The Influence of Various Carrying a Pack Methods during Walking on Parameters of Foot Contact (가방 휴대 방법이 보행 시 발바닥 접촉 양상에 미치는 영향)

  • Park, Soo-Jin;Kwon, Yoo-Jung;Kim, Min-Hee;Kim, Jin-Sang
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.2
    • /
    • pp.29-40
    • /
    • 2011
  • Purpose: The purpose of this study was to analyze the changes of parameters of foot contact by various carrying a pack methods during walking. Method: The subjects were consisted of normal forty four persons (males 30, females 14, mean age 23). The carrying a pack methods were classified into five conditions: carrying no bag(Con 1), carrying a backpack(Con 2), carrying a shoulder bag(Con 3), carrying a cross bag(Con 4), carrying a one-hand bag(Con 5). All subjects were participated in these five condition and measured foot pressure by F-scan system during walking. Then foot contact time, foot contact area, foot contact length and width were measured and analyzed. The repeated one-way analysis of variance (ANOVA) was used to get difference between conditions and independent t-test was used to get difference between left and right foot within condition. Result: In the comparison of parameters of foot, contact time, contact area and mid foot width were significantly different between conditions(p<.05), and in both foot contact time at condition 5 showed the most significant reduction(p<.05). In the comparison of parameters of foot between left and right foot within condition, every conditions were not significantly different(p>.05). Conclusion: In this study various carrying methods changed the parameters of foot contact and showed significant difference in some articles between carrying methods. However, asymmetric load of pack by carrying methods didn't affected symmetry of parameters of foot contact between left and right foot.

  • PDF

Immediate Effect of Fabric Ankle-Foot Orthosis on Spatiotemporal Gait Parameters in Children With Spastic Cerebral Palsy (패브릭 발목 보조기가 경직성 뇌성마비 아동의 시공간적 보행 변수에 미치는 즉각적인 효과)

  • Sim, Yon-Ju;Lee, Dong-Ryul;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.21 no.1
    • /
    • pp.29-36
    • /
    • 2014
  • The purpose of this study was to investigate the immediate effect of fabric ankle-foot orthosis on spatiotemporal gait parameters, compared to a barefoot condition in children with spastic cerebral palsy. Eleven children with spastic cerebral palsy participated in this study. Spatiotemporal gait parameters were measured with the GAITRite system. Fabric ankle-foot orthosis significantly improved Timed Up and Go test time and gait velocity. There was no significant difference in cadence. The step time significantly improved in both the more and less affected foot compared to the barefoot condition. The step length of the affected foot also significantly improved, but there was no significant difference in the step length of the less affected foot. There was significant improvement in the stride length of both the affected and less affected foot, but no significant difference in single stance or double stance. The fabric ankle-foot orthosis could improve stability, and selective control of the joint and promote better walking in children with cerebral palsy. Consequently, the fabric ankle-foot orthosis might be an alternative assistive device for neurological populations as a primary role instead of the typical ankle-foot orthosis.

The Effectiveness of the Use of Custom-Made Foot Orthotics on Temporal-Spatial Gait Parameters in Children With Spastic Cerebral Palsy

  • Kim, Sung-Gyung;Ryu, Young-Uk
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.16-23
    • /
    • 2012
  • This study examined the effects of custom-made foot orthotics on the temporal-spatial gait parameters in children with cerebral palsy. Twenty spastic bilateral cerebral palsy (spastic CP) children (11 boys and 9 girls) participated in this study. GAITRite was used to examine the velocity, cadence, step length differential, step length, stride length, stance time, single support time, double support time, base of support, and toe angle while walking with and without foot orthotics. The differences in temporal-spatial parameters were analyzed using paired t-test. The significance level was set at .05. The velocity, cadence, both step lengths, both stride lengths, both bases of support and right toe angle significantly increased when the children with spastic CP with foot orthotics compared to without foot orthotics (p<.05). The step length differential between the two extremities, left stance time and left single support time, significantly decreased with foot orthotics (p<.05). Right stance time, right single support time, both double support times and left toe angle showed little change (p>.05). This study demonstrated that foot orthotics were beneficial for children with spastic CP as a gait assistance tool.

