• Title/Summary/Keyword: fire prevention measures

Search Result 179, Processing Time 0.03 seconds

Classification of Fire Causes in Warehouses Using the TRIZ Technique and Analysis of Preventive Measures Accordingto 4M (TRIZ기법에 의한 물류창고의 화재원인 및 4M에 따른 예방대책 분석)

  • Han, Sang-Hun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.401-412
    • /
    • 2020
  • This study analyzed the causes of warehouse fires using a creative problem-solving technique called TRIZ. It identified preventive measures by applying 4M. The results are as follows. First, this study examined the inconsistency among the causes of warehouse fires using TRIZ. Second, it analyzed human factors and fire prevention measures in warehouses such as safety standards for managers, and methods for the promotion of safety consciousness among workers, and for the reinforcement of construction technology for sandwich panel workers. Third, it identified the mechanical and facility factors and fire prevention measures in warehouses such as safety facilities, the expanded installation of safety devices, the adoption and development of fire suppression equipment, and the deployment of methods to improve the fire resistance of sandwich panels. Fourth, it presented working and environmental factors and fire prevention measures in warehouses such as the tightening of safety precautions and the supervision of working methods, and setting fire partitions both in loading places and based on performance-based design. Finally, it proposed managerial factors and fire prevention measures in warehouses such as specific targeting for firefighting with low fire hazards, reviewing the material quality regulations of non-combustible or higher for sandwich panels in the specific target of firefighting that cannot apply fire safety standards, installing sprinklers in cold storage, and mandating the installation of automated facilities with retroactive application regardless of the floor area in the warehouse with a sandwich panel structure.

A Study on Fire and Disaster prevention for Wooden Architecture Heritage: Focusing on the Wooden Catholic Secondary Station in Dangjin (목조건축유산 화재와 방재에 관한 연구: 당진지역 목조 공소건축을 중심으로)

  • Lee, Sanghee
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.4
    • /
    • pp.15-21
    • /
    • 2021
  • This study aims to derive the problems of firefighting and safety measures for architectural heritage with a wooden structure in rural areas and present their improvement measures. To identify those problems, this study grasped the features of the cultural heritage through the building structure and environment of a wooden Catholic secondary station in Dangjin, and analyzed fires that may occur and safety factors. As a result, although the mission station is an important cultural property in terms of its history, place and local identity, it had problems with disaster prevention systems such as vulnerable safety including fire and difficulties in fire recognition and initial firefighting. Therefore, this study concluded through its review and analysis that a disaster prevention system such as stronger firefighting is needed; that fire fighting facilities suitable for the characteristics of the secondary station with a wooden structure should be installed and a main player should be arranged in fire prevention activities to improve the fire prevention system of the cultural property; and that as most mission stations are located in rural areas, it is necessary to more thoroughly protect wooden-structure secondary stations from natural disasters such as forest fire and to improve fire response measures.

A Study on the Establishment of an Integrated Management System for Forest Fire Prevention and Suppression Measures (산불예방 및 진압대책의 통합관리체계 구축 방안 연구)

  • Lee, Jeong-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.163-169
    • /
    • 2022
  • Recently, in Korea, if a very large forest fire occurs due to the people's carelessness, it is of great interest because it spreads into a large forest fire. If a wildfire spreads and becomes large, it will inflict great damage (appointment and property), and the damage is irreversible. The best way to extinguish a wildfire is to prevent it before it occurs. If a forest fire occurs due to a failure in prevention, the early firefighting activities to prevent the progress of the forest fire by promptly dispatching it by reporting it and approaching the site as soon as possible should now be managed with a systematic integrated management system. To do so, it is necessary to prepare a preventive system, such as issuing warnings for each weather condition by the Korea Forest Service, consisting of cooperation (support) activities for forest fire prevention by related organizations, etc. In order to minimize the loss of precious lives and forests, measures have been taken to establish a system, to establish a prompt and accurate situation reporting system, and to establish an integrated command system (ICS) for on-site commanders.

A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit (지하공동구 화재예방활동 및 진압대책에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.63-68
    • /
    • 2010
  • Utility-Pipe Conduit is, Housing and city effectively accommodate what they absolutely need power, communications, gas, pipeline, water supply, drainage, energy facilities etc, according to expansion of urban infrastructure are derived, several ways to solve problems in, collection facilities in place are maintained and managed facility. If Utility-Pipe Conduit is damaged, as well as national security, because their impact on society as a whole, by introducing large vulnerability in the fire prevention activities and suppression measures and disaster for our situation by introducing measures, comprehensive analysis of the fire risk, it shall establish fire prevention activities and suppression through analysis of Utility-Pipe Conduit design, institutional issues, the problem of fire protection facilities, fire spread phenomenon etc. Because of Utility-Pipe Conduit is an enclosed place, so incomplete combustion due to lack of oxygen supply that there are problem such dark smoke, carbon monoxide etc, toxic combustion products and heat generation and visual impairment is an issue difficult to enter. As well as fire prevention activities, the fire In light of the particularity of the under ground than above ground fire, so this phenomenon is weak fire fighting that fire to become effective fire fighting tactics, basically it is necessary difficulty softening, non-burn softening and prevent combustion expansion of the cable is installed on the Utility-Pipe Conduit, having to considering the specificity of the response command system and relevant organizations to establish an on-site, Structural identification and other information gathering required to record of Response agencies, keep air conditioning system 24 hours and strengthening Virtual Total Training of Response agen

