• Title/Summary/Keyword: fire plume ejected from an opening

Search Result 5, Processing Time 0.025 seconds

A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea (국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구)

  • Lee, Kyu-Min;Koo, Tae-Yoon;Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF

Experimental Study on Flame Trajectory in Building External Walls Fire (건축물 외벽화재시 Flame Trajectory 추정을 위한 실험적 연구)

  • Shin, Yi-Chul;Park, Kye-won;Jeong, Jae-Gun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.79-80
    • /
    • 2016
  • In the event of a fire on the outer walls of an architectural structure, through real scale experiments with the purpose of estimating the Flame Trajectory, the behavior and risks of expanded combustion to an upper architectural compartment of the Fire Plume Ejected from an Opening according to changes in the aspect ratio of the opening were examined. The results showed that the more the heat release rate of the fire source increased, the heat capacity of the Fire Plume Ejected from the Opening also increased, and for the case of heptane when compared with methanol or ethanol, the results showed a trend for a significant amount of unburned gas to remain. The results also showed that the larger the aspect ratio was, the more likely it was for the Flame Trajectory to approach the outer walls and rise up. In each of the experiment conditions, as the flame rose from the lower part of the wall to the upper part of the wall, a steady decrease was shown for the temperature distribution. Also by quantitatively analyzing the amount of unburned gas that remained, a method to estimate the temperature of the Fire Plume Ejected from an Opening for a traverse opening was implemented.

  • PDF

Study on the Ejected Plume from Opening Regarding Side-wall Effect in Fire (측벽효과를 고려한 개구부 분출화염 거동 연구)

  • Jeong, Jae-Gun;Shin, Yi-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.219-220
    • /
    • 2016
  • The behavior of fire plumes has not yet been clearly identified for cases where sidewalls are installed near an opening in an unconfined space. In this research, we aim to quantitatively identify the effects on fire spread when sidewalls are located on both sides of an opening. Specifically, we focus on the effects on the fire plume of the relation between the location of sidewalls and the opening, and carry out a scale-model experiment to devise a flame height model and to evaluate the temperature distribution along the central axis of the flame.

  • PDF

Characterization of Fire Plume Ejected from an Opening (축소모형을 이용한 개구부 분출화염성상 연구)

  • Nam, Dong-Gun;So, Soo-Hyun;Lim, Woo-Sub;Lee, Jang-Won;Kim, Nam-Hyuk;Shin, Yi-Shul;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.319-323
    • /
    • 2010
  • 건축물의 창문 등에서 분출하는 화염 특성은 건축물의 화재안전성을 확보하는데 중요한 과제이다. 본 연구에서는 분출화염의 특성을 파악하여 건축물의 화재안전설계에 활용하기 위해 축소모형을 이용하여 화재실험을 실행하였다. 실험에서는 소규모 모형을 제작하고 가스버너를 화원으로 하여 개구부와 화원의 크기에 따른 분출열기류의 온도분포성상을 파악하였다.

  • PDF

A Experimental and Analytical Study on the Fire Plume Ejected from an Opening (개구분출열기류성상 예측을 위한 실험 및 해석적 연구)

  • Kim, Bong-Chan;Shin, Yi-Chul;Koo, In-Hyuk;Youn, Yoo-Hyuk;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.327-332
    • /
    • 2009
  • 2005년 발코니 확장이 합법화 된 이후로 공동주택인 아파트의 지속적인 증가와 재개발및 재건축이 이루어짐에 따라 상층부의 화재확대를 차단하는 발코니를 확장하는 세대가 증가하고 있으며, 기존의 아파트 또한 불법 발코니 확장을 하는 사례가 늘어나고 있다. 따라서 본 연구는 발코니의 화재 안전에 대한 역할의 중요성을 부각시키고자, 발코니유 무에 따른 상층부의 개구분출열기류확산실험을 모형실험을 통해서 실시 한 후 'NIST'에서 개발 된 FDS(Fire Dynamics Simulator)를 사용해 해석하였다. 실험과 FDS해석, 그리고 Trajectory를 비교하여, 종횡비에 따른 1:1인 창과 횡장창과 종장창에 대해 서로 다른 분출열기류를 보이는 것을 확인하였다.

  • PDF