• Title/Summary/Keyword: fire accident

Search Result 696, Processing Time 0.027 seconds

Derivation of Cause Variables necessary for Electrostatic Fire/Explosion Risk Assessment and Accident Investigation (정전기 화재·폭발 위험성평가 및 사고조사에 필요한 발생원인 변수 도출)

  • Junghwan Byeon;Hyeongon Park
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.9-21
    • /
    • 2024
  • Static-electricity-induced fires and explosions persistently occur every year, averaging approximately 80 and 20 cases annually according to fire statistics provided by the National Fire Agency and industrial accident statistics provided by the Ministry of Employment and Labor, respectively. Despite the relatively low probabilities of these accidents, their potential risks are high. Consequently, effective risk assessment methodologies and accident investigation strategies are essential for efficiently managing static-electricity hazards in fire- and explosion-prone areas. Accordingly, this study aimed to identify the causal variables essential for accident investigations, thereby facilitating risk assessments and the implementation of effective recurrence prevention measures to mitigate static-electricity hazards in fire-and explosion-prone regions. To this end, industrial accident statistics recorded over the past decade (2012 to 2021) by the Ministry of Employment and Labor were analyzed to identify major fire and explosion incidents and related industrial accidents wherein static electricity was identified as a potential ignition source. Subsequently, relevant investigation reports (63 cases) were thoroughly analyzed. Based on the results of this analysis, existing electrostatic fire and explosion risk assessment techniques were refined and augmented. Moreover, factors essential for investigating electrostatic fire and explosion disasters were delineated, and the primary causal variables necessary for effective risk assessments and scientific investigations were derived.

A Study on Developing the Educational Program for the Emergency Response with a Railroad Fire Accident (철도화재사고 비상대응 교육프로그램 개발에 관한 연구)

  • Roh, Sam-Kew;Park, Sang-Gyu;Ham, Eun-Gu;Kim, Si-Gon
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1511-1517
    • /
    • 2008
  • In January, 2005, "railroad security law" was presented, preparing the systematic equipment that allows several railroad operators to consider the railroad security issue, and each of railroad operative institutions accepted such situation that construct the integral railroad security system, resulting in constructing the emergent system coping with the railroad fire accident through the relevant study business to improve the railroad security efficiency against fire. This study tried to present the studying direction on developing the emergent educational program coping with the railroad fire accident, which is distributed to the spot, about the railroad worker for improving the railroad security efficiency against fire through the education of systematic and efficient emergent countermeasure procedure of emergent system against the railroad fire accident.

  • PDF

Discussions on the Cause of Bucheon LPG Station Accident (부천 LPG 충전소 사고 원인에 대한 연구)

  • 윤재건
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.31-34
    • /
    • 2001
  • Cause of Bucheon LPG refueling station accident could not be clearly verified because of opposite talking of men reponsible for the accident the accident, damaged by BLEVE and fire, and no systematic fire investigation. After two and half years, recently first judgement has been carried out. But competitive arguement is going on and first leak point of massive LPG will not be clearly identified with evidences acquired by now. This accident gave us many instructions and advices. Specially, massive LPG leak can result in pool fire and safety of underground-installed storage tank is proved by no damage in the strong BLEVE.

  • PDF

EVALUATION OF AN ACCIDENT MANAGEMENT STRATEGY OF EMERGENCY WATER INJECTION USING FIRE ENGINES IN A TYPICAL PRESSURIZED WATER REACTOR

  • PARK, SOO-YONG;AHN, KWANG-IL
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.719-728
    • /
    • 2015
  • Following the Fukushima accident, a special safety inspection was conducted in Korea. The inspection results show that Korean nuclear power plants have no imminent risk for expected maximum potential earthquake or coastal flooding. However long- and short-term safety improvements do need to be implemented. One of the measures to increase the mitigation capability during a prolonged station blackout (SBO) accident is installing injection flow paths to provide emergency cooling water of external sources using fire engines to the steam generators or reactor cooling systems. This paper illustrates an evaluation of the effectiveness of external cooling water injection strategies using fire trucks during a potential extended SBO accident in a 1,000 MWe pressurized water reactor. With regard to the effectiveness of external cooling water injection strategies using fire engines, the strategies are judged to be very feasible for a long-term SBO, but are not likely to be effective for a short-term SBO.

A Study on Developing the Educational Program for the Emergency Response against Fire Accidents in KTX (고속철도 화재사고 비상대응 교육프로그램 개발에 관한 연구)

  • Kim, Si-Gon;Park, Min-Kyu
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.41-49
    • /
    • 2009
  • In January, 2005, the "Railroad Safety Act" was presented, preparing the systematic equipment that allows several railroad operators to consider the railroad safety issue, and each of the railroad operative institutions accepted such situation that the construction of the emergent system of coping, resulting in the construction of the emergent system of coping with the railroad fire accident through the relevant study to improve the railroad security efficiency against fire. This study tried to present the on developing the emergent educational program for coping with the KTX fire accident, which is distributed to the spot, to the railroad emergency staff for improving the railroad security efficiency against fire through the education of systematic and efficient emergent countermeasure procedures against fire accidents the fire accident in KTX.

