• 제목/요약/키워드: fuel leakage

검색결과 219건 처리시간 0.021초

누설특성을 고려한 GDI 엔진용 연료펌프의 고압생성 증진에 관한 연구 (A Study on the Pressure Increment of Fuel Pump for GDI Engines Considering Leakage Flows)

  • 나병철;김병수;최석우
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.785-791
    • /
    • 2000
  • GDI (Gasoline Direct Injection) engines are considered as one of the candidates for next generation engines of passenger cars, which reduce exhaust emissions and fuel consumption. In GOI engines, a high-pressure gasoline supply system is required to directly inject the fuel to combustion chambers. Because of low lubricity of gasoline fuel, the clearance between a plunger and a barrel in GDI fuel pumps is too wide to achieve smooth hydrodynamic lubrication. Thus, it is difficult to generate high-pressure condition in GDI fuel pump since large amount of leakage flow occurs between the plunger and the barrel In this study, an optimum plunger design is presented to minimize leakage in the aspect of flow control. This paper analyzes leakage flow characteristics in the clearance to improve pumping performance of GDI fuel pumps. Effects of groove in the plunger are studied according to variations of depth and width. Evaluations of pumping performance are determined by the amount of pressure drop in the leakage path assuming a constant leakage flows. Both of turbulence and incompressible models are introduced in CFD (Computational Fluid Dynamics) analysis. Design parameters have been introduced to minimize leakage in limited space, and a methodological study on geometrical optimization has been conducted. As results of CFD analysis in various geometrical cases, optimum groove depths have been found to generate maximum sealing effects on gasoline fuel between the plunger and the barrel. This procedure offers a methodological way of an enhancement of plunger design for high-pressure GDI fuel pumps.

연료전지자동차의 고압수소저장시스템 수소 누출 안전성 평가 (The Evaluation of Hydrogen Leakage Safety for the High Pressure Hydrogen System of Fuel Cell Vehicle)

  • 김형기;최영민;김상현;심지현;황인철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.316-322
    • /
    • 2012
  • A fuel cell vehicle has the hydrogen detection sensors for checking the hydrogen leakage because it use hydrogen for its fuel and can't use a odorant to protect the fuel cell stack. To verify the hydrogen safety of leakage we select the high possible leak points of fittings in hydrogen storage system and test the leaking behavior at them. The hydrogen leakage flow rate is 10, 40, 118 NL/min and the criterion for maximum hydrogen leakage is based on allowing an equivalent release of combustion energy as permitted by gasoline vehicles in FMVSS301. There are total 18EA hydrogen leakage detection sensors installed in test system. we acquire the hydrogen leakage detection time and determine the ranking. Hydrogen leakage detection time decrease when hydrogen leakage flow rate increase. The minimum hydrogen leakage detection time is about 3 seconds when the flow rate is 118NL/min. In this study, we optimize hydrogen sensor position in fuel cell vehicle and verify the hydrogen leakage safety because there is no inflow inside the vehicle.

가정용 연료전지 시스템 내부 수소 누출 시 센서 응답 특성에 관한 연구 (A experimental study on the sensor response at hydrogen leakage in a residential fuel cell system)

  • 김영두;신동훈;정태용;남진현;김영규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2009-2014
    • /
    • 2007
  • Hydrogen is a fuel of fuel cell system, which has powerful explosion possibility. Hence, the fuel cell system needs safety evaluation to prevent risk of hydrogen leakage. We use a actual size chamber of a common fuel cell module to analyze hydrogen. Hydrogen injection holes are located in lower part of the chamber in order to simulated hydrogen leakage. The hydrogen sensor can detect range of 0${\sim}$4%. Since the hydrogen gas, of which leaked amount is controled by MFC, are injected at the bottom holes, the transient sensor signals are measured. At a condition of 10cc/s of hydrogen leakage, the sensor detects hydrogen leakage after 22sec and there is also several seconds of time delay depending on the position of the sensor. This experimental data can be applied for the design of the hydrogen detection system and ventilation system of a residential fuel cell system.

