• Title/Summary/Keyword: flat-plate column connection

Search Result 68, Processing Time 0.032 seconds

Development for Connection Details between Flat Plate Slab and H-Steel Column (무량판 슬래브와 H형강 기둥 접합부 상세 개발)

  • Yoon, Myung-Ho;Lee, Yoon-Hee
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.22-27
    • /
    • 2014
  • The flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel column have been rare both at home and abroad. Recently high-rise residential and commercial buildings have been constructed in urban areas in Korea. The suggested dowel connection system is more likely to adoptable because it remarkably contribute to save inter story height and also to have many advantages compared with conventional steel works such as H-Steel frame + Deck plate slab system. This study aims at developing design method and program for connection between H-Steel column and flat plate slab system, which contribute to save significantly inter-story height.

A Study of Shear Reinforcement for Slab-Column Connection (슬래브-기둥 접합부의 전단보강상세에 관한 연구)

  • Baek, Sung-Woo;Kim, Jun-Seo;Choi, Hyun-Ki;Choi, Chang-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.37-40
    • /
    • 2008
  • The study is an experimental test on full-scale flat plate slab-column interior connection. The punching shear on the flat plate slab-column connection can bring about the reason of the brittle punching shear failure which may result of collapsing the whole structure. From the development of residential flat plate system, the shear reinforcement is developed for preventing the punching shear. For making sure of the punching shear capacity, developed for shear reinforcement in slab-column connection, the structural test is performed. The dimension of the slabs was 2620*2725*180mm with square column (600*800mm). The slabs were tested up to failure monotonic vertical shear forces. The presences of S/S bar and wire mesh substantially increased the punching shear capacity and the ductility of the slab-column connections.

  • PDF

Numerical study on parameters of flat plate-column edge connections (플랫 플레이트-기둥의 외부 접합부의 변수 연구)

  • 안귀용;최경규;박홍근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.173-178
    • /
    • 2002
  • Flat plate is susceptible to punching shear failure at the slab-column connection, which may cause catastrophic structural collapse. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, since it is very difficult to experimentally simulate the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable information and data regarding to the strength and ductility of the flat plate-column edge connection. In the present study, numerical studies were performed for edge connections of continuous flat plate. The results were compared with the existing experiments, and the variations of bending moment, drift, effective width around the connection were investigated. Based on tile findings of the numerical studies, the disadvantages of current design methods were discussed.

  • PDF

Numerical Study on Seismic Resistance of Flat Plate-Column Connections (플랫 플레이트-기둥 접합부의 내진성능에 대한 해석연구)

  • 박홍근;최경규;황영현
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.891-896
    • /
    • 2002
  • Flat plate is susceptible to punching shear failure at the slab-column connection, which may cause catastrophic structural collapse. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, since it is very difficult to experimentally simulate the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable information and data regarding to the strength and ductility of the flat plate-column connection. In the present study, numerical studies were performed for interior connections of continuous flat plate. The results were compared with the existing experiments, and the variations of bending moment, shear, torsional moment around the connection were investigated. Based on the findings of the numerical studies, the disadvantages of current design methods were discussed.

  • PDF

A Study on Strength of Plat-Plate Wall-Column Connections (Wall Column을 적용한 플랫플레이트 접합부 강도발현에 관한 연구)

  • Lee, Do-Bum;Park, Hong-Gun;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.257-266
    • /
    • 2006
  • Flat-plate building systems are utilized extensively for construction of apartments, hotels and office buildings because of short construction period, low floor-to-floor height and flexibility in plan design. Recently, to increase lateral seismic resistance of flat-plate building systems, wall-columns are used frequently. Therefore, to estimate strength of flat-plate column connection accurately, the effect of column section shape on the behavior of flat-plate column connection should be considered properly, In the present study, a numerical analysis was performed for interior connections of continuous flat-plate to analyze the effect of column section shape. For the purpose, a computer program for nonlinear FE analysis was developed, and the validity was verified. Through the parametric study, the variations of shear stress distribution around the connection were investigated. According to the result of numerical analysis, as the length of the cross section of column in the direction of lateral load increases, the effective area and the maximum shear strength providing the torsional resistance decrease considerably. Therefore, these effects should be considered properly to estimate the strength of flat-plate connection accurately.

