• Title/Summary/Keyword: firing cycle

Search Result 57, Processing Time 0.025 seconds

A STUDY ON THE DISTORTION OF ETCHED BRIDGE DURING THE FIRING CYCLE (도재소성주기에 따른 식각가공의치의 변형에 관한 연구)

  • Park, Hui-Un;Yang, Jae-Ho;Lee, Sun-Hyung;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.73-83
    • /
    • 1986
  • The purpose of this study was to evaluate the distortion of 6-unit etched bridge during the firing cycle. Thirty frameworks were constructed. Twenty of the frameworks received a normal application of porcelain and firing sequence ; ten served as controls and subjected to the same firing sequence without the porcelain application. The results were as follows ; 1. Distortion did occur in the body of curved, long-span etched bridge frameworks during the porcelain firing cycle. 2. This distortion was a result of changes in the metal as well as the contraction of fired porcelain. 3. The greatest distortional changes occurred during the degassing stage and final glaze stage of the porcelain firing cycle. 4. Distortion incurred by the application and firing of the porcelain was reversible. When the porcelain was chemically removed from the frameworks, there was an elastic rebound. 5. Distortion was clinically important.

  • PDF

A STUDY ON THE DISTORTION OF THE COPINGS FOR CERAMOMETAL CROWNS DURING REPEATED FIRING (도재전장금관을 위한 코핑의 변형에 관한 연구)

  • Lee, Ki-Hong;Chung, Hun-Young;Lee, Sun-Hyung;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.706-718
    • /
    • 1997
  • Ceramometal crowns are common restorations in fixed prosthodontics because of their casting accuracy, the high strength properties of the metal, and the cosmetic appearance of porcelain. However, deterioration of the initial fit of the metal coping has been observed after the porcelain firing cycle. The distortion due to repeated firing makes it difficult to fit crown margin and elicits microleakage. The major causes of distortion are the residual stress that accumulate during wax-up, casting, cold work and the induced stress caused by the mismatch of porcelain-metal thermal contraction. This study examined the marginal fit changes of metal copings in relation to repeated firing and the effects of heat treatment that reduce the distortion resulted from residual stress. The marginal changes of the copings that were treated with conventional method and those treated with heat before repeated firing, were evaluated. The metal die which represented preparations of a maxillary central incisor was fabricated, and 45 wax patterns were cast with nonprecious metal alloys. The heat treatment of each group was performed as follows. Group 1(control) : Casting - Devesting - Cold work - Firing Group 2 : Casting - Heat treatment - Devesting - Cold work - Firing Group 3 : Casting - Devesting - Cold work - Reinvesting - Heat treatment - Devesting - Firing The copings were fired 3 times. After each firing, the marginal fit changes were measured with inverted metallurgical microscope at the 4 reference points located at labial, lingual, and both proximal surface. Measurements were compared, and statistically analyzed. The results were as follows ; 1. In all groups, the highest value of marginal fit changes of the copings studied were found after the first firing cycle. 2. When the distortion of each experimental group at the first firing cycle were compared, group 1 exhibited the greatest changes($20-27{\mu}m$), followed by group 2($9-13{\mu}m$), and group 3($8-10{\mu}m$). 3. The copings treated with heat before devesting(group 2) revealed significantly smaller marginal fit changes than the copings treated with conventional method(group 1). (p<0.01) 4. The copings treated with heat after reinvesting(group 3) revealed significantly smaller marginal fit changes than the copings treated with conventional method(group 1). (p<0.01) 5. No siginificant differences in marginal fit changes were found between the copings treated with heat before devesting(group 2) and the copings treated with heat after reinvesting(group 3). (p>0.01)

  • PDF

Reliability Prediction of Liquid Rocket Engines for Different Propellant and Engine Cycles (추진제 및 연소 사이클을 고려한 액체로켓 엔진의 신뢰도 예측)

  • Kim, Kyungmee O.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.2
    • /
    • pp.181-188
    • /
    • 2016
  • It is known that reliability of liquid rocket engines depends on the design thrust, propellant, engine cycle, and hot firing test time. Previously, a method was developed for estimating reliability of a new engine by adjusting the design thrust and hot firing test time of reference engines where reference engines have the same propellant and engine cycle with the new engine. In this paper, we provide a procedure to predict the engine reliability when the new engine and the reference engine have different propellant and engine cycles. The proposed method is illustrated to estimate the engine reliability of the first stage of Korea Space Launch Vehicle II.