  • PDF

LPG연료품질에 따른 LPG액상분사방식의 내구특성연구 (Durability Properties of Liquid Phase LPG Injection System with Various Qualities of LPG Fuels)

  • 김창업;오승묵;강건용
    • 한국자동차공학회논문집
    • /
    • 제12권5호
    • /
    • pp.73-78
    • /
    • 2004
  • The liquid phase LPG injection (LPLi) system (the third generation technology) has been considered as one of the next generation fuel supply systems for LPG vehicles, since it has a very strong potential to accomplish the higher power, higher efficiency, and lower emission characteristics than the mixer type(the second generation technology) fuel supply system. To investigate the durability property of core part of injector in liquid phase LPG injection system, leakage test, SEM test of injectors and analysis of unvaporized fuel components with various LPG fuel qualities were tested. The experimental results showed that no serious problem in durability test using favorable LPG fuel quality, while high leakage amount due to the large scratches in the needle and nozzle of the injector were found using LPG fuel with highly containing olefin components, especially butadiene species.

가정용 연료전지 시스템 내부 수소 누출 시 센서 응답 특성에 관한 연구 (An Experimental Study on the Sensor Response at Hydrogen Leakage in a Residential Fuel Cell System)

  • 김영두;신동훈;정태용;남진현;김영규;이정운
    • 한국수소및신에너지학회논문집
    • /
    • 제20권5호
    • /
    • pp.378-383
    • /
    • 2009
  • Hydrogen is the primary fuel in fuel cell systems. Because of high inflammation and explosion possibility of hydrogen, fuel cell systems require safety measures to prevent hydrogen hazard upon leakage. In this study, a model enclosure was made by referring to a commercial residential fuel cell system and hydrogen leakage experiments and computational simulations were conducted therein. Hydrogen was injected into the cavity through leakage holes located at the bottom while its flow rate was precisely controlled using MFC. The transient sensor signals from hydrogen sensors installed inside the enclosure were recorded and analyzed. The hydrogen sensor signals showed different delay times depending on their position relative to a leakage point, which indicated that hydrogen generally moves upward and accumulates at the upper region of a closed cavity. The inflammable regions with hydrogen concentration over 4% LEL were observed to locate near the leakage hole initially, and broaden towards the upper cavity region afterward. The simulation result showed that detection time at the hydrogen sensor was similar to the pattern of experimental results. However, the maximum concentration of hydrogen had a gap between experiment and simulation at detect point due to measurement errors and reaction rate.

ISO 12807에 따른 사용후핵연료 및 금속전환체의 허용 누설률 (Allowable Leakage Rate of Spent Fuel and Conditioned Spent Fuel in compliance with ISO 12807)

  • 방경식;이주찬;주준식;서기석;김호동
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.609-613
    • /
    • 2003
  • 사용후핵연료 및 방사성물질을 저장하기 위한 저장시스템은 사용후핵연료를 저장하는 동안 안전성 문제를 야기하지 않도록 격납을 설계하고 평가하여야 하며, 격납 평가는 ANSI Nl4.5 또는 ISO 12807에서 규정하고 있는 절차에 따른 허용 누설률을 계산하여 평가할 수 있다. 따라서, ISO 12807에서 규정한 평가방법에 따라 PWR 사용후핵연료 24 다발을 저장하였을 경우와 금속전환체 24다발을 저장하였을 경우에 대한 허용 누설률을 평가하였다. OWR 사용후핵연료 24다발을 저장하였을 경우 허용 누설률은 $1.38{\times}10_{-10}m_3/s$로, 금속전환체 24다발을 저장하였을 경우 $4.46{\times}10_{-10}m_3/s$로 평가되었다. 따라서, 사용후핵연료를 저장하였을 경우보다 금속전환체를 저장하였을 경우 격납 조건이 수월해 짐을 알 수 있었다.

