• Title/Summary/Keyword: groundwater discharge and recharge

Search Result 51, Processing Time 0.044 seconds

Groundwater Recharge and Discharge in the Urban-rural Composite Area (도농복합지역 지하수 함양과 배출에 대한 연구)

  • Lee, Byung-Sun;Hong, Sung-Woo;Kang, Hee-Jun;Lee, Ji-Seong;Yun, Seong-Taek;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.37-46
    • /
    • 2012
  • This study was conducted to identify groundwater recharge and discharge amounts of a representative urban-rural composite area located in Yongin city, Kyounggi-do, Korea. Groundwater recharge would be affected by mainly two processes in the study area: rainfall and leakage from public water pipelines including water-supply and sewage system. Groundwater recharge rate was estimated to be 13.5% by applying annual groundwater level data from two National Groundwater Monitoring Stations to the master regression curve method. Subsequently, the recharge amounts were determined to be $13,253{\times}10^3m^3/yr$. Leakage amounts from water-supply and sewage system were estimated to be $3,218{\times}10^3$ and $5,696{\times}10^3m^3/yr$, respectively. On the whole, a total of the recharge amounts was $22,167{\times}10^3m^3/yr$, of which 60% covers rainfall recharge and 40% pipeline leakage. Groundwater discharge occurred through three processes in the composite area: baseflow, well pumping, and discharge from urban infrastructure including groundwater infiltration into sewage pipeline and artificial extraction of groundwater to protect underground facilities from submergence. Discharge amounts by baseflow flowing to the Kiheung agricultural reservoir and well pumping were estimated to be $382{\times}10^3$ and $1,323{\times}10^3m^3/yr$, respectively. Occurrence of groundwater infiltration into sewage pipeline was rarely identified. Groundwater extraction amounts from the Bundang subway line as an underground facility were identified as $714{\times}10^3m^3/yr$. Overall, a total of the discharge amounts was determined to be $2,419{\times}10^3m^3/yr$, which was contributed by 29% of artificial discharge. Even though groundwater budget of the composite area was identified to be a surplus, it should be managed for a sound groundwater environment by changing deteriorated pipelines and controlling artificial discharge amounts.

지하수 유동 모텔을 이용한 지하수위 변동법의 적용성 분석

  • 구민호;이대하
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.28-31
    • /
    • 2002
  • The water level fluctuation (WLF) method is a conventional method for quantifying groundwater recharge by multiplying the specific yield to the water level rise. A 2-D unconfined flow model with a time series of the recharge rate is developed. It is used for elucidating the errors of the WLF method which is implicitly based on the tank model where the horizontal flow in the saturated zone is ignored. Simulations show that the recharge estimated by the WLF method is underestimated for the observation well near the discharge boundary. This is due to the fact that the hydraulic stress resulting from the recharge is rapidly dissipating by the horizontal flow near the discharge boundary Simulations also reveal that the recharge was significantly underestimated with increase in the hydraulic conductivity and the recharge duration, and decrease in the specific yield.

  • PDF

Minimum Entropy Deconvolution을 이용한 지하수 상대 재충진양의 시계열 추정법

  • 김태희;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.574-578
    • /
    • 2003
  • There are so many methods to estimate the groundwater recharge. These methods can be categorized into four groups. First groupis related to the water balance analysis, second group is concerned with baseflow/springflow recession, and third group is interested in some types of tracers; environmental tracers and/or temperature profile. The limitation of these types of methods is that the estimated results of recharge are presented in the form of an average over some time period. Forth group has a little different approach. They use the time series data of hydraulic head and specific yield evaluated from field test, and the results of estimation are described in the sequential form. But their approach has a serious problem. The estimated results in forth typeof methods are generally underestimated because they cannot consider the discharge phase of water table fluctuation coupled with the recharge phase. Ketchum el. at. (2000) proposed calibrated method, considering recharge- and discharge-coupled water table fluctuation. But the dischargeis considered just as the areal average with discharge rate. On the other hand, there are many methods to estimate the source wavelet with observed data set in geophysics/signal processing and geophysical methods are rarely applied to the estimation of groundwater recharge. The purpose this study is the evaluation of the applicability of one of the geophysical method in the estimation of sequential recharge rate. The applied geophysical method is called minimum entropy deconvolution (MED). For this purpose, numerical modeling with linearized Boussinesq equation was applied. Using the synthesized hydraulic head through the numerical modeling, the relative sequenceof recharge is calculated inversely. Estimated results are very concordant with the applied recharge sequence. Cross-correlations between applied recharge sequence and the estimated results are above 0.985 in all study cases. Through the numerical test, the availability of MED in the estimation of the recharge sequence to groundwater was investigated

