testing such as sputum, bronchial brushing, bronchial washing, and fine needle aspiration cytology should be carried out in a mutually complementary manner.

  • PDF

Clinical Application of Ultrasound-Guided Thyroid Fine Needle Aspiration Biopsy and Thinprep Cytology Test in Diagnosis of Thyroid Disease

  • Wei, Ying;Lu, Yao;Li, Chenxi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.10
    • /
    • pp.4689-4692
    • /
    • 2016
  • Purpose: To study the clinical application value of ultrasound guided thyroid fine needle aspiration biopsy and thinprep cytology testing in diagnosis of thyroid disease. Methods: A total of 78 patients with thyroid nodules were enrolled, 34 males and 44 females, aged 33-64 years old with mean age of 47.6 years. All underwent thyroid module fine needle puncture after surgery to assess cell pathology and histopathological features. Results: Sufficient specimens were obtained from all of 78 patients, the cytological results of 73 cases (93.6 %) being consistent with pathological results. While 20 cases (25.6 %) were malignant tumors, 44 (56.4 %) were benign and 9 (11.5 %) were non-tumor lesions. The sensitivity of benign and malignant thyroid nodule by thyroid fine needle puncture was 90.9 %, specificity was 98.1 % and the positive predictive value was 96.3 %. Conclusions: It is demonstrated that ultrasound-guided thyroid fine needle aspiration biopsy and thinprep cytology testing have diagnostic value in clinical application for thyroid disease,showing good diagnostic coincidence rates with histopathological examination. They can thus be regarded as safe and effective for preoperative diagnosis and providing an appropriate basis for selection of surgery.

A Cytologic Study of Fine Needle Aspiration Biopsy of Salivary Gland Diseases (타액선 질환의 세침흡인생검에 관한 세포학적 연구)

  • Kim, Mi-Jin;Lee, Tae-Suk
    • The Korean Journal of Cytopathology
    • /
    • v.5 no.2
    • /
    • pp.120-129
    • /
    • 1994
  • Fine needle aspiration biopsy cytology is a widely recognized and useful technique which can provide diagnosis in lesions of the head and neck, enabling appropriate management plans for individual patient to be made. Fifty one fine needle aspirates from salivary gland masses were examined. Four aspirates (8%) were inadequate for examination. Of the remaning 47 samples, 42 cases (82%) were benign lesions which consist of 30 pleomorphic adenoma(58%), 7 inflammatory lesion (14%), 4 Warthin's tumor(8%) and 1 benign lesion(2%). Two cases(4%) were atypical lesions. Three cases(6%) were malignant lesions consisting of 2 adenoid cystic carcinomas(4%) and 1 mucoepidermoid carcinoma (2%). The cytologic diagnoses were compared with the subsequent histologic diagnosis of surgical resected specimen in 24 cases. 19 cases of 21 aspirates from benign tumors were correctly diagnosed by fine needle aspiration cytology, with a specificity of 90%. All 3 aspirates from the 3 patients with malignant tumor were correctly diagnosed by fine needle aspiration cytology, with a sensitivity at 100%. Overall acurracy was 88%. Diagnostic error was encountered in adenoid cystic carcinoma, mucoepidermoid carcinoma and Warthin's tumor Correct histologic diagnosis was made in 86% of benign tumors(84% for pleomorphic adenoma and 100% for Warthin's tumor) and in 100% of malignant tumors.

  • PDF

Fine Needle Aspiration Cytologic Findings of Thyroid Lymphoma -Report of Two Cases- (갑상선 림프종의 세침흡인 세포학적 소견 -2 예 보고-)

  • Lee, Hye-Kyung;Lee, Jong-Min;Kang, Chang-Suk
    • The Korean Journal of Cytopathology
    • /
    • v.13 no.1
    • /
    • pp.33-37
    • /
    • 2002
  • We report two different types of thyroid lymphoma associated with Hashimoto's thyroiditis. Both showed autoantibodies and were compatible with Hashimoto's thyroiditis according to their clinical backgrounds. A 76-year-old female noted a painless, rapidly growing mass in her neck which was diagnosed as diffuse non-Hodgkin's lymphoma, large cell type, after the fine needle aspiration cytology of the thyroid. She underwent chemo-radiotherapy and is free of the disease 10 months after diagnosis. The other patient, a 73-year-old female with a diffuse golfer, was diagnosed on fine needle aspiration cytology as having Hashimoto's thyroiditis. Three years later she developed a hard nodular growth in the both lobes of the thyroid. This was subjected to fine needle aspiration cytology and needle biopsy and was diagnosed as a MALT lymphoma. She refused any treatment and died 12 months after the diagnosis.

