• Title/Summary/Keyword: high intensity electric field

Search Result 72, Processing Time 0.023 seconds

Effect of Electric Fields on Flame Speed of Propagating Premixed Flames in Tube (전기장이 튜브내 예혼합화염 전파속도에 미치는 영향에 관한 연구)

  • Ryu, S.K.;Won, S.H.;Cha, M.S.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.137-143
    • /
    • 2006
  • The effect of electric fields on flame speed has been investigated experimentally by observing propagating premixed flames in a tube for methane/air mixtures. The flame speeds were measured in both the normal and micro gravity conditions to substantiate the measurements. The results show that the flame speeds were enhanced by both the AC and DC electric fields, as the flame approached to the high voltage electrode located on the one end of the tube. The enhancement of flame speed was proportional to the square root of the electric field intensity, defined as the voltage applied divided by the distance of flame from the high voltage electrode, when the electric field intensity is sufficiently large. When the electric field intensity was low, there existed critical intensities, below which the electric fields did not influence the flame speed. This critical electric field intensity correlated well with the flame speed.

  • PDF

Experimental Study on the Effect of DC Electric Field on Extinction Characteristics of Counterflow Diffusion Flame (대향류 확산화염의 소염특성에 미치는 직류전기장의 영향에 관한 실험적 연구)

  • Park, I.H.;Kim, M.K.;Won, S.H.;Cha, M.S.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.253-259
    • /
    • 2006
  • The effect of DC electric fields on the flame extinction was investigated experimentally in counterflow configurations for the methane/oxygen/nitrogen diffusion flame. The electric fields was applied by connecting the high voltage and ground terminals to the upper and lower burners, respectively. In case of having electric fields, several modes of flame extinction was observed according to the electric field intensity and strain rate defined by the exit velocity. To visualize and characterize the flame structure and intensity, planar LIF technique was adopted for OH radicals. Consequently, several length scales, including the flame width, thickness, and height from the burner tip, were introduced to explain the various flame behaviors and to characterize the flame extinctions. It was found that the variation of flame width and the chemical reaction are strongly related to a critical electric field intensity, thus the various modes of diffusion flame extinction could be observed due to the electric fields.

  • PDF

Development of Measuring Device for Electric Field on the Ground Level Using a Field Mill (필드 밀을 이용한 대지전장 측정장치 개발)

  • 송재용;김명진;길경석;천상규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.469-473
    • /
    • 2001
  • This paper describes a rotation-type field mill to measure the electric field intensity caused by thunderclouds on the ground level. The field mill developed is consisted of two isolated electrode vanes, a grounded stator and a rotor. To develop a high sensitive field mill, the principles and design rules of a rotation-type field mill are studied. Also, two types of calibration system, such as a cylindrical guard electrodes and a parallel-plate electrodes, are proposed to determine the sensitivity and frequency bandwidth of the field mill. From the calibration experiment, the frequency bandwidth and the sensitivity of the field mill arc DC ∼ 200 [MHz] and 0.267 [mV/Vm], respectively. Therefore, it can measure the electric field intensity from 73[V/m] to 18.7[kV/m].

  • PDF

The Measurement of Electromagnetic Waves caused by Surface Discharges of Solide Insulator at VHF Band Using an Antenna (안테나를 이용한 VHF대역에서 고체절연체의 연면방전에 기인한 방사전자파의 측정)

  • Kim, Ch.N.;Park, K.S.;Kim, K.C.;Lee, K.S.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.219-223
    • /
    • 2001
  • In this paper, electromagnetic waves were measured in accordance with propagating the discharge when positive and negative DC high voltage was applied to needle-plane electrdes and plane-plane electrdes that solid dielectric was inserted between the electrodes. The radiated electromagnetic waves were investigated in bandwidth of VHF($30{\sim}230$[MHz]) using an biconical antenna. In needle-plane electrodes high electric field intensity is shown in both frequency band of 90(MHz) and 170[MHz], and gradually decreasing characteric is appeared at high frequency band. However high electric field intensity is shown in both 80[MHz] and 140[MHz] in case of plane-plane electrodes configuration. And over 150[MHz] frequency band, rapidly decreasing characteristic is shown. Moreover, electric field intensity of positive DC is about $5{\sim}10$[dB] higher than negative DC.

