Cause and Protection of Harmonics in the Railway High Voltage System (철도 고압배전계통 고조파 현황 및 대책에 관한 연구)

  • 김귀동;창상훈;한문섭;김왕곤
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.553-558
    • /
    • 2002
  • The harmonics in railway high voltage system is due to common use of 3 phase incoming bus and doing the power converter for traction system on the electric car(or electric locomotive). This paper, we analyze the harmonics mechanism and characteristics of railway high voltage system, also we analyze the problem according to the actual measurement about influence of harmonicsontherailwayhighvoltagesystem. And we proved the countermeasure device(passive filter or L-C filter) of harmonics applies in the field. The test result, we have know that the filter is not fit. Consequently, The countermeasure of harmonics for the railway high voltage system be able to resolve by another filter.

  • PDF

Analysis of Harmonic Frequency for Return Current on the Track Circuit in Electrical Railway System (전기철도시스템에서 궤도회로 측면의 귀선전류 고조파 분석)

  • Beak, Jong-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.698-704
    • /
    • 2012
  • Electric power used in electrical vehicles flows into the substation through the feedback circuit, track circuit. Due to these power conversion equipments in electrical railroads, return current contains harmonics, and it should not affect other communication lines. In this paper, based on the return currents, we measured harmonics and analyzed an influence in railway equipments due to the harmonics. For analysis, we utilize the measured values of return currents measured in track circuits, and predictive values of those compared to the earth methods between the existing electrified sections. Applying the regulations used for Gyeongbu HSL(High Speed Line), the results of measured harmonics have found to be acceptable.

A Study on the Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads (고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Lee, Il-Moo;Kim, Joo-Rak
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.272-277
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the contol synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF

Reduction of Input Current Harmonics for Three Phase PWM Converter Systems under a Distorted Utility Voltage

  • Park, Nae-Chun;Mok, Hyung-Soo;Kim, Sang-Hoon
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.428-433
    • /
    • 2010
  • This paper proposes a harmonics reduction technique for the input currents of three phase PWM converters. The quality of the phase angle information on the utility voltage connected to the PWM converters affects their control performance. Under a distorted utility voltage, the extracted phase angle based on the synchronous reference frame PLL method is distorted. This causes large harmonics in the input currents of a PWM converter. In this paper, a harmonics reduction method that makes the input currents in the PWM converter sinusoidal even under distorted utility conditions is proposed. By the proposed method, without additional hardware, the THD (Total Harmonic Distortion) of the input currents can be readily limited to below 5% which is the harmonic current requirements of IEEE std. 519. Its validity is verified by simulations and experimental results.

Source Model for Harmonic Interaction Analysis between Renewable Energy Generators and Power Distribution System (계통 고조파와 분산형 전원의 상호작용 평가를 위한 고조파 모델에 관한 연구)

  • Cho, Sung-Min;Shin, Hee-Sang;Moon, Won-Sik;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.733-738
    • /
    • 2011
  • As increase of nonlinear loads and renewable energy generators (REGs) being connected to power distribution system via inverters, the concern on harmonic problems have increased. Recently, the harmonics evaluation method considering TDD (Total Demand Distortion) is used to analyze the effect of harmonics from inverters on power distribution quality. Harmonic current sources are typically used for simulation of nonlinear load. Most inverter type for REGs is voltage source inverter (VSI). So, harmonic voltage sources are more suitable to analyze impact of renewable energy generator on harmonics problem in power distribution system. In this paper, we presented the circuit model to analyze interaction between harmonics from nonlinear load and REGs. We verified that the harmonic analysis using the proposed circuit model is more appropriate than the harmonics evaluation method considering TDD through case study using PSCAD/EMTDC.

