• Title/Summary/Keyword: flexible micro-actuator

Search Result 15, Processing Time 0.023 seconds

Robust motion control of a flexible micro-actuator using $H_{\infty}$ control method

  • Okugawa, Masayuki;Sasaki, Minoru;Fujisawa, Fumio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.397-400
    • /
    • 1996
  • In this paper, robust motion control of a flexible micro-actuator is presented. The actuator is made of a bimorph piezoelectric high-polymer material (PVDF). No mathematical model system can exactly model a physical system such a flexible micro-actuator. For this reason we must be aware of how modeling errors might adversely affect the performance of a control system for such a model. The H method addresses a wide range of the control problems, combining the frequency and time domain approaches. The design is an optimal one in the sense of minimization of the maximum of the closed-loop transfer function. It includes colored measurement and process noise. It also addresses the issues of robustness due to model uncertainties, and is applicable to the, flexible micro-actuator control problem. Therefore, we adopt the H control problem to the robust motion control of the flexible micro-actuator. Theoretical and experimental results demonstrate the satisfactory performance and the effectiveness of the designed controller. the effectiveness of the designed controller.

  • PDF

Precise contact force control of a flip chip mounting head system

  • Shim, Jaehong;Cho, Youngim;Oh, Yeontaek
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.109.1-109
    • /
    • 2002
  • This paper presents a macro/micro flip chip mounting head system for precise force control. In the proposed macro/ micro system, the macro actuator is conventional do servomotor with a ball screw mechanism and the micro actuator is a voice coil motor(VCM) that consists of four NdFeB magnets and a winded moving coil. For force control, a sensitive strain-gauge force sensor is mounted in the micro actuator. Through harmonic motion between macro and micro actuator, we would like to get precise contact force control when small sized flip chip is mounted on flexible substrate in high speed. In order to show the effectiveness of the proposed macro/micro flip chip mounting head system, we com...

  • PDF

Fabrication of Bending Actuator for Micro Active Catheter (초소형 작동형 내시경용 Bending 액츄에이터의 제작)

  • Lee, Kwang-Ho;Lee, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.615-617
    • /
    • 1997
  • This paper reports experimental results on the fabrication and analysis of millimeter-sized bending actuators for active catheter by use of the shape memory alloy spring and the flexible beam. The major components of micro actuator are shape memory alloy spring, stainless steel strip and two acryl links. The micro actuator with the diameter of 2.0 mm and the length of 25 mm has been fabricated and characterized for the possible application to the micro active catheters. The measured maximum angle is $60^{\circ}$ and the response time is 5 sec.

  • PDF

The Control of a flexible Robotic Finger Driven by PZT (압전소자로 구동되는 유연성 로봇 핑거의 제어)

  • 류재춘;박종국
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.568-576
    • /
    • 1998
  • In this thesis discuss with a flexible robotic finger design and controller which is used for the micro flexible robotic finger. So, miniaturization, precision, controller for the control of grasping force and actuator were needed. And, even if we develop a new actuator and controller, in order to use on real system, we must considerate of a many side problem. In a force control of micro flexible finger for grasping an object, the fingertip's vibration was more important task of accuracy control. And, controller were adopt the PD/PI mixed type fuzzy controller. The controller were consist of two part, one is a PD type fuzzy controller for increase the rising time response, the other is a PI type fuzzy controller for decrease of steady-state error. Especially, in a PD type fuzzy controller, we used only seven rules. And, for a PI controller, we adopt a reset factor for the control of input values. so, we have overcome the exceed of controller's input range. For the estimate of ontroller's utility and usefulness, we have experiment and computer simulation of three cases. First, we consider of unit force grasping control for a task object, which is 0.03N. Second, bounding grasping force control which is add to a sinusoidal force on the unit force. At this cases the task force is (0.03+0.01 sin wt N). And consider of following of rectangular forces.

  • PDF

Analysis of Dynamic Characteristics on the L/UL Ramp Using Advanced FE Model (FE모델을 사용하여 램프상의 로드-언로드 동적특성에 대한 해석)

  • Jung, Moon-Gyo;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.413-418
    • /
    • 2004
  • Recently, the development of mobile devices demands information storage systems to use micro drive devices. 1-inch micro drive hard disk uses the load/unload(L/UL) technology to increase area recording density and reduce power consumption. Because micro drive has light actuator, effects of the flexible cable that is ignored in 3.5-inch hard disk drive is important to load/unload performances. In this paper, effects of flexible cable on load/unload performances are studied.

  • PDF

Movement characteristics of pneumatic actuators for the semi-autonomous colonoscopic system (자율이동 대장 내시경을 위한 공압구동기의 이동 특성)

  • Kim, Byung-Kyu;Lee, Jin-Hee;Park, Ji-Sang;Lim, Young-Mo;Park, Jong-Oh;Kim, Soo-Hyun;Hong, Yeh-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.295-300
    • /
    • 2001
  • In recent years, as changing the habit of eating, the pathology in the colon grows up annually. For that reason, the colonoscopy is generalized. But it requires much time to acquire a dexterous skill to perform an operation. And the procedure is painful to the patient. Therefore, biomedical and robotic researchers are developing a locomotive colonoscope that can travel safely in colon. In this paper, we propose a novel design and concept of semi-autonomous colonoscope and two actuators for the micro robot. The micro robot comprises camera and LED for diagnosis, steering system to pass through the loop, pneumatic actuator and bow-shaped flexible supporters to control a contact force and to keep the space between colon wall and the actuator. For actuating mechanism, we suggest two models. One is based on the reaction force, and the other is impact force. In order to validate the concept and the performance of the actuators, we carried out the preliminary experiments in rigid pipes.