A Measure on the Use of Metal Fire Extinguisher for Effective Early Extinguishment of Magnesium Fire (마그네슘 화재의 효과적인 초기소화를 위한 금속화재용 소화기 활용방안에 관한 연구)

  • Nam, Ki-Hun;Lee, Jun-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.795-800
    • /
    • 2021
  • Magnesium fires require early fire extinguishment due to impulsive and rapid-fire expansion that makes difficult fire fighting. For this reason, efficient early fire fighting and appropriate prevention of fire spread are considered mainly as significant fire extinction measures. However, there is a limit to developing tools for metal fire fighting, such as devices, facilities, and fire extinguishing agents, due to a lack of regulatory instruments in South Korea. It often generates challenges to early fire fighting implementation by fire responders. Thus, the aim of this study is to investigate a measure for securing the efficiency of early fire fighting in magnesium. This study identified the applicability of the metal fire extinguisher used in the United States for magnesium fire through a performance test of a fire extinguishing agent for metal fire. Moreover, we implemented a free burning experiment using magnesium powder to compare varying combustion and extinction process that could occur during applying metal fire extinguishers. Finally, this study suggests measures of the use and application of metal fire extinguishers for magnesium.

A Study on The Fire Safety Design of Nuclear Power Plants in Korea. (원자력 발전소의 화재 안전계획에 관한 연구)

  • 김운형
    • Fire Science and Engineering
    • /
    • v.5 no.3
    • /
    • pp.15-22
    • /
    • 1991
  • It has been generally accepted that nuclear power (NPP) is suiable for power supply in korea because of its economical profits and pollution-free energy. When designing or operating a NPP. The main points to be home in mind are the hazards of and protection against an uncontrolled release of the large quantities of radioactiv substances which are always generated in a nuclear reactor while it is in iperation. Multiple independent safety systems are provided which should prevent this from occurring. Thus fire prevention measures in NPP follow the “Defense-in-depth” concept. This study aims to suggest the fire prevention measures and to demonstrate information which is needed for NPP planning and its safety assessment. The findings of this study can be used as useful data for fire protection plannings at the first phase of NPP design.

  • PDF

A Preliminary Study on Vitalization Measures for Volunteer Fire Department Organizations (의용소방대 조직 활성화 방안에 관한 시론적 연구)

  • Woo, Seong-Cheon
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.54-63
    • /
    • 2015
  • Volunteer fire department is a private firefighting organization which is set up in Seoul, metropolitan cities, city/eup/myeon to assist firefighting service. It actively participates in prevention and aid of various disasters as well as in fire prevention/extinguishment to protect people's lives and property and to promote regional development. In short, it is a nonpaid, voluntary, private service organization; it is composed of residents in the area who have spirit of service and sacrifice, wish to join, and work in their own occupation while assisting firefighting work. Yet, voluntary fire department of such nobility and sincerity has not been vitalized, and accordingly, studies regarding this issue have been conducted in firefighting organizations and academia. Therefore, purposes of this research are 1) to analyze issues of current situation through looking at basic training for new volunteer firefighter, unification of power to appoint and dismiss captain and crews of the volunteer fire department, volunteer fire firefighters with a few good people, and vitalization of female volunteer firefighters; and 2) to propose vitalization measures based on the findings above.

The fire Prevention measures of the underground transmission line (지중송전케이블의 방화대책)

  • Kwak, Bang-Myung;Tack, Eui-Gyun;Kim, Jae-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.501-503
    • /
    • 2001
  • Electric power consumption is highly increasing as the social trend requiring comfortable life, the population in a big city and the industrial development. Therefore it has become to be very important to supply the stable high-quality power. As these trend, the underground power transmission facility is highly increasing in the center of a city. As the proportion to increase facility in tunnel, the fire prevention measures of the underground transmission line become very important.

  • PDF

A study Fire Protection and Evacuation System for Buildings (건축물의 방화 및 피난계획에 관한 연구)

  • 이경수;임만택
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.9-16
    • /
    • 1988
  • This study is intended to suggest some ideal measures available in the course of construction from the viewpoint of an architect to reduce damage of human lives and Properties caused by fire accidents in buildings. For this study, 7 buildings burnt by conflaguration in Seoul during the years of 1985 and 1987 are picked up, and 105 withnesses, who were present in one of them at them at fire, are traced for personal interview and respones to the written questionaire about 5 main issues; their perceptional behaviour, their emotional state at that time, their reactions to avoid danger, their escape routes, and their usual awareness to prevent fire. Some desirable measures suggested here are ;making Provisions to install fire centers in large buildings and underground structures in the fire fighting law, and requlating to compose fire units appropriate to the quantity of combustibles inside, limit the length of a blind corridor, furnish balustrade, and limit the width of the landing of the stairs in building code and regulations. Such measures should be considered from the time of planning to construct a building, and some drill and education in fire prevention is demanded for the occupants of the buildings too.

  • PDF