• 제목/요약/키워드: glass fiber

검색결과 1,681건 처리시간 0.036초

수종의 실란처리 유리섬유를 첨가한 의치상용 레진의 강도변화 및 마모전.후 표면성상분석 (EFFECTS Of VARIOUS SILANE COUPLING AGENTS ON THE STRENGTH AND THE SURFACE ROUGHNESS OF GLASS FIBER-ADDED PMMA RESIN)

  • 이상일;김창회;임영준;김명주;윤석대
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.457-468
    • /
    • 2007
  • Statements of problem: The fracture of acrylic resin dentures remains an unsolved problem. Therefore, many investigations have been performed and various approaches to strengthening acrylic resin, for example, the reinforcement of heat-cured acrylic resin using glass fibers, have been suggested over the years. Silane is important for bonding between glass fiber and resin. Purpose: The aim of the present study was to investigate the effect of various silane on the strength of PMMA resin and roughness of resin-glass fiber complex after abrasion test. Material and methods: 3mm glass fiber (Chopped strand, Hankuk fiber Co., Milyang, Korea) was treated with 3 kinds of silane (MPS, EPS, APS) (Sila-ace, Chisso chemical, Tokyo, Japan) and mixed with PMMA resin(Vertex RS, Vertex Dental B.V., Zeist, Netherlands). Transverse strength and Young's modulus was measured using Instron (Instron model 4466, Instron, Massachusetts, USA). After abrasion test (The 858 Mini Bionix II Test System, MTS System Co., Minnesota, USA) surface roughness was evaluated using tester (Form Talysurf plus, Taylor Hopson Ltd., Leicester England). Examination of scanning electron microscope was also performed. Results: Within this study, the following conclusions were drawn. 1. Surface treatment of glass fiber with MPS and APS increased transverse strength of PMMA resin complex, but surface treatment with EPS decreased transverse strength of PMMA resin complex (p<0.05). 2. Silane treated glass fiber increased Young's modulus of PMMA resin complex compared to desized glass fiber (p<0.05). 3. Roughness increased after abrasion test in case of PMMA resin reinforced with desized glass fiber (p<0.05). 4. Roughness change was not observed after abrasion test in case of PMMA resin reinforced with silane treated glass fiber (p>0.05).

EFFECTS OF CHOPPED GLASS FIBER ON THE STRENGTH OF HEAT-CURED PMMA RESIN

  • Lee Sang-Il;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.589-598
    • /
    • 2001
  • The fracture of acrylic resin dentures remains an unsolved problem. Therefore, many investigations have been performed and various approaches to strengthening acrylic resin, for example, the reinforcement of heat-cured PMMA resin using glass fibers, have been suggested over the years. The aim of the present study was to investigate the effect of short glass fibers treated with silane coupling agent on the transverse strength of heat-polymerized PMMA denture base resin. To avoid fiber bunching and achieve even fiber distribution, glass fiber bundles were mixed with PMMA powder in conventional mixer whose blade was modified to be blunt. Composite of glass fiber($11{\mu}m$ diameter, 3mm & 6mm length, silane treated) and PMMA resin was made. Transverse strength and Young's modulus were estimated. Glass fibers were incorporated with 1%, 3%, 6% and 9% by weight. Plasticity and workability of dough was evaluated. Fracture surface of specimens was investigated by SEM. The results of this study were as follows 1. 6% and 9% incorporation of 3mm glass fibers in the PMMA resin enhanced the transverse strength of the test specimens(p<0.05). 2. 6% incorporation of 6mm glass fibers in the PMMA resin increased transverse strength, but 9% incorporation of it decreased transverse strength(p<0.05). 3. When more than 3% of 3mm glass fibers and more than 6% of 6mm glass fibers were incorporated, Young's modulus increased significantly(p<0.05). 4. Workability decreased gradually as the percentage of the fibers increased. 5. Workability decreased gradually as the length of the fibers increased. 6. In SEM and LM, there was no bunching of fibers and no shortening of fibers.