A Fault Diagnosis of Damage on Inner Liner of Regeneratively-Cooled Combustion Chamber during Gas Generator Cycle Engine Hot Firing Test (가스발생기 사이클 엔진 연소시험 중 재생냉각형 연소기의 내피 손상진단)

  • Hwang, Dokeun;Kim, Hyeon-Jun;Kim, Jong-gyu;Kim, Munki;Lim, Byoungjik;Kang, Donghyuk;Joo, Seongmin;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1165-1168
    • /
    • 2017
  • This paper suggests a fault diagnosis of damage on inner liner of regeneratively-cooled combustion chamber during gas generator cycle rocket engine hot firing test. This method focuses on a phenomenon that fuel flow rate difference between two flow estimate methods changes under an inner liner damage of combustion chamber causing fuel leakage and it is expected that it contributes to detect a damage on the combustion chamber in early stage and prevent further destruction during the hot firing test.

  • PDF

Wear Simulation of Engine Bearings in the Beginning of Firing Start-up cycle (파이어링 시동 사이클 초기에서의 엔진 베어링 마모 시뮬레이션)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.35 no.4
    • /
    • pp.244-266
    • /
    • 2019
  • The purpose of this study is to estimate the wear volumes of engine journal bearings operating at variable angular velocity of a shaft in the beginning of firing start-up cycle. To do this, first we find the potential region of wear scar on engine journal bearings where the applied bearing load and crank shaft velocity are variable. The potential wear regions are discovered by finding minimum oil film thickness at every crank angle existing below most oil film thickness scaring wear (MOFTSW) obtained based on the concept of the centerline average surface roughness. Then we calculate the wear volume from the wear depth and two wear angles decided by the magnitude of each film thickness lower than MOFTSW at every crank angle. The results show that the expected wear region is located at a few bearing angles after and/or behind the upper center of a big-end bearing and the lower center of a main bearing. And the real wear region is similar to the estimated wear region. Further we find that the wear scar on an engine journal bearing may occur at re-starting time after switch-off of a start motor especially under the condition of high oil temperature.

Spontaneous Firing Characteristics of Cardiovascular Neurons in the Rostral Ventrolateral Medulla during Somatosympathetic Reflex . 11. Minimal Neuronal Model (상부복외측 연수 심혈관계 세포의 체성교감 반사시 자발적 흥분발사특성 분석 :II. 최소 세포망 모델)

  • Goo, Yong-Sook;No, Jin-A;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.79-84
    • /
    • 1996
  • A number of experimental evidences suggest that the rnun ventrolateral medulla(RVLM) is the final common pathway in the regulation of arterial blood pressure. A Voup of neurons in the RVLM, called the cardiovascular neurons (UN), show spontaneous activity temporally synchronized with the periodic cardiac cycle. These neurons affect the sympathetic nerve discharge(SND), thus are believed to be responsible for blood pressure control. The present experiment identified 98 UVNs in 42 cats based on the temporal relationships between each neuron's activity with both the cardiac cycle and SWD. In 20 UWL changes of spontaneous firing rate(FR) during the somatosympathetic reflex(SSR) were studied Five different firing patterns were observed during the pressor and depressor responses of SSR, implying that they form an interconnected neuronal circuit interacting with one another to generate efferent signals for blood pressure regulation. In the following companion paper, the firing patterns of CVN are analyzed to develop a minimal neuronal circuit model explaining the present experimental outcome.

  • PDF

Spontaneous Firing Characteristics of Cardiovascular Neurons in the Rostral Ventrolateral Medulla During Somatosympathetic Reflex : II. Minimal Neuronal Model (상부복외측 연수 심혈관계 세포의 체성교감반사시 자발적 흥분발사특성 분석 : I. 실험적 연구)

  • 차은종;구용숙;이태수
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.71-80
    • /
    • 1996
  • A number of experimental evidences suggest that the rnun ventrolateral medulla(RVLM) is the final common pathway in the regulation of arterial blood pressure. A Voup of neurons in the RVLM, called the cardiovascular neurons (UN), show spontaneous activity temporally synchronized with the periodic cardiac cycle. These neurons affect the sympathetic nerve discharge(SND), thus are believed to be responsible for blood pressure control. The present experiment identified 98 UVNs in 42 cats based on the temporal relationships between each neuron's activity with both the cardiac cycle and SWD. In 20 UWL changes of spontaneous firing rate(FR) during the somatosympathetic reflex(SSR) were studied Five different firing patterns were observed during the pressor and depressor responses of SSR, implying that they form an interconnected neuronal circuit interacting with one another to generate efferent signals for blood pressure regulation. In the following companion paper, the firing patterns of CVN are analyzed to develop a minimal neuronal circuit model explaining the present experimental outcome.