A Study on Change in Gait Parameters Related to the Cop and Velocity Resulting from the Use of Ankle Foot Orthosis in Spastic Diplegia (경직성 양하지마비아의 발목 보조기 착용에 따른 체 중심및 보행속도에 의한 보행인자 변화연구)

  • Park, Mi-Sook;Kim, Yong-Seong;Hwang, Tae-Yeon;Kim, Yong-Nam
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • Purpose : The objectives of this study were to examine changes in gait parameters related to the COP and gait velocity resulting from the use of ankle foot orthosis, and to provide information for the prescription of ankle foot orthosis and gait rehabilitation training. Methods : We sampled a control group of 14 normal children of the same age as the spastic diplegia (spastic diplegia used ankle foot orthosis) and measured their COP at barefoot gait and their gait parameters at three gait velocities. Change in the COP according to the use of ankle foot orthosis measured one-way ANOVA and Gait parameters according to gait velocity used repeated measures ANOVA. Results : As a result of analyzing change in the COP it became close to that of normal children, and changes in gait parameters such as step width, stride length and stride time also became close to those of normal children. Conclusion : In conclusion, when spastic diplegia used ankle foot orthosis, their balancing ability was improved as a result of decreased change in the COP, and their changes in gait parameters also became close to those of the control group. These results show that the use of ankle foot orthosis improves spastic diplegia gait functions.

Change of Radiologic Index of Foot according to Radiation Projection Angle: A Study Using Phantom Foot (방사선 투과 각도에 따른 족부 방사선 지표의 변화: Phantom Foot을 이용한 연구)

  • Kim, Eo Jin;Seo, Sang Gyo;Lee, Dong Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.4
    • /
    • pp.165-170
    • /
    • 2015
  • Purpose: The purpose of this study is to analyze the measurement differences of simple radiographs according to radiation projection angle using a phantom and to propose methods for objective analysis of simple radiographs. Materials and Methods: We took simple radiographs with different projection angles using a C-arm image intensifier and measured five parameters of the foot on the simple radiographic images. Five parameters include lateral tibiocalcaneal angle, lateral talocalcaneal angle, naviculocuboid overlap, lateral talo-first metatarsal angle, and lateral calcaneo-first metatarsal angle. Intraobserver and interobserver reliability were verified, and then intraclass correlations of parameters were analyzed. Results: Radiographic parameters of the foot showed high intraobserver and interobserver reliability. Lateral tibiocalcaneal angle has a strong negative linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral talocalcaneal angle has a moderate positive linear relationship with rotation and a strong positive linear relationship with tilt. Naviculocuboid overlap has a strong positive linear relationship with rotation and a moderate positive linear relationship with tilt. Lateral talo-first metatarsal angle does not have a linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral calcaneo-first metatarsal angle has a moderate positive linear relationship with rotation and tilt. Conclusion: More precise evaluation of the foot with a simple radiograph can be performed by understanding the changes of radiographic parameters according to radiation projection angle.

The Relationship between Anthropometric Parameters of the Foot and Kinetic Variables during Running (달리기 시 발의 인체측정학적 변인과 운동역학적 변인의 관계)

  • Lee, Young Seong;Ryu, Jiseon
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.3
    • /
    • pp.173-183
    • /
    • 2019
  • Objective: The aim of this study was to investigate the correlation coefficients between anthropometric parameters of the foot and kinetic variables during running. Method: This study was conducted on 21 healthy young adults (age: $24.8{\pm}2.1yes$, height: $177.2{\pm}5.8cm$, body mass: $73.3{\pm}7.3kg$, foot length: $256.5{\pm}12.3mm$) with normal foot type and heel strike running. To measure the anthropometric parameters, radiographs were taken on the frontal and sagittal planes, and determined the length and width of each segment and the navicular height. Barefoot running was performed at a preferred velocity ($3.0{\pm}0.2m/s$) and a fixed velocity (4.0 m/s) on treadmill (Bertec, USA) in order to measure the kinetic variables. The vertical impact peak force, the vertical active peak force, the braking peak force, the propulsion peak force, the vertical force at mid-stance (vertical ground reaction when the foot is fully landed in mid-stance or at the point where the weight was uniformly distributed on the foot) and the impact loading rate were calculated. Pearson's correlation coefficient was used to investigate the relationship between anthropometric variables and kinetical variables. The significance level was set to ${\alpha}=.05$. Results: At the preferred velocity running, the runner with longer forefoot had lower active force (r=-.448, p=.041) than the runner with short forefoot. At the fixed velocity, as the navicular height increases, the vertical force at full landing moment increases (r= .671, p= .001) and as the rearfoot length increases, the impact loading rate decreases (r=- .469, p= .032). Conclusion: There was a statistically significant difference in the length of fore-foot and rearfoot, and navicular height. Therefore it was conclude that anthropometric properties need to be considered in the foot study. It was expected that the relationship between anthropometric parameters and kinetical variables of foot during running can be used as scientific criteria and data in various fields including performance, injury and equipment development.