Gas Fire Accident Cause Survey Study (가스화재사고 원인조사 연구(LP가스를 중심으로))

  • Kim, Young-Cheol;Cha, Jong-Ho
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The purpose of this paper is to report gas fire accident based on classification of the major gas fire causes (including handling mistakes, inferior goods, etc.), fire classifications (fire, explosion, leakages, etc.), damage levels(1st, 2nd, 3rd, 4th grade levels), casualties (death, serious wound, slight injury) since gas fire has been generated according to growth of gaseous fuel consumption on home and enterprises with various accident causes. Among gaseous fuels, LPG facility can be c1assified as gas container, pressure regulator, gas hose, interim valve, combustion port. Any fire or any explosion can be caused from handling mistakes, inferior goods on each parts as stated above. Exact gas fire causes shall be identified based on previous case studies on similar fires with consideration of lesson learns.

  • PDF

Fire Safety Education Programs for Preventing Fire Accident of Young Children (유아 화재사고 예방을 위한 화재안전 교육프로그램 개발 방향 탐색)

  • Yoon, Sun-Hwa
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.112-122
    • /
    • 2012
  • The purpose of this study is to explore appropriate fire safety education programs for young children by both examining the actual damage condition and problems associated with fire accident in young children and considering fire safety education programs in America and legal basis for fire safety education in Korea. The results are as follows. First, the mortality of young children by fire accident in Korea is higher than that of U.K, Germany, and Sweden. Second, it is defined by the Child Welfare Law in Korea to implement the mandatory fire safety education for young children in kindergarten and preschool programs. Third, in order to activate fire safety education programs for young children, the fire safety education needs to be suitable for children's developmental characteristics, and various audiovisual materials and activity programs should be developed and provided. Fourth, fire safety education both for early childhood teachers and parents needs to be interrelated and systemized to reduce the risk of fire accident.

The Special Plan of the Traffic Accident Treatment in the Emergency Car Concerning Fire Fighting (소방관련 긴급자동차의 교통사고처리 특례방안)

  • Jeng, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.20-29
    • /
    • 2008
  • The traffic accident of Fire engine takes place very much, compared with that of the past. The reason is that there is a lot of the increase of the demand in the fire, rescue, first aid, and the public request. Also, because the Fire engine should go out at the place of the accident very quickly, it should inevitably violate the traffic regulations. Therefore, this is due to the traffic accident. Despite the urgent situation in the infringement motive of traffic regulations, the outbreak of the traffic accident does not vary largely from the degree of the disadvantage. Accordingly, a fire officer should take charge of his social and economic disadvantage by himself. In this situation, a fire officer has no choice but to start moving passively not to be afflicted with his own disadvantage. Most of the situations concerning the fire fighting are the ones to be controlled urgently. Nevertheless, because of the disadvantage of the traffic accident, passive mobilization of the fire fighting equipment is the heavy burden of all the people of the nation. Therefore, Special institutional safety device should be ready for the protection of the life and property of all people. The special law concerning the processing in the accident of the emergency car needs to be revised. By establishing this special law, the government should not provide the officer who drives the fire engine with the disadvantage caused by traffic accident.

A Study on the Emergency Response System by Five Sense in the Subway Fire (오감인지를 통한 지하철 화재 비상대응시스템에 관한 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.76-83
    • /
    • 2008
  • In the subway fire case, it is important that judge accuracy subway fire type and on the initial response minimize accident damage. But when the subway fire accident occurring, if it have know impossible that accuracy subway fire type to judge at once though witnessing driver or emergency response staff. This study suggests type of five senses that using information of five sense take to the subway fire accident information which analyses five senses as occurring subway fire accident. Also it is proposed that emergency response system though fire scenario by using Activity-Action Diagram(AAD).

The Effects of Parameters Affecting the Results in the Jet Fire for the Vapor Release Accident (증기누출사고의 영향평가에서 제트화재에 미치는 매개변수의 영향)

  • 조지훈;하정호;함병호;윤대건;김태옥
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.53-56
    • /
    • 1996
  • In order to propose the method of the consequence analysis for fire accidents by the heavy gas release and to obtain optimum conditions of parameter selections, the consequence analysis for jet fire by the accident of xylene vapor release were performed. And the effect and the sensitivity analysis of parameters affecting the consequence were investigated. Simulation results showed that important parameters affecting results of the xylene vapor release accident were mainly hole diameter, interested distance, wind speed, and so on. For the jet fire, the accident result and the sensitivity of thermal radiation were increased with the decrease of interested distance and the increase of hole diameters, and the accidental result was increased as the increase wind speed, but the sensitivity of thermal radiation was decreased.