• 제목/요약/키워드: flux-meter

검색결과 100건 처리시간 0.023초

화염으로부터의 복사 열유속의 계측 I (A study on the measurement of Radiative Heat flux form the flame(I) -Design and Calibration of a Heat flux meter-)

  • 정종수;인종수;김승수
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.484-491
    • /
    • 1990
  • A heat-flux meter has been designed and manufactured to measure the heat flux from the flame. A calibration method of the heat-flux meter by a calibration furnace has also been proposed. The k-type (Chromel-Alumel) thermocouple material has been used as the material for the beat-flux meter. The electormotive force (e.m.f.) from the K-type thermocouple is shown to be linearly proportional to the heat flux absorbed. The characteristics of the heat-flux meter become better as the radius of heat absorbing disk becomes larger and its thickness thinner.

Drift Self-compensating Type Flux-meter for Automatic Magnetic Flux Measurement

  • Ga, E.M.;Son, D.;Bak, J.G.;Lee, S.G.
    • Journal of Magnetics
    • /
    • 제8권4호
    • /
    • pp.160-163
    • /
    • 2003
  • In magnetic flux measurement, output voltage drift of electronic integrator is an essential problem. In this work, we have developed a new kind of Miller type integrator using a sample and hold amplifier. Input bias current was measured and this value was hold in the sample and hold amplifier, after that input bias current of Miller integrator was compensated automatically using the value which holds in the sample and hold amplifier. Developed flux-meter shows the drift of flux-meter are smaller than 10$^{-5}$ Wb/min in full scale of 10$^{-2}$, and we could also measure multi-channel magnetic flux simultaneously.

Digital Sample and Hold 증폭기를 사용한 드리프트 자체 보상형 자속계의 제작 (Drift Self-compensating type Flux-meter Using Digital Sample and Hold Amplifier)

  • 가은미;손대락
    • 한국자기학회지
    • /
    • 제15권6호
    • /
    • pp.332-335
    • /
    • 2005
  • 자속계의 경우 입력전압을 적분하여야 되기 때문에 연산증폭기의 입력 바이어스 전류가 있으면 적분기의 출력이 드리프트하게 된다. 본 연구에서는 이 드리프트를 자동으로 측정하고 보상하기 위하여 전압변동이 없는 디지털 sample and hold증폭기를 자속계에 도입하여 제작하였다. 개발한 자속계의 경우 적분기의 시간상수 $RC=10^{-3}$ s에서 드리프트가 $5{\times}10^{-8}\;Wb/s$ 이하였다.

금속스크랩이 혼합된 상변화물질의 유효열전도율 (Effective thermal conductivity of the phase change material with metal scrap)

  • 김시범;노승탁
    • 대한기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.923-928
    • /
    • 1986
  • 본 논문에서는 열전도율이 큰 금속의 스크랩과 파라핀을 혼합한 축열 매질에 있어서 스크랩의 체적 혼합율에 따르는 열전도율의 변화를 모델링과 실험으로 구해서 축열 계산에 필요한 열전도율 자료를 제시하고자 한다.

펠티어 소자를 사용한 Low Drift Flux Meter의 기초연구 (A Basic Study on the Low Drift Flux Meter by Using a Peltier Device)

  • 김철한;허진;신광호;사공건
    • 한국전기전자재료학회논문지
    • /
    • 제14권11호
    • /
    • pp.912-916
    • /
    • 2001
  • Fluxmeter is a measuring instrument the magnetic flux intensity by means of an integration of the voltage induced to a search coil to unit time. It also is required to a precise integrator since the voltage induced to a search coil has a differential value of the flux ${\Phi}$ to unit time. In this study, a bias current which is a main problem of the integrator in a drift troublesome depending on the temperature of a FET is investigated. We have confirmed that the temperature dependence of both the bias current of a integrator using the FET and the reversal saturated current of the minor carrier in a P-N junction of a semiconductor were the same. The property of a commercial integrator goes rapidly down with increasing temperature. The bias current of a FET is increased twice as much with 10$^{\circ}C$ increment. As a result, the low drift integrator could be developed by setting the lower temperature up with a pottier device.

  • PDF

냉장고 진공단열재 성능진단을 위한 열유속계 위치에 관한 연구 (A Study on the Heat Flux Meter Location for the Performance Test of a Refrigerator Vacuum Insulation Panel)

  • 하지수
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.471-476
    • /
    • 2013
  • The present study has been carried out to elucidate the optimal method for the performance test of a refrigerator vacuum insulation panel (VIP), by using numerical heat transfer analysis. Three locations of heat flux meter have been tested, for deriving the best test method to clarify the normal or the abnormal condition of the vacuum insulation panel in a refrigerator. The first location of the heat flux sensor is at the same place as the heater, the second one is at the nearby side location of the heater and the third one is at the opposite side location of heater in the refrigerator. The heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$ were calculated for the cases with the normal VIP, and with the abnormal VIP, and their differences analyzed. From the present study, the first and the second method had a mere difference characteristics of heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$, between the cases with the normal or the abnormal VIP. The magnitude of the heat flux after 300sec had a great difference between the cases with the normal or abnormal VIP for the third method, and it could be considered the most optimal method to test the performance of a refrigerator vacuum insulation panel.

