• 제목/요약/키워드: flat plate system

검색결과 344건 처리시간 0.027초

Unified equivalent frame method for flat plate slab structures under combined gravity and lateral loads - Part 2: verification

  • Choi, Seung-Ho;Lee, Deuck Hang;Oh, Jae-Yuel;Kim, Kang Su;Lee, Jae-Yeon;Shin, Myoungsu
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.735-751
    • /
    • 2014
  • In the previous paper, authors proposed the unified equivalent frame method (UEFM) for the lateral behavior analysis of the flat plate structure subjected to the combined gravity and lateral loads, in which the rotations of torsional members were distributed to the equivalent column and the equivalent slab according to the relative ratio of gravity and lateral loads. In this paper, the lateral behavior of the multi-span flat plate structures under various levels of combined gravity and lateral loads were analyzed by the proposed UEFM, which were compared with test results as well as those estimated by existing models. In addition, to consider the stiffness degradation of the flat plate system after cracking, the stiffness reduction factors for torsional members were derived from the test results of the interior and exterior slab-column connection specimens, based on which the simplified nonlinear push-over analysis method for flat plate structures was proposed. The simplified nonlinear analysis method provided good agreements with test results and is considered to be very useful for the practical design of the flat plate structures under the combined gravity and lateral loads.

태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구 (A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test)

  • 김미연;최병도;김형근;박진철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

플랫플레이트의 내진성능에 대한 수치해석 연구 (Numerical Study on Seismic Resistance of Flat Plate)

  • 박홍근;최경규;황영현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.971-976
    • /
    • 2001
  • Numerical studies were performed to investigate the seismic performance of Flat Plate System. For the numerical studies, a computer program for Finite Element analysis was developed. Parametric studies were performed to investigate variations of strength and ductility of flat plate with major parameters: gravity load, reinforcement ratio, thickness, column sizes. The numerical results provide a valuable insights on the behavior of flat plates. The comparison with the current design method shows that the current design methods for strength and ductility need to be improved in some aspects.

  • PDF

수평하중을 받는 테두리보가 있는 플랫플레이트 시스템의 유효보폭계수 (Effective Beam Width for Flat-Plate Systems Having Edge Beams under Lateral Loads)

  • 한상환;조자옥;박영미
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.213-219
    • /
    • 2008
  • 본 연구의 목적은 수평하중 하의 테두리보가 있는 플랫플레이트 시스템의 해석 방법을 제안 하는 것이다. 플랫플레이트 시스템은 보 없이 기둥이 직접 지지하는 구조로 정의되지만 일반적으로 설계에서는 테두리보를 설치하여 사용하고 있다. 수평하중 하의 플랫플레이트를 해석 할 수 있는 방법으로는 ACI 318 (2005)에서 유한요소법, 유효보폭법, 등가골조법을 제시하고 있다. 그 중 유효보폭법은 슬래브를 보요소로 치환함으로써 실용적인 해석이 가능하도록 하는 해석 방법이다. 유효보폭법에서의 보 요소는 슬래브와 같은 두께와 실제 슬래브에 대하여 어떠한 비율로 정의되는 유효보폭으로 정의된다. 그러나 유효보폭법에 관한 연구는 기하학적 변수에 대한 연구나 강성 감소 계수에 관한 연구가 일반적이고 테두리보를 고려해 줄 수 있는 유효보폭모델에 관한 연구는 아직 미미한 실정이다. 본 연구에서는 테두리보가 없는 플랫 플레이트 시스템의 횡 강성보다 테두리보가 있는 플랫플레이트 시스템의 횡 강성이 더 큰 강성을 확보하는 것을 검증하였다. 따라서 테두리보의 영향을 고려할 수 있는 플랫플레이트 시스템의 해석 방법이 제시되어야 할 필요가 있다고 판단된다. 본 연구에서는 수평하중에 대한 테두리보가 있는 플랫플레이트의 유효보폭모델을 제안하였다. 제안된 모델의 검증을 위하여 제안된 유효보폭모델의 결과값을 유한요소해석의 결과값과 비교하였다. 또한 제안된 유효보폭모델의 결과값과 기존에 수행된 실험의 결과와 비교하였다.

