• Title/Summary/Keyword: flux cored wire

Search Result 54, Processing Time 0.023 seconds

Effect of wear of Contact Tips to Welding Consumable for Gas Metal Arc Welding (가스메탈아크용접에서 콘택트팁의 마모에 미치는 용접재료의 영향)

  • Kim, In-Gyu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.860-864
    • /
    • 2012
  • The contact tip is higher the wear of resistance and the longer life are demanded to GMA welding process. In this study, four different contact tips with three different compositions by two wires were evaluated their wear resistance by measuring in every one hour the area of enlarged hole at the exit side during actual wleding. Experimental results clearly showed that the Cr-containing tips strengthened by precipitation hardening have much better resistance to wear than those made by work hardening. In addition, flux cored wire is excellent abrasion resistance test results showed. Based on these results, the domestic industry, the life of the contact tip to know will be used as basic data.

Effects of gas formers of flux cored wire on spattering (FCW의 가스 발생제가 스패터링에 미치는 영향)

    • Journal of Welding and Joining
    • /
    • v.16 no.5
    • /
    • pp.93-99
    • /
    • 1998
  • Effects of gas formers of MgCO$_3$, CaCO$_3$ and Li$_2$CO$_3$ on the spattering phenomena were investigated for non-shielded flux cored arc welding. Spattering phenomena were pictured using high speed camera as a speed of 3000 frames per sec. As experimental results, spattering modes were classified into 4 types. The modes were spattering by arc force, gas explosion, short circuit and pore escape. The amount of spatters by arc force was 30%, gas blowing force was 40%, short circuit 10%, pore escape was 10% and others were 10%. When Li$_2$CO$_3$ was added, the amount of spatters was largest, and it decreased in the order of CaCO$_3$ and MgCO$_3$.

  • PDF

A Study on Fume Formation Ratio on Flux Cored Arc Welding Process (플럭스 코어드 아크 용접 공정에서의 흄 형성량에 관한 연구)

  • Yoon, Chung-Sik;Paik, Nam-Won
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.108-112
    • /
    • 1999
  • A study was conducted for the effects of input energy on fume formation ratios based on electrode(FFR$_{electrode}(g/kg_{electrode})),\;deposited\;metal(FFR_{weld}(g/kg_{weld}))\;and\;slag(FFR_{slag}(g/kg_{slag}))\;at\;CO_2$ flux cored arc welding on stainless steel. Experiments were run in well designed welding fume box. Six types of flux cored wires were used and three levels of current and voltages were given. The measured values of $FFR_{electrode},\;FFR_{weld},\;FFR_{slag}\;are\;7.90{\pm}1.47\;g/kg_{electrode},\;9.18{\pm}1.65\;g/kg_{\electrode},\;71.8{\pm}24.2\;g/kg_{slag}$ respectively. Fume formation ratios are not increased dramatically by input energy because of simultaneous increasing of melted electrodes, deposited metal and slag. The results indicate that the test of fume formation ratios in the research on production of low fume welding wire can be run at the fixed condition of input energy rather than various condition.

  • PDF

A Study on the Effect of Heat Input on the Microstructure and Toughness of Weldments Made by Domestic Flux Cored Wires. (국산 플럭스 코어드 와이어 용접에서 입열량이 용접부의 미세조직과 인성에 미치는 영향)

  • 고진현;국정한
    • Journal of Welding and Joining
    • /
    • v.11 no.4
    • /
    • pp.57-69
    • /
    • 1993
  • In the present study, the microstructure and Charpy V notch toughness of multipass $CO_2$ FCA weldment in three different heat inputs(1-3KJ/mm)were investigated. The weldments using two different domestic FCAW wires(AWS E71T-1 and E71T-5 equivalent) in C-Mn steel were chemically analysed. The following conclusions can be inferred. 1. T-1 wire Showed a stable arc transfer, less spatter and harsh, a better bead spreading and easy slag removal, whereas T-5 wire suffered from the arc stability, which tended to increase spatter and produce a more convex bead. 2.The microsturctures of the top beads of the weldments in three different heat inputs consisted of coarse-grained boundary ferrite and Widmanstatten ferrite side plate with increasing heat inputs. The modest fraction of acicular ferrite in the two wire weldments was observed in the 2KJ/mm heat input. 3.The fine-grained reheated zones of both welds consisted of a duplex microstructure of polygonal ferrite and second phases. 4. The basic flux weldment of T-5wires showed a higher Charpy impact property than that of T-1 wires because of a higher fraction of acicular ferrite in the weld microstructure.

