• Title/Summary/Keyword: gas permeation

Search Result 381, Processing Time 0.025 seconds

Gas Permeation Characteristics of Porous Alumina Membrane Prepared by Anodic Oxidation (양극산화에 의한 다공성 알루미나 막의 기체투과 특성)

  • 함영민
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.3
    • /
    • pp.72-78
    • /
    • 1998
  • For investigation into gas permeation characteristics, the porous alumina membrane with asymmetrical structure, having upper layer with 10 nanometer under of pore diameter and lower layer with 36 nanometer of pore diameter, was prepared by anodic oxidation using DC power supply of constant current mode in an aqueous solution of sulfuric acid. The aluminium plate was pre-treated with thermal oxidation, chemical polishing and electrochemical polishing before anodic oxidation. Because the pore size depended upon the electrolyte, electrolyte concentration, temperature, current density, and so on, the the membranes were prepared by controling the current density, as a very low current density for upper layer of membrane and a high current density for lower layer of membrane. By control of current quantity, the thicknesses of upper layer of membranes were about $6{\;}{\mu}m$ and the total thicknesses of membranes were about $80-90{\;}{\mu}m$. We found that the mechanism of gas permeation depended on model of the Knudsen flow for the membrane prepared at each condition.

  • PDF

Preparation, Characterization, and Gas Permeation Properties of Carbon Molecular Sieve Membranes Derived from Dense P84-Polyimide Film

  • Park, Ho-Bum;Nam, Sang-Yong;Jang, Jeong-Gyu;Lee, Young-Moo
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.25-35
    • /
    • 2002
  • The gas permeation properties have been studied on carbon molecular sieve (CMS) membranes prepared by pyrolysis of P84 polyimide under various conditions. P84 polyimide shows high permselectivities (O$_2$/N$_2$= 9.17 and CO$_2$/N$_2$= 35) for various gas pairs and has a good processibility because it is easily soluble in high polar solvents such as N-methylpyrrolidinone (NMP), dimethylformamide (DMF), and N,N-dimethylacetamide (DMAc). After pyrolysis under Ar flow, the change in the heating rate was found to affect the gas permeation properties to some extent. The permeabilities of the selected gases were shown to be in the order He > CO$_2$> O$_2$> N$_2$for all the CMS membranes, whose order was in accordance with the order of kinetic gas diameters. It also revealed that the pyrolysis temperature considerably influenced the gas permeation properties of the CMS membranes derived from P84 polyimide. The CMS membranes pyrolized at 700$\^{C}$ temperature exhibited the highest permeability with relatively targe loss in permselectivity. This means that the pyrolysis temperature should be varied in accordance with target gases to be separated.

A study of model for nitrogen permeation in TIG welding of super duplex stainless steel (슈퍼듀플렉스 스테인리스강의 TIG 용접에서 질소 침투 모델에 관한 연구)

  • Lee, Jae-Hyoung;Jung, Byong-Ho;Cho, Sang-Myung;Jun, Jae-Ho
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.68-74
    • /
    • 2015
  • Superduplex stainless steels are important materials to the oil and gas industry, especially for off-shore production. TIG welding of super duplex stainless steels to obtain the optimal phase balance between austenite and ferrite is mainly achieved by controlling the cooling rate and the weld chemistry. The latter depends on the filler wire chosen and the shielding gas used. If TIG welding of superduplex stainless steels is performed with argon shielding gas only, then nitrogen gets lost from the weld pool, which can result in a ferrite-rich weld metal, with an inferior corrosion resistance than parent metal. In the present study, nitrogen permeation model from the shield gas which gets into the weld metal in DCEN-TIG welding has suggested. This plasma stream model shows characteristics of permeation of nitrogen ions into the molten metal due to the strong physical effect of plasma stream which formed by the arc pressure rather than the permeation of nitrogen ions caused by electric effect.

Performance Test of Silicone Rubber Membrane by Gas Permeation Method (기체투과에 의한 Silicone Rubber Membrane의 기능성 시험)

  • Lee, Seung-Bum;Hong, In-Kwan
    • Elastomers and Composites
    • /
    • v.33 no.1
    • /
    • pp.37-43
    • /
    • 1998
  • The permeation of gas through polymer membrane at temperatures above its glass transition, generally occurs by a solution-diffusion mechanism. This mechanism is performed by the affinity difference between polymeric materials and gas molecules, and various technologies, such as copolymerization, impregnation and so on, have been researched to improve the affinity of polymeric material for the gases. In this study, permeability and selectivity for some gases were obtained from steady-state rates of gas permeation through silicone rubber membrane which is prepared by supercritical fluid extraction method. The permeability was measured by the volumetric method proposed by Barrer. Permeability was increased generally with temperature and permeation pressure. Silicone rubber membrane shows a higher permeability to $CO_2$ than to $O_2$, $N_2$. This results probably reflect the relatively high solubility of CO_2 in silicone rubber membrane, which is due to the affinity of $CO_2$ molecules. Since separation powers of $CO_2/N_2$, $CO_2/O_2$ were more than 200, and 100, respectively, it is able to separate $CO_2$ from the air, and the optimum temperature and pres-sure was 328.15 K, 60 cmHg respectively. In future, it is possible that the silicone rubber membrane can be used for separation or concentration of $CO_2$ through experiment for mixed gas separation.