Evaluation of Deterioration of Concrete due to High Temperature through Harmonics (고조파 평가를 통한 콘크리트의 고온 열화 평가)

  • Hwang, Eui-Chul;Kim, Guy-Yong;Son, Min-Jae;Pyeon, Su-Jeong;Sasui, Sasui;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.146-147
    • /
    • 2021
  • In this study, the deterioration of concrete subjected to high temperature was evaluated using harmonics. When concrete is exposed to high temperatures, its mechanical properties deteriorate. In order to evaluate this deterioration, a method of analyzing the waveform of elastic waves was applied. As the heating temperature increased, the fundamental wave of the 50 kHz elastic wave passing through the concrete decreased. In addition, harmonics were generated at each temperature, and the higher the heating temperature, the greater the ratio of harmonics. The higher the compressive strength, the greater the amplitude of the fundamental wave, and this phenomenon is thought to be due to the internal structure of concrete.

  • PDF

Infuences of Harmonic Current on Electrical Characteristics of an Induction Motor (유도전동기의 전기적 특성에 미치는 고조파 전류의 영향)

  • Park Yang-Birm;Kim Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.67-72
    • /
    • 2005
  • This paper proposes the influences of harmonic current on electrical characteristics of an induction motor. Recently, a power system gets more worse as nonlinear load makes harmonics to affect energy lose of system and shorten lift of machines. In this paper, the electrical effect and THD(Total Harmonic Distortion) of harmonic current to an induction motor which is of great use in the industrial fields are measured and analyzed. A power conversion equipment(inverter) is installed to produce harmonics and variable reactors are installed to reduce the harmonics having an effect on the input terminal. Then the effects of the reactors are measured and analyzed. Also average voltage, current, power and 110 by harmonics are analyzed. The results show that Inn is increased by increasing load of the induction motor and installing reactors. And the harmonics affecting the input terminal are decreased by increasing reactor 3[mH] to 6[mH], however, average power of the induction motor is decreased. Therefore, it is very important that reactors should be carefully installed considering the merits and demerits resulting from the installation of reactors.

A Study on the Hormonic Characteristics of Typical Household Loads by Field Measurements (현장 측정에 의한 가정집 부하의 고조파 특성에 관한 연구)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Choi, Hyoung-Bumb
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.100-106
    • /
    • 2008
  • Typical household load have nonlinear loads including a personal computer, video, refrigerator, microwave oven, TV, and audio set. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides in depth analysis on harmonics field measurement of the typical household loads and harmonics simulation using EDSA program for the case study.

Harmonics Measurement of the Running Test EMU Train in Conventional Railway Lines (일반철도선로에서의 전동차 시험운행에 대한 고조파 측정연구)

  • Han, Seong-Ho;Shon, Jin-Geun;Kim, Young-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.77-83
    • /
    • 2016
  • The electric quality of train is represented by voltage and current harmonics at PT(Ratio 25,000/15/[V]) which is located between pantograph and primary winding of train transformer. In this paper, voltage and current harmonics were measured on the test EMU(electric multiple unit)train with maximum speed of 180km/h in existing railway lines(chungbuk, Taeback, Honam). As a results of test, it is found that the electric quality of train depends on the mostly operation conditions which is accelerating mode and braking mode on each sections. Voltage THD is above all 3[%] and current harmonics is monitored from lowest Harmonic to highest Harmonic in case of accelerating mode. But, highest current harmonics is not monitored in case of breaking mode. The results in this paper can help to stabilize the power device and power converter of the test EMU train.

Torque Ripple Reduction of an Interior PM Synchronous Motor by Compensating Harmonic Currents Based on Flux Linkage Harmonics

  • Nam, Myung Joon;Kim, Jong Hyun;Cho, Kwan-Yuhl;Kim, Hag-Wone;Cho, Younghoon
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1223-1230
    • /
    • 2017
  • The back emf harmonics of a permanent magnet (PM) synchronous motor is a major source of torque ripple. For torque control applications including column fitted MDPS (motor driven power steering) systems, it is essential to reduce the mechanical vibrations due to torque ripples at low speeds. In this paper, a torque ripple reduction algorithm for interior PM synchronous motors is proposed. The harmonic currents that cancel the $6^{th}$ order torque harmonic are added to the nominal dq currents for MTPA (maximum torque per ampere) operation. The compensated harmonic currents are derived from flux linkage harmonics based on a FFT analysis of the back emf harmonics. Simulation and experimental results verify that the $6^{th}$ order torque harmonic and THD of the torque ripple are reduced by compensating the dq harmonic currents.