  • PDF

Hardness and microstructural changes by cooling rate and holding time during porcelain firing of a multi-purpose dental gold alloy (다목적용 치과용 금합금의 소성 시 냉각속도와 계류시간에 따른 경도와 미세구조의 변화)

  • Cho, Mi-Hyang
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.271-281
    • /
    • 2011
  • Purpose: The aim of this study is to investigate the changes in hardness and microstructure of a dental multipurpose alloy after simulated complete firing with controlled cooling rate and holding time by characterizing the changes in hardness and microstructure after simulated firing with various cooling rates and holding times. Methods: Before hardness testing, the specimens were solution treated and then were rapidly quenched into ice brine. The specimens were completely fired in furnace. Hardness measurements were made using a Vickers microhardness tester. The specimens were examined at 15 kV using a field emission scanning electron microscope. Results: The maximum hardness value was obtained at stage 0 after simulated firing with various cooling rates (quick cooling, stage 0, stage 1, stage 2, stage 3). By the repetitive firing, the hardness of the tested alloy decreased gradually. By holding the specimen at $500^{\circ}C$ for 10-20min after simulated firing, the hardness increased apparently. However, to hold the alloy for long periods of time in the relatively high temperature after simulated firing resulted in the formation of thick oxidation layer. The oxide film formed on the surface of the alloy after simulated complete firing with controlled cooling rate, which was mainly composed of O and Zn. Conclusion: It is reasonable to hold the alloy at $500^{\circ}C$ for 10-20min after complete firing in other to improve the final hardness of the alloy.

Combustion Characteristics of Technology Demonstration Model for Staged Combustion Cycle Engine (다단연소사이클 엔진 시스템 기술검증시제 연소성능 평가)

  • Im, Ji-Hyuk;Woo, Seongphil;Jeon, Junsu;Lee, Jungho;Lee, Kwang-Jin;Han, Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.108-111
    • /
    • 2017
  • High performance upper stage engine is necessary for space launch vehicles of geostationary orbit, and staged combustion cycle engine is suitable due to high specific impulse. Technology demonstration model for 9 tonf class staged combustion cycle engine, which is consisted of turbopump, preburner, combustion chamber and supply system, was assembled, and hot-firing test was conducted for three seconds in Upper-stage Engine Test Facility of Naro Space Center. Ignition, combustion and shut down of engine system was performed normally, and its performance parameters were evaluated.

  • PDF

EFFECT ON THE COLOR STABILITY OF STAINED PORCELAIN DUE TO TOOTH BRUSHING (잇솔질이 도재의 색 안정성에 미치는 영향)

  • Lee, Im-Gi;Jeong, Jun-Oh;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.172-183
    • /
    • 2002
  • This study is going to compare the degree of color change which occurs in the following two cases of the factors which cause the color change of extra-staining, one is during glazing by the dental technician, the other is tooth brush abrasion which makes the biggest influence on color change. To compare the degree of color change before and after glazing, a sample was made with vintage incisal porcelain No. 59 OPAL(Shofu Inc, Japan), after that it was painted with three colors of porcelain stainers, then the degree of color was measured with a spectrophometer(Model Chromaview 300, Spectoron Tech Co. Korea) after it had been treated with firing only and glazing after firing 40,000-cycle and 80,000-cycle of tooth brush abrasion test were carried out in order to simulate the brushing effect of 4 years and 8 years by using the abrasion tester. The colors were measured before the test, and after the 40,000-cycle and 80.000-cycle operations and the surfaces were examined by SEM. The results of this study were as follows ; 1. The color change before and after glazing was not great enough to have a clinical significance but the orange color was changed more significantly statistically than the blue and light brown(p<0.05). 2. In the case of the color change of stained porcelain by tooth brushing, carrying out staining and glazing with two-times firings resulted in statically less color change than one firing only(p<0.05). 3. In the case of the difference in the stainer's color, the orange color which has higher chroma was statically more sensitive than the blue color(p<0.05) 4. In the case of the color change after the 80,000-cycle abrasion, all showed color change when there was one firing and the orange stainer showed some color change with clinical significance when firings were done two times.