  • PDF

Stability analysis of piezopolymer flexible twisting micro-actuator with a linear feedback control

  • Sasaki, M.;Wang, P.K.C.;Fujisawa, F.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.197-201
    • /
    • 1993
  • A method for the closedloop control of the torsional tip motion of a piezo-polymer actuator is presented. The application of Lyapunov's direct, method to the problem is explored. A feedback control of the torsional tip motion of tile piezopolymer actuator is derived by considering tile time rate of change of the total energy of the system. If the angular velocity of the tip of the actuator is known, all the modes of tile actuator can be controlled simultaneously. This approach has tile advantage over the conventional methods in the respect that it allows one to directly with tile system's partial differential equations without resorting to approximations.

  • PDF

Design of flexure hinge to reduce lateral force of laser assisted thermo-compression bonding system (레이저 열-압착 본딩 시스템의 Lateral Force 감소를 위한 유연 힌지의 설계)

  • Lee, Dong-Won;Ha, Seok-Jae;Park, Jeong-Yeon;Yoon, Gil-Sang
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.23-30
    • /
    • 2020
  • Laser Assisted Thermo-Compression Bonding (LATCB) has been proposed to improve the "chip tilt due to the difference in solder bump height" that occurs during the conventional semiconductor chip bonding process. The bonding module of the LATCB system has used a piezoelectric actuator to control the inclination of the compression jig on a micro scale, and the piezoelectric actuator has been directly coupled to the compression jig to minimize the assembly tolerance of the compression jig. However, this structure generates a lateral force in the piezoelectric actuator when the compression jig is tilted, and the stacked piezoelectric element vulnerable to the lateral force has a risk of failure. In this paper, the optimal design of the flexure hinge was performed to minimize the lateral force generated in the piezoelectric actuator when the compression jig is tilted by using the displacement difference of the piezoelectric actuator in the bonding module for LATCB. The design variables of the flexure hinge were defined as the hinge height, the minimum diameter, and the notch radius. And the effect of the change of each variable on the stress generated in the flexible hinge and the lateral force acting on the piezoelectric actuator was analyzed. Also, optimization was carried out using commercial structural analysis software. As a result, when the displacement difference between the piezoelectric actuators is the maximum (90um), the maximum stress generated in the flexible hinge is 11.5% of the elastic limit of the hinge material, and the lateral force acting on the piezoelectric actuator is less than 1N.

Mechanical and Electrical Properties of Electrospun CNT/PVDF Nanofiber for Micro-Actuator (미세-작동기를 위한 전기방사 CNT/PVDF 나노섬유 기반의 탄소 복합재의 기계적 및 전기적 특성 평가)

  • Gu, Ga-Young;Wang, Zuo-Jia;Kwon, Dong-Jun;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.1
    • /
    • pp.14-20
    • /
    • 2013
  • The electrospun PVDF containing CNT was made for fabricating materials of the actuator. The electrochemical and their actuating movement were evaluated for the actuator performance in the electrochemical environment. The actuator (which was fabricated by electrospinning) had some advantages, i.e., good dispersion and flexible properties. In the electrospinning process, the final product would have different forms based on different essential factors. In this work, electrospun nanofibers were aligned by using the drum-type collector, and the morphology was identified via the field emission-scanning electron microscope (FE-SEM). The uniform dispersion of CNT in PVDF nanofiber was observed by electron probe X-ray micro-analysis (EPMA) test. The results of tensile strength and electrical resistivity provided the aligned state. The electrospun CNT/PVDF nanofiber sheet on the aligned direction showed better mechanical and electrical properties than the case of the vertically-aligned direction. The efficiency and electrical capacities of electrospun CNT/PVDF nanofiber sheets were compared with the cast PVDF sheet for actuator application. Electrospun CNT/PVDF nanofiber sheet exhibited much better the case of actuator performance than cast neat PVDF actuator, due to the excellent electrical connecting areas.

Wirelessly Driven Cellulose Electro-Active Paper Actuator: Application Research (원격구동 셀룰로오스 종이 작동기의 응용연구)

  • Kim, Jae-Hwan;Yang, Sang-Yeol;Jang, Sang-Dong;Ko, Hyun-U;Mun, Sung-Cheol;Kim, Dong-Gu;Kang, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.539-543
    • /
    • 2012
  • Cellulose Electro-Active Paper (EAPap) is attractive as a biomimetic actuator because of its merits: it is lightweight, operates in dry conditions, has a large displacement output, has a low actuation voltage, and has low power consumption. Cellulose is regenerated so as to align its microfibrils, which results in a piezoelectric paper. When chemically bonded and mixed with carbon nanotubes, titanium oxide, zinc oxide, tin oxides, the cellulose EAPap can be used as a hybrid nanocomposite that has versatile properties and that can meet the requirements of many application devices. This paper presents trends in recent research on the cellulose EAPap, mainly on material preparation and its use in devices, including biosensors, chemical sensors, flexible transistors, and actuators. This paper also explains wirelessly driving technology for the cellulose EAPap, which is attractive for use in biomimetic robotics and micro-aerial vehicles.