  • PDF

직물유리섬유 강화집성재의 물리적 특성(제1보) - 기계적 특성 - (Physical Properties of Fabric E-glass Fiber Reinforced Laminated Timber (I) - Mechanical Properties -)

  • 정인석;이원희;변희섭
    • Journal of the Korean Wood Science and Technology
    • /
    • 제31권5호
    • /
    • pp.23-34
    • /
    • 2003
  • 본 연구는 국산소경재인 소나무(Pinus densiflora)재와 낙엽송(Larix kaemferi)재로 제조된 유리섬유강화 집성재의 강도적 성질을 조사해 보기 위하여 실시되었다. 먼저, 직물 유리섬유를 수성고분자-이소시아네이트계(MPU-500) 접착제를 사용하여 control재와 유리섬유를 각각 1층과 2층 함입하였다. 본 연구의 결과는 다음과 같다. 1. 수성고분자-이소시아네이트 수지는 집성재 제조용으로 적합하였으며, 특히 유리섬유를 2층 함입한 소재를 제외하고는 구조용 집성재의 품질기준(KS F 3021)을 만족시켰다. 2. 직물유리섬유를 함입할 경우 휨강도, 전단강도에서 control재보다 크게 뛰어나지는 않았지만, 비례한도 휨응력은 유리섬유의 함입 층수에 비례하여 증가하였다. 그러므로, 직물 유리섬유의 mesh수와 두께를 집성재 소재의 형태에 따라 적절히 조정한다면, 휨강도와 전단강도를 좀더 향상시킬 수 있을 것으로 판단되었다.

화재시 횡구속재 변화에 따른 고성능 콘크리트의 폭열방지성능에 관한 기초적 연구 (A Fundamental Study on the Performance of Spalling Resistance of High Performance Concrete with Material of Lateral Confinement Subjected to Fire)

  • 배정렬;황인성;홍상희;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.47-50
    • /
    • 2002
  • This paper presents the results of fire resistance properties of high performance concrete varying with fiber kinds and the size of metal lath in order to verify the validities of fiber on the spatting resistance by fire. Metal lath, glass fiber and carbon fiber are used to confine the concrete. According to test results, plain concrete without lateral confinement and confined concrete with glass fiber and carbon fiber show entire failure after exposed to fire, while confined concrete with metal lath take place in the form of slight surface spatting by fire, which has favorable spatting resistance of concrete. As for the effect of the size of metal lath, when the size of metal lath is more than 1.2mm of thickness, the residual strength of concrete exposed to fire maintains more than 80% of its original strength. However, glass fiber and carbon fiber does not perform desirable spatting resistance by fire due to loss of lateral confinement of fiber exposed to fire caused by melting of fiber and reducing bond strength between concrete and fiber.

  • PDF

Fracture behavior of monotype and hybrid fiber reinforced self-compacting concrete at different temperatures

  • Mazloom, Moosa;Karimpanah, Hemin;Karamloo, Mohammad
    • Advances in concrete construction
    • /
    • 제9권4호
    • /
    • pp.375-386
    • /
    • 2020
  • In the present study, the effect of basalt, glass, and hybrid glass-basalt fibers on mechanical properties and fracture behavior of self-compacting concrete (SCC) mixes have been assessed at room and elevated temperatures. To do so, twelve mix compositions have been prepared such that the proper workability, flowability, and passing ability have been achieved. Besides, to make comparison possible, water to binder ratio and the amount of solid contents were kept constant. Four fiber dosages of 0.5, 1, 1.5, and 2% (by concrete volume) were considered for monotype fiber reinforced mixes, while the total amount of fiber were kept 1% for hybrid fiber reinforced mixes. Three different portions of glass and basalt fiber were considered for hybridization of fibers to show the best cocktail for hybrid basalt-glass fiber. Test results indicated that the fracture energy of mix is highly dependent on both fiber dosage and temperature. Moreover, the hybrid fiber reinforced mixes showed the highest fracture energies in comparison with monotype fiber reinforced specimens with 1% fiber volume fraction. In general, hybridization has played a leading role in the improvement of mechanical properties and fracture behavior of mixes, while compared to monotype fiber reinforced specimens, hybridization has led to lower amounts of compressive strength.

횡구속 재료변화에 따른 고성능 콘크리트의 역학적 특성에 관한 실험적 연구 (An Experimental Study on the Mechanical Properties of High Performance Concrete with Material for Lateral Confinement)

  • 김은호;정덕우;홍상희;윤기원;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.563-568
    • /
    • 2002
  • This paper is a fundamental study on the mechanical properties of the high performance concrete confined with metal lath, glass and carbon fiber laterally. According to the results, it shows that the compressive strength increases by 9%, 8% and 6% in metal lath carbon fiber and glass fiber in case of W/B 30% respectively. In case of W/B 30% and 40%, flecxural strength shows largely in order of carbon fiber, metal lath, glass fiber. In strain-stress curve with the kinds of material for lateral confinement, while brittleness failure occurs in plain concrete just after maximum load, it is improved in some degree in confined concrete due to increase of the strain by increase of toughness. But, elastic modulus shows the similar tendency between confined concrete and plain concrete. Length change ratio by drying shrinkage shows little a bit in order of carbon fiber, glass fiber and metal lath due to confinement.