  • PDF

Effect of the climate change on groundwater recharging in Bangga watershed, Central Sulawesi, Indonesia

  • Sutapa, I Wayan
    • Environmental Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.87-94
    • /
    • 2017
  • This study was conducted to determine the effect of the climate change to the level of groundwater recharging. This research was conducted on the watershed of Bangga by using the Soil Water Balance of MockWyn-UB model. Input data compose of evapotranspiration, monthly rainfall, watershed area, canopy interception, heavy rain factor and the influence of climate change factors (rainfall and temperature). The conclusion of this study indicates that there is a decreasing trend in annual groundwater recharge observed from 1995 to 2011. The amount of groundwater recharge varied linearly with monthly rainfall and between 3% to 25% of the rainfall. This result implies that rain contributed more than groundwater recharge to runoff and evaporation and the groundwater recharge and Bangga River discharge depends largely on the rainfall. In order to increase the groundwater recharge in the study area, reforestation programmes should be intensified.

Discharge Characteristics of the Chusan Spring, Ulleung Island (울릉도 추산용출소의 용출 특성)

  • Cho, Byong-Wook;Lee, Byeong-Dae
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.6
    • /
    • pp.37-45
    • /
    • 2018
  • The source of Chusan Spring water in the Ulleungdo is the precipitation in the Nari caldera basin, which permeates in the Trachitic pumice and tuff area and moves downward, outflowing at the lithologic boundary between the trachyte and Nari tuff. It is known that the discharge rate of the Chusan Spring is large enough to be used for the small hydroelectric power generation, but the exact discharge rate and hydrogeologic characteristics have not been known. The discharge rates of the Spring were measured 11 times, which ranged from $15,220m^3/d$ to $36,278m^3/d$. The discharge rates, measured by the automatic level recorder, for two-year period, were $20,000{\sim}38,000m^3/d$. The variation of discharge rates did not coincide with rainfall event, but showed daily increases of $3,000{\sim}5,000m^3/d$. The annual discharge rate excluding the evapotranspiration and the surrounding stream discharge corresponded to 70.6% of the annual precipitation of the recharge area. Therefore, meteorological observations at the Nari basin, rather than the Ulleung-do meteorological station, are more appropriate to properly interpret the discharge characteristics of the Chusam Spring and the recharge rate of the basin.

Case Study: Groundwater Recharge Hydrograph in Pyeongchang River (평창강 지하수 함양곡선 연구)

  • Kwak, Jaewon
    • Journal of Wetlands Research
    • /
    • v.23 no.2
    • /
    • pp.173-182
    • /
    • 2021
  • It is important to extract and assess low-flow recession characteristics for water resources management in the upper reaches of a stream. It is difficult to express the groundwater flow recession characteristics for streamflow synthetically. The linear recession model has been widely used by baseflow recession analysis for reason of simplicity and convenience, but recent studies show that nonlinear recession models fit well, and the relationship between the reservoir storage of shallow unconfined aquifers and the groundwater discharge was to be identified as nonlinear in the literature based on the analysis of numerous streamflow recession curves. The objective of the study is to decode these nonlinear characteristics, including evaporation loss, storage, and recharge of groundwater using streamflow. By analyzing the observed time series of streamflow from the study area, which is the Pyeongchang River basin in Korea, the main components of the underlying groundwater balance, namely, discharge, evaporation loss, storage, and recharge, can be identified and quantified. As a result of the study, depletion of groundwater by evapotranspiration losses through the water uptake of tree roots was found to bias the recession curves and the estimated reservoir parameters. The seasonality of both rainfall and potential evaporation, analysis of the recession curves, stratified according to time of the year, allowed the quantification of evapotranspiration loss as a function of a calendar month and stored groundwater storage.