이산화탄소가 수소 산소부화 화염의 열전달에 미치는 영향 (Effects of CO2 on Heat Transfer from Oxygen-Enriched Hydrogen Flame)

  • 이창엽;최준원;백승욱
    • 대한기계학회논문집B
    • /
    • 제28권8호
    • /
    • pp.937-944
    • /
    • 2004
  • An experimental study has been conducted to evaluate the effects of $CO_2$ on heat transfer from oxygen-enriched hydrogen flame. Experiments were performed on flames stabilized by a co-flow swirl burner, which was mounted on top of the furnace. Five different oxidizer compositions were prepared by replacing $N_2$ with $CO_2$. In a steady state, the total as well as radiative heat flux from the flame to the wall of furnace have been measured using a heat flux meter. Temperature distribution in furnace also has been measured and compared. By increasing $CO_2$ proportion in the oxidizer, the convection played a more significant role rather than radiation. Overall temperature in the furnace was seen to be decreased, while the total heat flux has increased.

플럭스미터와 단공희석시험을 이용한 카르스트 대수층 내 지하수 플럭스 측정 비교 (Comparison between Passive Flux Meters and Borehole Dilution Tests to Estimate Groundwater Flux in a Karst Aquifer)

  • 이주연;양민준
    • 자원환경지질
    • /
    • 제53권5호
    • /
    • pp.543-552
    • /
    • 2020
  • 본 연구는 플로리다 주 Silver Springs 유역 내 카르스트 대수층의 지하수 플럭스를 측정하기 위해 플럭스미터(passive flux meter)와 단공희석시험(borehole dilution test)을 수행하였다. 또한 카르스트 대수층 내 분포하는 두 영역인 암반 매질(matrix)과 균열암반 매질(non-matrix)에 따른 플럭스미터의 성능도 함께 평가하였다. 그 결과 유속이 낮은 암반 매질 영역에서는 플럭스미터의 측정값(5.96 ± 1.75 cm/day)이 단공희석시험의 측정값(4.68 ± 2.99 cm/day)과 유사하게 나타났다. 반면, 유속이 빠른 균열암반 매질 영역에서는 플럭스미터의 측정값(9.94 ± 0.90 cm/day)과 단공희석시험의 측정값(1817.37 ± 1795.50 cm/day)이 큰 차이를 보였다. 이와 같은 결과는 지하수가 플럭스미터 내부 흡착제를 완전히 통과한다고 가정하였으나, 빠른 지하수 플럭스(>11 cm/day)를 가진 균열암반 매질 영역의 경우 지하수가 플럭스미터의 활성탄 담체를 통과하지 못하고 플럭스미터와 관측공 사이의 공간으로 우회하여 흐르기 때문으로 판단된다. 따라서 기존의 플럭스미터는 11 cm/day 이하의 지하수 플럭스 측정에 적합하며, 지하수 플럭스가 11 cm/day 이상인 대수층에서 사용할 수 있는 새로운 플럭스미터의 개발이 필요할 것으로 생각된다.

파라메터 추정을 통한 유도전동기의 고정자 자속 기준 벡터 제어 (Stator Flux Vector Control Of Induction Motor using Parameter Estimation)

  • 함년근;전기영;김성남;이승환;이훈구;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2123-2125
    • /
    • 1997
  • In the induction motor control, the rotator flux estimation methods are used in the implement vector control of the induction motor instead of the potentical-meter or tacho-meter, a system is very sensitive in noise. In this paper, the parameters that do not affect the stablity of the system were applied in Off-Line tuning methods. In case of the rotator resistor that is sensitive. On-Line tuning methods applied in the steady state. We ascertained that the utility of a theory applied in stator flux orientation vector control through the simulation.

  • PDF

XIC tools을 사용한 고온 초전도 Rapid Single Flux Quantum 1-bit A/D Converter의 Simulation과 회로 Layout (Simulations and Circuit Layouts of HTS Rapid Single Flux Quantum 1-bit A/D Converter by using XIC Tools)

  • 남두우;홍희송;정구락;강준희
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.131-134
    • /
    • 2002
  • In this work, we have developed a systematic way of utilizing the basic design tools for superconductive electronics. This include WRSPICE, XIC, margin program, and L-meter. Since the high performance analog-to- digital converter can be built with Rapid Single Flux Quantum (RSFQ) logic circuits the development of superconductive analog-to-digital converter has attracted a lot of interests as one of the most prospective area of the application of Josephson Junction technology. One of the main advantages in using Rapid Single Flux Quantum logic in the analog-to-digital converter is the low voltage output from the Josephson junction switching, and hence the high resolution. To design an 1-bit analog-digital converter, first we have used XIC tool to compose a circuit schematic, and then studied the operational principle of the circuit with WRSPICE tool. Through this process, we obtained the proper circuit diagram of an 1-bit analog-digital converter circuit. Based on this circuit we performed margin calculations of the designed circuits and optimized circuit parameters. The optimized circuit was laid out as a mask drawing. Inductance values of the circuit layout were calculated with L-meter. Circuit inductors were adjusted according to these calculations and the final layout was obtained.

  • PDF