Fine Needle Aspiration Cytology of Metastatic Seminoma in Cervical Lymph Node - A Case Report - (경부 림프절에 전이한 정상피종의 세침흡인 세포학적 소견 - 1예 보고 -)

  • Jang, Kee-Taek;Park, Hye-Rim;Ahn, Jin-Seok
    • The Korean Journal of Cytopathology
    • /
    • v.12 no.1
    • /
    • pp.57-60
    • /
    • 2001
  • Fine needle aspiration cytology of the cervical lymph node was performed in a 63-year-old man who had had an orchiectomy for seminoma one year ago. The tumor cells were arranged in loose clusters, occasional sheets, or single cells. The nuclei were round to ovoid with fine or reticular chromatin, and had one or more prominent nucleoli. These cells were intermingled with lymphocytes in a characteristic foamy, lacelike background. Documented reports of the cytologic appearance of the seminoma are rare, especially in the metastatic lesion. The diagnosis of primary gonadal seminoma by fine needle aspiration cytology is probably not indicated since the treatment of primary gonadal tumor requires surgical resection. Because of the characteristic cytologic features, fine needle aspiration cytology may be helpful in evaluation of the extent of tumor spread in the patients with testicular tumors.

  • PDF

Fine Needle Aspiration Cytology of Chondroblastoma Arising in the Rib - Report of A Case - (늑골에 발생한 연골아세포종의 세침흡인 세포학적 소견 - 1예 보고 -)

  • Kwon, Kye-Hyun;Jin, So-Young;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.5 no.1
    • /
    • pp.61-64
    • /
    • 1994
  • Chondroblastoma is a benign bone tumor accounting for less than 1 % of bone tumor. It infrequently involves the flat bones, among which ribs are particularly rare. On fine needle aspiration cytology, the diagnostic smear consists of chondroblasts, osteoclast-like giant cells, and chondroid matrix. The cytologic hallmark to differentiate from other giant cell-containing lesions is chondroblasts. We experienced a case of chondroblastoma in a 13-year-old female. Fine needle aspiration cytology from the 5 th rib revealed dispersed chondroblasts and osteoclast-like giant cells on hemorrhagic background. Chondroblasts had round to oval nuclei with fine, evenly distributed chromatin and distinctive grooves or indentation. Their cytoplasm was well-defined.

  • PDF

Analysis of Fine Needle Aspiration Results of Thyroid Nodules in Ultrasonography (초음파검사에서 갑상샘 결절의 세침흡인세포검사 결과에 따른 분석)

  • Kwak, Jong-Gil;Han, Jae-Bok;Song, Jong-Nam;Moon, Il-Bong;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.5
    • /
    • pp.290-297
    • /
    • 2016
  • This study analyzed the features of the nodules requiring a fine needle aspiration, which were found in thyroid ultrasonography of the employee health check-up examinees. Based on the fine needle aspiration results, over 1 cm nodules or those implying malignancy on the ultrasonography were categorized into the 1st group. Whereas, regardless of the size the fine needle aspiration results implying malignancy on the ultrasonography were categorized into the 2nd group. In the 1st group, 15.8% were malignant, and in the 2nd group, 28% were malignant. The findings implying malignancy were statistically significant. However, even though the nodules were larger than 1 cm, when the nodules were not accompanied by a high risk factor and showed a spongiform structure in the ultrasonographic results, most of them were benign, and a fine needle aspiration was not required. The ultrasonographic findings are important rationales in making a decision on whether or not a fine needle aspiration is required for thyroid nodules. Currently, the fine needle aspiration for thyroid nodules is commonly performed when the size of the nodule is larger than 1 cm, even though it has a spongiform structure, to relieve the patient's anxiety. However, if ultrasonographic findings of thyroid are correctly understood in differentiating malignant from benign nodules, unnecessary fine needle aspiration can be avoided.

Fine needle aspiration biopsy for the diagnosis of fatty liver in cattle (Fine needle aspiration biopsy에 의한 소의 지방간진단(脂肪肝診斷))

  • Hwang, Bum-tae;Han, Hong-ryul
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.1
    • /
    • pp.109-121
    • /
    • 1991
  • This study was carried out to investigate the morbidity of fatty liver in cattle at the abattoir and on the farm, and to cytodiagnose fatty liver in cattle by fine needle aspiration biopsy. Incidence rates of fatty liver in cattle, detected macroscopically or based on hepatic lipid content by buoyancy, were 0.30% in Korean native cows, 4.70% in dairy cows, and 0.15% in dairy bull. Fatty liver was enlarged, swollen with round edges, light weight, and pale to yellow-orange color, but its color was not always correlated to the severity of fatty liver. The findings of fat infiltration of the hepatic lobule were large droplets around central vein, fine droplets in the periphery, and fat infiltration in the perivascular region execpt for most of normal liver and severe fatty liver. The sensitivty, specificity, and accuracy of cytological finding compared with hepatic lipid content by buoyancy were 94.4%, 95.2%, and 94.9% in normal cases, 64.3%, 100%, and 87.2% in mild cases, 100%, 83.3%, and 87.2% in moderate cases, and 100%, 100%, and 100% in sesvere cases, respectively. Cytological findings were well correlated with histological findings. Complications of fine needle aspiration biopsy were not recognized clinically. Consequently, the cytodiagnosis by fine needle aspiration biopsy is simple, rapid, safe, and economical method compared with histological techniques in the diagnosis of fatty liver in cattle.

  • PDF