  • PDF

Evaluation of Gas Transport Parameters through Dense Polymeric Membranes by Continuous-Flow Technique (연속흐름방식에 의한 기체투과특성 측정 및 분석)

  • 염충균;이정민;홍영택;김성철
    • Membrane Journal
    • /
    • v.9 no.3
    • /
    • pp.141-150
    • /
    • 1999
  • A novel permeation apparatus was developed which could make the on-line measurements of both flux transient and permeate composition in gas permeation. The measurement by using the per¬meation apparatus was based on the continuous-flow technique. The transient measurement allowed the simultaneous determinations of permeation characteristics, such as, permeability, diffusion and solubility coefficients, and activation energies only with one experiment. The apparatus performance was illustrated by conducting the permeation of pure gases through two glassy polyimides and a rubbery poly (dimethyl¬siloxane) membranes, respectively. A comparison of the permeation characteristics determined from the flux transients was made with the literature values for verifying the confidence and accuracy of the measurement. Also, the analysis of the permeation transients obtained was carried out for the close investigation of the permeation behaviors of gases through membrane.

  • PDF

Development of Adsorptive Permeation Membrane (APM) and Process for Separation of $CO_2$ from gas mixtures (이산화탄소 분리를 위한 흡착투과막 및 공정 개발)

  • Yeom, Choong Kyun;Ahn, Hyo Sung;Kang, Kyeong Rok;Kim, Joo Yul;Han, Jin-Soo;Kwon, Keun-Oh
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.409-417
    • /
    • 2013
  • Adsorptive permeation hollow fiber membrane (APM) has been developed for effectively separating $CO_2$ from gas mixture. Inside the APM, zeolite 13X particles were uniformly dispersed without covering their surfaces by a symmetric porous structure of polypropylene lattice. In this study, $CO_2/N_2$ mixture was used as a simulated gas mixture. Separation was achieved by adsorbing $CO_2$ on the zeolite particles in the APM and then permeating $N_2$ into permeate side in passing all the feed gas through the APM. Adsorptive permeation tests were carried out with a set of APM modules, and the adsorptive permeation performances of the modules were analyzed from the test results. After saturation of the adsorbent with $CO_2$, the APM was regenerated by desorption of $CO_2$ from it through vacuuming both inside of outside of the APM hollow fiber, and the regeneration process of the APM by vacuuming was discussed in terms of regeneration efficiency and energy consumption.

Effects of CO and $CO_2$ on Hydrogen Permeation through Pd-coated V-Ti-Ni Alloy Membranes (Pd 코팅된 V-Ti-Ni 합금 분리막을 통한 수소투과에서 CO와 $CO_2$의 영향)

  • Jeon, Sung-Il;Park, Jung-Hoon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.21 no.3
    • /
    • pp.290-298
    • /
    • 2011
  • The influence of co-existing gases on the hydrogen permeation was studied through a Pd-coated $V_{53}Ti_{26}Ni_{21}$ alloy membrane. The hydrogen permeation characteristics of Pd-coated $V_{53}Ti_{26}Ni_{21}$ alloy membrane have been investigated in the pressure range 1-3 bar under pure hydrogen and hydrogen mixture gas with carbon dioxide and carbon monoxide at $450^{\circ}C$. Preliminary hydrogen permeation experiments have been confirmed that hydrogen flux was $5.36mL/min/cm^2$ for a Pd-coated $V_{53}Ti_{26}Ni_{21}$ alloy membrane (thick: 0.5 mm) using pure hydrogen as the feed gas. In addition, hydrogen fluxes were 4.46, 5.20, $3.91mL /min/cm^2$ for$V_{53}Ti_{26}Ni_{21}$ alloy membrane using $H_2/CO_2$, $H_2/CO$ and $H_2/CO_2/CO$ as the feed gas respectively. Therefore, the hydrogen permeation flux decreased with decrease of hydrogen partial pressure irrespective of temperature and pressure when $H_2/CO_2$, $H_2/CO$ and $H_2/CO_2/CO$ mixture applied as feed gas respectively and permeation fluxes were satisfied with Sievert's law in different feed conditions. It was found from XRD results after permeation test that the Pd-coated $V_{53}Ti_{26}Ni_{21}$ alloy membrane had good stability and durability for various mixtures feeding condition.