지역난방 적용 태양열시스템의 장기 열성능 분석 (Analysis of Long-term Thermal Performance of Solar Thermal System Connected to District Heating System)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.167-173
    • /
    • 2007
  • This study analyzed by simulation using TRNSYS as well as by experiment on the solar district heating system installed for the first time for the district heating system in Bundang. Simulation analysis using TRNSYS focused on the thermal behavior and long-term thermal efficiency of solar system. Experiment carried out for the reliability of simulation system. This solar system where the circuits of two different collectors, flat plate and vacuum tube collector, are connected in series by a collector heat exchanger, and the collection characteristics of each circuit varies. Therefore, these differences must be considered for the system's control. This system uses variable flow rate control in order to obtain always setting temperature of hot water by solar system. Specifically, this is a system that heats returning district heating water (DHW) at approximately $60^{\circ}C$ using a solar collector without a storage tank, up to the setting temperature of approximately $85{\sim}95^{\circ}C$ To realize this, a flat plate collector and a vacuum tube collector are used as separate collector loops. The first heating is performed by a flat plate collector loop and the second by a vacuum tube collector loop. In a gross collector area basis, the mean system efficiency, for 4 years, of a flat plate collector is 33.4% and a vacuum tube collector is 41.2%. The yearly total collection energy is 2,342GJ and really collection energy per unit area ($m^2$) is 1.92GJ and 2.37GJ respectively for the flat plate vacuum tube collector. This result is very important on the share of each collector area in this type of solar district heating system.

미세 Riblet 평판에서의 난류구조 변화에 관한 실험적 연구 (Experimental Study on Turbulent Structure of Flow over a Micro Riblet Plate)

  • 최용석;이상준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.375-376
    • /
    • 2006
  • Turbulent structure of a boundary-layer over a flat plate coated with micro riblet film(MRF) has been investigated experimentally. The turbulent structure was visualized using a dynamic particle image velocimetry (Dynamic PIV) system. We identified the vortex structures from 2-D velocity field data by applying the complex eigenvalue definition. The velocity field images acquired by using the complex eigenvalue definition showed the whole 2-D vortex structures clearly. In addition, the spatial distributions of small-scale vortices as well as large-scale vortices were obtained with high accuracy. The difference of vortex structures between the MRF coated flat plate and the smooth flat plate was analysed in detail. With varying upstream flow speed, the characteristics of vortex structure over the MRF coated flate plate was compared with those over the smooth flat plate.

  • PDF

플랫 플레이트-기둥의 외부 접합부의 변수 연구 (Numerical study on parameters of flat plate-column edge connections)

  • 안귀용;최경규;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.173-178
    • /
    • 2002
  • Flat plate is susceptible to punching shear failure at the slab-column connection, which may cause catastrophic structural collapse. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, since it is very difficult to experimentally simulate the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable information and data regarding to the strength and ductility of the flat plate-column edge connection. In the present study, numerical studies were performed for edge connections of continuous flat plate. The results were compared with the existing experiments, and the variations of bending moment, drift, effective width around the connection were investigated. Based on tile findings of the numerical studies, the disadvantages of current design methods were discussed.

  • PDF

플랫 플레이트-기둥 접합부의 내진성능에 대한 해석연구 (Numerical Study on Seismic Resistance of Flat Plate-Column Connections)

  • 박홍근;최경규;황영현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.891-896
    • /
    • 2002
  • Flat plate is susceptible to punching shear failure at the slab-column connection, which may cause catastrophic structural collapse. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, since it is very difficult to experimentally simulate the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable information and data regarding to the strength and ductility of the flat plate-column connection. In the present study, numerical studies were performed for interior connections of continuous flat plate. The results were compared with the existing experiments, and the variations of bending moment, shear, torsional moment around the connection were investigated. Based on the findings of the numerical studies, the disadvantages of current design methods were discussed.

  • PDF

포스트 텐션 플랫 플레이트 해석을 위한 강성감소계수 (Stiffness Reduction Factor for Post-Tensioned Flat Plate Slabs)

  • 박영미;박진아;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.125-126
    • /
    • 2009
  • 유효보폭 모델은 횡하중하의 포스트 텐션(PT) 플랫 플레이트 골조 해석에 사용된다. PT 플랫 플레이트의 정확한 해석을 위해서 슬래브의 강성감소는 정확하게 평가되어야 한다. 이 목적을 위하여 본 연구는 기존 연구자들의 PT 플랫 플레이트 실험체를 수집하였으며. 반복적인 작업으로 실험체 강성에 수렴하는 유효보폭모델의 강성을 찾기 위하여 슬래브 폭을 감소시켰다. 이러한 데이터를 수집하여 비선형 회귀분석을 통하여 PT 플랫 플레이트의 강성 감소 계수식을 제안하였다.

  • PDF

포스트 텐션 플랫 플레이트 외부 접합부의 이력 거동 (Cycle Behavior of Exterior Joint of Flat Plate Slab and Column)

  • 조종;하상수;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.239-242
    • /
    • 2005
  • The purpose of this research was focused on substantiating an effects of tendon-layouts and compressed stress($=f_{pc}$) induced by post-tensioning on seismic performance of post-tensioned flat plate slab-column connection designed as non-participating system. To accomplish this purpose, an experimental research of flat plate exterior slab-column connections subjected to gravity load and reversed lateral displacement history are presented. As a result, tendon-layout is a main variable to influence failure mechanism, dissipated energy and lateral deformation capacity. Furthermore, compressed stress ($=f_{pc}$) induced by post-tensioning enhanced the seismic performance of flat plate slab.

  • PDF