Transient Groundwater Flow Modeling in Coastal Aquifer

  • Li Eun-Hee;Hyun Yun-Jung;Lee Kang-Kun;Park Byoung-Won
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.293-297
    • /
    • 2006
  • Submarine groundwater discharge (SGD) and the interface between seawater and freshwater in an unconfined coastal aquifer was evaluated by numerical modeling. A two-dimensional vertical cross section of the aquifer was constructed. Coupled flow and salinity transport modeling were peformed by using a numerical code FEFLOW In this study, we investigated the changes in groundwater flow and salinity transport in coastal aquifer with hydraulic condition such as the magnitude of recharge flux, hydraulic conductivity. Especially, transient simulation considering tidal effect and seasonal change of recharge rate was simulated to compare the difference between quasi-steady state and transient state. Results show that SGD flux is in proportion to the recharge rate and hydraulic conductivity, and the interface between the seawater and the freshwater shows somewhat retreat toward the seaside as recharge flux increases. Considered tidal effect, SGD flux and flow directions are affected by continuous change of the sea level and the interface shows more dispersed pattern affected by velocity variation. The cases which represent variable daily recharge rate instead of annual average value also shows remarkably different result from the quasi-steady case, implying the importance of transient state simulation.

  • PDF

Groundwater Balance in Urban Area (도시지역의 지하수수지)

  • Lee, Seung-Hyun;Bae, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1553-1560
    • /
    • 2011
  • The study analyzes groundwater balance with regard to the water recharge and discharge which contain urbanization components in Suyeong-gu, Busan. It also verifies the reliability and accuracy improvement on the analysis of the balance. The result of the study is viewed as preliminary data which are useful to develop, utilize and manage groundwater. The average quantity of groundwater recharge is 6,014.1 $m^3$/day in the research area during the last ten year period(from 1998 to 2007). The outflow from drainage areas to rivers and coasts is 149.3 $m^3$/day, the inflow from rivers and coasts to drainage area is 439.9 $m^3$/day. The use of the water is 4,243.0 $m^3$/day. The outflow caused by subway in line No.2 and No.3 through Suyeong-gu and the one by building an underground electric complex is 1,500.0 $m^3$/day. The leakage of water works is 6514.9 $m^3$/day. The inflow and outflow of sewerage is 5082.2 $m^3$/day from groundwater to sewer. The amount of groundwater recharge, the inflow from rivers and coasts to drainage area, and the leakage of water works belong to the amount of groundwater inflow and the total amount is 12,968.9 $m^3$/day. The amount of outflow from drainage area to rivers and coasts, the use of groundwater, outflow by subway and underground electric complex tunnel and the amount of inflow of the water to sewerage belong to the amount of outflow of groundwater and the sum amount is 13,031.5 $m^3$/day. The gap between the amount of inflow and outflow of groundwater is 62.6 $m^3$/day, which is considered to reflect the trend that the short term drop in the amount of rainfall results in the amount of groundwater recharge and that the amount of outflow from drainage area to rivers and coasts decreases.

Estimation Methods of Groundwater Recharge Rate in Small Basin (소유역의 지하수함양율 추정기법)

  • 박재성;김경호;전민우;김지수
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.76-86
    • /
    • 1999
  • It is necessary to estimate the groundwater recharge rate properly to predict the demand of groundwater and to establish the plan for the development of groundwater in the future. In this paper, A small basin in Chojung area is selected to calculate the groundwater recharge rate. In the calculation, water balance analysis, SCS-CN (Soil Conservation Service-Curve Number) method. groundwater-level analysis and hydrograph of outflow analysis are applied to this area. Data of precipitation measured by Chungju climatological station for about 10 years are used for water balance analysis and SCS-CN method. For the groundwater-level analysis. variations of groundwater-level measured from the 3 test wells in 1997's are used and stage-discharge rating curves in this area for 3 years are used for the hydrograph of outflow. The recharge rate calculated by water balance is 19%, 12.95% by SCS-CN method. 16.51% by groundwater-level analysis and 10.9% by hydrograph of outflow analysis and the overall average recharge rate is about 14.84%.

  • PDF

Estimation of Groundwater Recharge by the Water Balance Analysis using DAWAST Model (일 유출모형의 물수지 분석에 의한 지하수 함양량 추정)

  • Lee, Duk-Joo;Lee, Ho-Chun;Lee, Soon-Kwang;Kim, Tai-Cheol
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.431-434
    • /
    • 2003
  • This research developed a method for the estimation of groundwater recharge by yielding daily soil moisture content and watershed evapotranspiration from the water balance concept of the unsaturated and saturated layers in rainfall-runoff model called DAWAST. The goal of the research is to estimate the groundwater recharge fulfilling conditions of the safe discharge for any season. To meet this goal, the data of groundwater level and stream flow rate have been monitored in a study area and used to validate the model.

  • PDF