  • PDF

Damage Monitoring of CP-GFRP/GFRP Composites by Measuring Electrical Resistance

  • Shin, Soon-Gi;Kwon, Yong-Jung
    • 한국재료학회지
    • /
    • 제20권3호
    • /
    • pp.148-154
    • /
    • 2010
  • It is necessary to develop new methods to prevent catastrophic failure of structural material in order to avoid accidents and conserve natural and energy resources. Design of intelligent materials with a self-diagnosing function to prevent fatal fracture of structural materials was achieved by smart composites consisting of carbon fiber tows or carbon powders with a small value of ultimate elongation and glass fiber tows with a large value of ultimate elongation. The changes in electrical resistance of CF-GFRP/GFRP (carbon fiber and glass fiber-reinforced plastics/glass fiber-reinforced plastics) composites increased abruptly with increasing strain, and a tremendous change was seen at the transition point where carbon fiber tows were broken. Therefore, the composites were not to monitor damage from the early stage. On the other hand, the change in electrical resistance of CP-GFRP/GFRP (carbon powder dispersed in glass fiber-reinforced plastics/glass fiber-reinforced plastics) composites increased almost linearly in proportion to strain. CP-GFRP/GFRP composites are superior to CF-GFRP/GFRP composites in terms of their capability to monitor damage by measuring change in electrical resistance from the early stage of damage. However, the former was inferior to the latter as an application because of the difficulties of mass production and high cost. A method based on monitoring damage by measuring changes in the electrical resistance of structural materials is promising for improved reliability of the material.

유리섬유 강화 근관치료 포스트의 제조 및 특성에 대한 연구 (Preparation and properties of glass fiber-reinforced endodontic (root canal therapy) posts)

  • 손재용;김경자;김경훈;박주석;심광보
    • 한국결정성장학회지
    • /
    • 제25권3호
    • /
    • pp.105-110
    • /
    • 2015
  • 근관 치료를 위해 사용되는 섬유 강화형 포스트를 광중합 레진과 유리섬유를 이용하여 제조하였다. 제조된 포스트는 유리 섬유의 밀도가 높아짐에 따라 기계적 특성이 향상됨을 확인 할 수 있었고 광중합 레진의 점도 조절 및 진공함침 공정을 통해 미세 기공을 효과적으로 제거 할 수 있었다. 유리섬유와 광중합 레진과의 계면 결합력을 향상시키기 위해 유리 섬유 표면을 실란 커플링제를 사용하여 표면처리를 하였으며, 유리섬유의 표면처리는 유리 섬유 표면에 레진의 젖음성을 향상시켜 레진과의 결합 특성을 향상시키고 포스트의 기계적 특성을 향상시킴을 확인할 수 있었다.

진공단열재의 단열성능을 개선을 위한 Glass Fiber 수평 배열(다층구조) 기술 개발

  • 한정필;황승석;전승민;민병훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.207-207
    • /
    • 2012
  • 진공단열재는 폴리우레탄 폼 대비 10배 이상의 단열성능을 갖는 고효율 단열재로서 고차단성 필름 봉투 내부에 무기 소재를 진공감압시켜 대류에 의한 열전달을 최소화시킨 차세대 단열재이다. 특히 진공단열재에 있어 열전달의 경로는 전도에 의한 효과가 가장 크므로, 진공단열재 내부의 Glass Fiber 심재의 최적화 설계에 따라 단열 성능을 극대화 시킬 수 있다. 이에, 본 연구에서 GLass Fiber의 배열에 따른 성능 비교 평가를 통해, 전도의 특성을 최소화 시킬 수 있는 Glass Fiber의 배열 및 다층 적층 구조를 통해 성능 개선 효과를 고찰 하였다.

  • PDF

GFRP 보강 폴리머 모르터 3중복합관의 구조적 특성 (Structural Evaluation of Glass-fiber Reinforced 3-Layer Polymer Composite Pipe)

  • 연규석;권윤환;유근우;김남길
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.147-151
    • /
    • 2001
  • This study was performed to evaluate the internal and external factors affecting external strength of the 3-layer polymer composite pipes made of polymer mortar and fiber-glass reinforced plastic. Twenty four sandwich type 3-layer polymer composite pipes were made of polymer mortar and fiber-glass reinforced plastic by centrifugal method. The objective of this study was to evaluate the effects the of polymer mortar thickness for and core fiber-glass contents per unit area on external strength of 3-layer polymer composite pipes. For the more economical and practical design of 3-layer polymer composite pipe, further study should be done for the various polymer mortar, fiber-glass and different ratio of the inside/outside FRP thickness.

  • PDF