  • PDF

저점도 LPG연료 인젝터의 누설특성에 관한 연구 (Leakage Characteristics of LPG injector with Low Viscosity LPG Fuel)

  • 김창업;박철웅;오승묵;강건용
    • 한국분무공학회지
    • /
    • 제10권4호
    • /
    • pp.8-15
    • /
    • 2005
  • The use of clean gaseous fuels for the purpose of high efficiency and low emission in automotive engines has tendency to increase in order to meet the reinforcing emission regulations and to efficiently utilize limited natural resources. Automotive companies developed and commercialized a LPG liquid injection system, which is mounted on LPLi(Liquid Phase LPG Injection) engines and vehicles based on this research trend. This research examines the biggest problem in LPLi engine, that is, the leakage characteristics of low viscosity LPG fuel according to the injector design variables. This study is also aimed to improve the performance of fuel-leakage in LPLi engine through the addition of a lubrication improver in HFRR(High Frequency Reciprocating Rig) facility. The needle displacement and the spring displacement of an LPLi injector are found to be already optimized. The possibility of a maximum of 70% leakage reduction compared to a conventional case, is verified when 1000ppm of a lubrication improvement material is added and 40% increase of a injector spring constant (K) is applied.

  • PDF

주행 데이터 분석을 통한 수소버스 운행안전 모니터링 기법 연구 (Study of Hydrogen Bus Operational Safety Monitoring Method through Driving Data Analysis)

  • 이현미;이인식;이용주;장정아;김시우; 심소정
    • 자동차안전학회지
    • /
    • 제15권4호
    • /
    • pp.58-64
    • /
    • 2023
  • The adoption of hydrogen-powered Elec is expanding globally. Hydrogen is recognized as a potentially hazardous energy source, and safety assessment is crucial for the development of plans to supply hydrogen-powered electric buses. Hydrogen gas leakage can have a significant impact during bus operations, and continuous hydrogen leakage in hydrogen-powered vehicles can result in fatal accidents. In this study, information about hydrogen leakage is collected through sensors installed within the vehicles and is measured when the sensor detects a leak. The study also proposes the use of Pseudo Fuel Leakage (PFL, %) as an additional indicator for evaluating and monitoring hydrogen safety and leakage.

가속노화조건 하 연료접촉 고무오링의 수명예측 및 누유시험 연구 (A Study on the Lifetime Estimation and Leakage Test of Rubber O-ring in Contacted with Fuel at Accelerated Thermal Aging Conditions)

  • 정근우;홍진숙;김영운;한정식;정병훈;권영일
    • Tribology and Lubricants
    • /
    • 제35권4호
    • /
    • pp.222-228
    • /
    • 2019
  • As rubber products such as O-rings, which are also known as packings or toric joints, come in regular, long term contact with liquid fuel, they can eventually swell, become mechanically weakened, and occasionally crack; this diminishes both their usefulness and intrinsic lifetime and could cause leaks during the steady-state flow condition of the fuel. In this study, we evaluate the lifetime of such products through compression set tests of FKM, a family of fluorocarbon elastomer materials defined by the ASTM international standard D141; these materials have great compression, sunlight, and ozone resistance as well as a low gas absorption rate. In this process, O-rings are immersed in the liquid fuel of airtight containers that can be expressed as a compression set, and the liquid fuel leakage in a flow rig tester at variable temperatures over 12 months is investigated. Using the Power Law model, our study determined a theoretical O-ring lifetime of 2,647 years, i.e. a semi-permanent lifespan, by confirming the absence of liquid fuel leakage around the O-ring assembled fittings. These results indicate that the FKM O-rings are significantly compatible for fuel tests to evaluate long-term sealing conditions.

자동차 연료 시스템에관한 연료 응고, 누설, 불량 휘발유 및 연료 첨가제에 의한 고장 사례 고찰 (Study of Failure Examples for Fuel Coagulation, Leakage, Low Grade Gasoline and Fuel Additives in Automotive Fuel System)

  • 이일권;김영규;고영배;김승철
    • Tribology and Lubricants
    • /
    • 제28권4호
    • /
    • pp.178-183
    • /
    • 2012
  • The fuel system of a vehicle is a very important compotent, as it provides the firing resources to the combustion chamber of the engine. However, improper operation of the system can generate bad condition or start-off during engine revolution. This study analyzed several examples of failure that had originated in the field. In the first example, the driver operated a vehicle containing both gasoline and LPG in the fuel tank, but the gasoline fuel remained unused for a few months. Therefore the fuel pump was clogged because of gasoline congelation. The second example, dealt with fuel leakage that occurred from the slightly torn O-ring connecting the fuel lines. The third example, pertained to engine damage and power-down owing to the usage of proor-quality fuel and ingredient. Therefore, it is necessary to take adequate measures to prevent the failure of the fuel system of vehicle.