  • PDF

Effects of Welding Parameters on Diffusible Hydrogen Contents in FCAW-S Weld Metal (셀프실드아크 용접금속의 확산성수소량에 미치는 용접변수의 영향)

  • Bang, Kook-Soo;Park, Chan
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.77-81
    • /
    • 2013
  • The effects of the welding parameters, contact tip-to-workpiece distance (CTWD), current, and voltage on the diffusible hydrogen content in weld metal deposited by self-shielded flux cored arc welding were investigated and rationalized by comparing the amount of heat generated in the extension length of the wire. This showed that as CTWD increased from 15mm to 25mm, the amount of heat generated was increased from 71.1J to 174.8J, and the hydrogen content was decreased from 11.3mL/100g to 5.9mL/100 g. Even if little difference was observed in the amount of heat generated, the hydrogen content was increased with an increase in voltage because of the longer arc length. A regression analysis showed that the regression coefficient of voltage in self-shielded flux cored arc welding is greater than that in $CO_2$ arc welding. This implies that voltage control is more important in self-shielded flux cored arc welding than in $CO_2$ arc welding.

Effect of Flux Type on Arc Characteristic of FCA Welding (FCA 용접의 아크현상에 미치는 Flux Type의 영향)

  • 강성원;오은식;유덕상;안영호
    • Journal of Welding and Joining
    • /
    • v.17 no.1
    • /
    • pp.116-123
    • /
    • 1999
  • The $CO_2$ welding with 100% $CO_2$ shielding gas is commonly used because of its cost and efficiency. Arc phenomena of the $CO_2$ welding is influenced by various factors such as chemical compositions of welding wire, shielding gas, welding condition and welding power source etc. In this study, arc phenomena is investigated by using two type of FCW(titania type, semi-metal type). Then, the welding quality and optimum welding condition can be selected. From this study, the following results were obtained; 1) In low current range(140A), FCW up to welding voltage(22V) resulted in a typical short circuit transfer. 2) In high current range(320A), the arc stability in titania FCW of a typical globular transfer is better than that of semi-metal FCW.

  • PDF

A Study on the Effect of Welding Conditions on Fume Generation Rate in $CO_2$ Flux Cored Arc Welding ($CO_2$ FCAW에서 용접조건이 Fume발생량에 미치는 영향에 관한 연구)

  • 채현병;김정한;김희남
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.87-95
    • /
    • 1998
  • The use of flux cored arc welding(FCAW) process has grown dramatically since it has been developed because of the remarkable operating characteristics and the resulting weld properties. The feature that distinguishes the FCAW process from other arc welding processes is the enclosure of fluxing ingredients within a continuously fed tubular electrode. The benefits of FCAW process are the increased productivity due to continuous wire feeding, the metallurgical effects derived from the reactions with flux, and the shapes of weld bead formed by slag. However, FCAW process causes the problem in working environment because it generates much more fume than other welding processes. Recently, the welding fume became a hot issue in the field after some welders were diagnosed as manganese toxcosis and siderosis. This study was started to investigate the characteristics of welding fume and utilize the results from the investigation to protect the welders from welding fume. As a first step, the effect of welding conditions on the fume generation rate(FGR) were investigated during FCAW process with $CO_2$ shielding. The considered welding conditions were welding current, arc voltage, travel speed, contact tube to work distance, and torch angle. The results showed that FGR was affected by all of these factors.

  • PDF

Review on Flux Cored Wire Development for Welding Fume Reduction (용접 Fume 저감을 위한 용접재료의 개발 동향)

  • 한종만
    • Journal of Welding and Joining
    • /
    • v.16 no.1
    • /
    • pp.49-51
    • /
    • 1998
  • 최근 포항공단 내 철 구조물 용접작업자가 Mn에 의한 뇌병변이 국내 최초로 발견되어 CO$_{2}$ 용접시 발생하는 Mn Fume에 기인한 것으로 의심을 하고 있으며, 이 문제가 언론을 비롯한 관련기관에서 쟁점화 된 바가 있지만 확실한 결론이 도출된 것으로는 보이지 않는다. 본 고에서는 CO$_{2}$ 용접 시 Fume의 발생 기구 및 이의 영향에 대한 검토와 용접 Fume을 줄일 수 있는 용접재료 측면에서의 대책과 현황에 대해 검토하고자 한다.

  • PDF