Punching Shear Strength of CFT Column to RC Flat Plate Connections Reinforced with Shearhead (전단머리 보강 CFT기둥-RC 무량판 접합부의 펀칭전단강도)

  • Kim, Jin-Won;Lee, Cheol-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.423-433
    • /
    • 2012
  • This paper summarizes full-scale gravity-load test results on CFT column-to-RC flat plate connections reinforced with shearhead. CFT construction has many structural and constructional advantages over conventional steel and RC column construction and is gaining wide acceptance. Meanwhile the use of RC flat plate system in the basement and residential floors of tall buildings is often mandatory to reduce story height and enable rapid construction in domestic practice. Combining CFT column and flat plate floor is expected to result in further rapid construction. However, the issues related to connecting CFT column to RC flat plate have not been fully addressed yet. Several promising connecting schemes by using steel shearhead were proposed and tested in this study. Test results showed that the proposed connection can exhibit the punching shear strength higher than RC flat plate counterparts. An empirical formula that can reasonably predicts the punching shear strength of the proposed connection was also proposed.

Cycle Behavior of Exterior Joint of Flat Plate Slab and Column (포스트 텐션 플랫 플레이트 외부 접합부의 이력 거동)

  • Cho Jong;Ha Sang Su;Han Sang Whan;Lee Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.239-242
    • /
    • 2005
  • The purpose of this research was focused on substantiating an effects of tendon-layouts and compressed stress($=f_{pc}$) induced by post-tensioning on seismic performance of post-tensioned flat plate slab-column connection designed as non-participating system. To accomplish this purpose, an experimental research of flat plate exterior slab-column connections subjected to gravity load and reversed lateral displacement history are presented. As a result, tendon-layout is a main variable to influence failure mechanism, dissipated energy and lateral deformation capacity. Furthermore, compressed stress ($=f_{pc}$) induced by post-tensioning enhanced the seismic performance of flat plate slab.

  • PDF

Structural Performance of Column-Slab Connection in Flat Plate System Using High Strength Concrete (고강도 콘크리트를 사용한 플랫 플레이트 구조의 기둥·슬래브 접합부 구조성능)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.97-105
    • /
    • 2006
  • The reinforced concrete flat plate system provides architectural flexibility, clear space, reduced building height, simple formwork, which consequently enhance constructibility. One of the serious problem in the flat plate system is brittle punching shear failure due to transfer of shear force and unbalanced moments in column-slab connection. Since the use of high strength concrete recently has become in practice for reinforced concrete structures, it is highly desired to establish the structural design method for flat plate construction using high strength concrete. In this paper, interior column-slab connection constructed with high strength concrete were tested under lateral and gravity loads to evaluate their strength and behavior. The test parameters were slab reinforcement ratio and the gravity load levels.

Numerical Study on Interior Flat Plate-Column Connections Subjected to Unbalanced Moment (불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부에 대한 해석연구)

  • 최경규;황영현;박홍근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.949-960
    • /
    • 2002
  • Flat plate structures under lateral load are susceptible to punching shear failure of the slab-column connection. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, due to complexity in the behavior and difficulty in simulating the actual load and boundary conditions of the flat plate system, it is not easy to obtain reliable data regarding to the strength and ductility from the previous experimental studies. In the present study, a numerical study was performed for interior connections of continuous flat plate. For the purpose, a computer program for nonlinear FE analyses was developed, and the validity was verified by comparisons with the existing experimental results. Through the parametric studies, the variations of bending moment, shear, and torsional moment around the connection were investigated. Based on the findings of the numerical studies, the aspects which need to be improved in current design methods were discussed. The results of the present study will be used for developing a design method for the flat plate-column connection in the companion paper.

Strength of Exterior Flat Plate-Column Connections Subjected to Unbalanced Moment (불균형 휨모멘트를 받는 플랫 플레이트-기둥 외부접합부의 강도)

  • Choi, Kyoung-Kyu;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.470-481
    • /
    • 2003
  • Exterior plate-column connection has an unsymmetrical critical section for eccentric shear of which perimeter is less than that of interior connection, and hence, around the connection, unbalanced moment and eccentric shear are developed by both gravity load and lateral loads. Therefore, exterior connection is susceptible to punching shear failure. Current design provision cannot accurately explain strength of existing experiments, partly due to the complexity in the behavior of exterior plate-column connection, or partly due to the theoretical deficiency of the strength analysis model adopted. In the present study, nonlinear finite element analyses were performed for exterior connections belonging to continuous flat plate. For each direction of lateral load, the behavior and strength of exterior plate-column connection were quite different. Based on the numerical result, strength prediction model for exterior connection was proposed for each direction of lateral load. Compared with existing experiments, the proposed method was verified.