Preparation of Nanoporous Ceramic Membranes by Sol-gel Method and Characterization of Gas Permeation (졸-겔법에 의한 나노기공성 세라믹 막의 제조 및 기체투과 특성)

  • Lee, Yong-Taek;Choi, Ga-Young;Han, Hyuk-Hee
    • Membrane Journal
    • /
    • v.18 no.2
    • /
    • pp.176-184
    • /
    • 2008
  • Nano-porous ceramic membranes was synthesized by the sol-gel method. Gas permeation of hydrogen and nitrogen was determined by single composition gas. Pore size $0.1{\mu}m$ and porosity 32% of flat type ${\alpha}-Al_2O_3$ substrate was manufactured. An intermediate ${\gamma}-Al_2O_3$ layer with pore size of 4 nm was formed by dip-coating. Polymeric silica sol was synthesized by acid catalyzed hydrolysis and condensation of tetra-ethyl-ortho-silicate. Supported membranes on alumina were prepared by dipping and calcining. He, $N_2$ permeation experiments with nanoporous sol-gel modified supported ceramic membranes were peformed to determine the gas transport characteristics. $He/N_2$ permselectivity around $100{\sim}160$ and helium permeation in the order of $10^{-7}mol/m^2{\cdot}s{\cdot}Pa$ were measured in the temperature range of $303{\sim}363K$.

Hydrogen separation of $V_{99.8}B_{0.2}$ Alloy Membrane in Water-gas shift Reaction (수성 가스 전이반응에서 $V_{99.8}B_{0.2}$ 합금 분리막의 수소분리)

  • Jeon, Sung-Il;Jung, Yeong-Min;Park, Jung-Hoon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • The influence of co-existing gases on the hydrogen permeation without sweep gas was studied through a Pd-coated $V_{99.8}B_{0.2}$ alloy membrane. Membranes have been investigated in the pressure range 1.5-8.0 bar under pure hydrogen, hydrogen-carbon dioxide and hydrogen-carbon monoxide gas mixture without sweep gas at $400^{\circ}C$. Preliminary hydrogen permeation experiments without sweep gas have been confirmed that hydrogen flux was $40.7mL/min/cm^2$ for a Pd-coated $V_{99.8}B_{0.2}$ alloy membrane (thick : 0.5 mm) using pure hydrogen as the feed gas. In addition, hydrogen flux was $21.4mL/min/cm^2$ for $V_{99.8}B_{0.2}$ alloy membrane using $H_2/CO_2$ as the feed gas. The hydrogen permeation flux decreased with decrease of hydrogen partial pressure irrespective of pressure when $H_2/CO_2$and $H_2/CO$mixture applied as feed gas respectively and permeation fluxes were satisfied with Sievert's law in different feed conditions. It was found from XRD, SEM/EDX results after permeation test that the Pd-coated $V_{99.8}B_{0.2}$ alloy membrane had good stability and durability for various mixtures feeding condition.

Gas Permeation Properties of Hydroxyl-Group Containing Polyimide Membranes

  • Jung, Chul-Ho;Lee, Young-Moo
    • Macromolecular Research
    • /
    • v.16 no.6
    • /
    • pp.555-560
    • /
    • 2008
  • A series of hydroxyl-group containing polyimides (HPIs) were prepared in order to investigate the structure-gas permeation property relationship. Each polymer membrane had structural characteristics that varied according to the dianhydride monomers. The imidization processes were monitored using spectroscopic and thermog-ravimetric analyses. The single gas permeability of He, $H_2$, $CO_2$, $O_2$, $N_2$ and $CH_4$ were measured and compared in order to determine the effect of the polymer structure and functional -OH groups on the gas transport properties. Surprisingly, the ideal selectivity of $CO_2/CH_4$ and $H_2/CH_4$ increased with increasing level of -OH incorporation, which affected the diffusion of $H_2$ or the solubility of $CO_2$ in HPIs. For $H_2/CH_4$ separation, the difference in the diffusion coefficients of $H_2$ and $CH_4$ was the main factor for improving the performance without showing any changes in the solubility coefficients. However, the solubility coefficient of $CO_2$ in the HPIs increased at least four fold compared with the conventional polyimide membranes depending on the polymer structures. Based on these results, the polymer membranes modified with -OH groups in the polymer backbone showed favorable gas permeation and separation performance.