Design of a Flexible Robot Foot with Toes and Heel Joints (발가락과 뒤꿈치 조인트를 갖는 유연한 로봇 발 설계)

  • Park, Jin-Hee;Kim, Hyun-Sul;Kwon, Sang-Joo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.446-454
    • /
    • 2011
  • In terms of the anatomy and mechanics of the human foot, a flexible robot foot with toes and heel joints is designed for a bipedal walking robot. We suggest three design considerations in determining foot design parameters which are critical for walking stability. Those include the position of the frontal toe, the stiffness of toes and heels, and the position of the ankle joint. Compared with the conventional foot with flat sale, the proposed foot is advantageous for human-like walking due to the inherent structural flexibility and the reasonable parameter values. Simulation results are provided to determine the design parameters and also show that the proposed foot enables smaller energy consumption.

The Height and Volume of Medial Longitudinal Arch in Normal and Painful Feet (정상인과 통증이 있는 족부의 내측 종아치의 높이와 부피)

  • Lee, Woo-Chun;Moon, Jeong-Seok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.8-12
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate the differences in simple radiographic parameters and results of 3-D scan among normal and patient groups. Materials and Methods: Seventy subjects in each group were studied. Control group consisted of subjects without plantar foot pain (normal group), and two patient groups were one with plantar forefoot pain (metatarsalgia group), the other with plantar heel pain (heel pain group). Simple radiographic parameters were obtained and 3-D scan was done with foot scanner (Nexscan, K&I, Korea) and The height and volumn of the space under the medial longitudinal arch was analyzed (Enfoot, K&I, Korea). These parameters were compared and correlation between radiological parameters and results of the 3-D scan were studied. Results: The results of all parameters istributed normally. There was no signigicant differences among the groups in radiological parameters (talo-first metatarsal angle, calcaneal pitch angle and height of the talar head in standing lateral radiograph) and arch height and arch volumn on 3-D scan. There were statistically significant correlations between radiological and 3-D scan results. Conclusion: This study revealed that there is no significant differences in medial longitudinal arch height and volumn among normal and different patient groups and there are variety of arch height in patients with similar symptoms.

  • PDF

Changes in the Plain Radiographic Parameters of the Forefoot with Heal Elevation - A Preliminary Report - (뒤꿈치 높임에 의한 전족부 단순 방사선 지표상의 변화 - 예비보고 -)

  • Lee, Woo-Chun;Jung, Hyun-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.4 no.2
    • /
    • pp.55-60
    • /
    • 2000
  • Purpose: To investigate the effect of heel elevation on the radiographic parameters of the forefoot. Materials and Methods: Forty feet in twenty-one adults were studied. Weight bearing dorsoplantar radiograph was taken with the foot on a flat surface and with the heel of the foot elevated by 5cm. Various parameters were measured and compared between the results with and without heel elevation. Result: The hallux valgus angle was increased by $5.0{\pm}3.5$ degrees with heel elevation and the change was statistically significant(p<0.01). There was no statistically significant changes in the other parameters. Conclusion: The results of this study suggest that high-heeled shoes might contribute in causing or aggravating the degrees of the hallux valgus.

  • PDF

Repeatability of a Multi-segment Foot Model with a 15-Marker Set in Normal Children

  • Kim, Eo Jin;Shin, Hyuk Soo;Lee, Jae Hee;Kyung, Min Gyu;Yoo, Hyo Jeong;Yoo, Won Joon;Lee, Dong Yeon
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.484-490
    • /
    • 2018
  • Background: The use of three-dimensional multi-segment foot models (3D MFMs) is increasing since they have superior ability to illustrate the effect of foot and ankle pathologies on intersegmental motion of the foot compared to single-segment foot model gait analysis. However, validation of the repeatability of the 3D MFMs is important for their clinical use. Although many MFMs have been validated in normal adults, research on MFM repeatability in children is lacking. The purpose of this study is to validate the intrasession, intersession, and interrater repeatability of an MFM with a 15-marker set (DuPont foot model) in healthy children. Methods: The study included 20 feet of 20 healthy children (10 boys and 10 girls). We divided the participants into two groups of 10 each. One group was tested by the same operator in each test (intersession analysis), while the other group was tested by a different operator in each test (interrater analysis). The multiple correlation coefficient (CMC) and intraclass correlation coefficient (ICC) were calculated to assess repeatability. The difference between the two sessions of each group was assessed at each time point of gait cycle. Results: The intrasession CMC and ICC values of all parameters showed excellent or very good repeatability. The intersession CMC of many parameters showed good or better repeatability. Interrater CMC and ICC values were generally lower for all parameters than intrasession and intersession. The mean gaps of all parameters were generally similar to those of the previous study. Conclusions: We demonstrated that 3D MFM using a 15-marker set had high intrasession, intersession, and interrater repeatability in the assessment of foot motion in healthy children but recommend some caution in interpreting the hindfoot parameters.