  • PDF

Output Voltage Characteristics of HVDC Electric Field Mill Sensor for Different Speed Variables of Rotating Electrode

  • Kim, Young Sun;Park, Jae Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.2001-2006
    • /
    • 2017
  • This paper explains the effects of the weak signal of a rotating-type electric field mill sensor fabricated for measuring the intensity of the electric field generated by high-voltage direct current (HVDC) power transmission lines. The fabricated field mill consists of two isolated electrode vanes, a motor driver, and a ground part. The sensor plate is exposed to and shielded from the electric field by means of a rotary shutter consisting of a motor-driven mechanically complementary rotor/stator pair. When the uncharged sensor plate is exposed to an electric field, it becomes charged. The rotating electrode consists of several conductive vanes and is connected to the ground part, so that it is shielded. Determining the appropriate design variables such as the speed of the vane, its shape, and the distance between the two electrodes, is essential for ensuring optimal performance. By varying the speed, the weak signal characteristics which is used to signal processing and calibration experiment are quite different. Each weak signal pattern was analyzed along with the output voltage characteristics, in order to be able to determine the intensity of the electric field generated by HVDC power transmission lines with accuracy.

Electron Distribution in the GaAs-AlxGa1-x Quantum Well with the Si δ-doping Layer in a Non-central Position under the External Electric Field (비 중심 Si δ-doping 층을 갖는 GaAs-AlxGa1-x 양자우물에서 전계에 따른 전자 분포)

  • Choi, Jun-Young;Chun, Sang-Kook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.14-18
    • /
    • 2007
  • The electric property in the $GaAs-Al_{x}Ga_{1-x}$ quantum well with the Si ${\delta}-doping$ layer in a non-central position is studied through the effect of the electric field intensity on the electron distribution. The finite difference method is used for the calculation of the subband energy level and its wavefunction. In order to account for the change of the potential energy due to the charged particles, the self consistent method is employed. As the Si ${\delta}-doping$ layer becomes closer to the heterojunction interface, the electrons less affected by Coulomb scattering are greatly increased under the external electric field. Therefore, the high speed device is suggested due to the fact that the high mobility electrons can be increased by positioning the ${\delta}-doping$ layer in the quantum well and by applying the electric field intensity.

A Study on the Lightning Impulse Dielectric Characteristics of Air for the Development of Air-Insulated High Voltage Apparatuses (고전압 전력기기 개발을 위한 기중 절연파괴특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1005-1010
    • /
    • 2011
  • The accidents caused by dielectric instability have been increasing in power grid. It is important to enhance the dielectric reliability of a high voltage apparatus to reduce the damage from electrical hazards. To develop an electrically reliable high voltage apparatus, the experimental study on the electrical breakdown field strength is indispensable, as well as theoretical approach. In this paper, the lightning impulse breakdown characteristics considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only maximum electric field intensity but also utilization factors of electrode systems. The results are expected to be applicable to designing the air-insulated high voltage apparatuses.

Calculation of Radiative Electric Field Intensity of Overhead Medium-Voltage Power lines for Power Line Communication (전력선통신을 위한 고압 배전선로의 방사전계강도 계산)

  • Chun Dong-wan;Park Young-jin;Kim Kwan-ho;Shin Chull-chai
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.12A
    • /
    • pp.1136-1146
    • /
    • 2005
  • In this paper, the radiative electric field intensity due to the communication signal and conductive noise is calculated in overhead medium voltage power lines for power line communication. The input impedance is calculated by means of 2 port equivalent model of medium voltage power line network and basic transmission line theory. And then, currents is calculated by calculated input impedance and finally, the emissive electric field is calculated. The input impedance appears like a standing wave form with a fixed cycle because high reflection at the input terminal due to the characteristic impedance of medium voltage power line is very large. A calculated current and radiative electric field also appears like this form. From the measurement results, the measured results are very similar to the calculated results.

Characteristics of Electric and Mgnetic Field Profiles from Transformer and GIS Perimeters (변압기와 GIS 주변에서 전장과 자장 분포의 특성)

  • 이복희;이승칠;안창환;길형준;장석훈;박동화;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.51-58
    • /
    • 1998
  • This paper deals with the power frequency electric and magnetic profiles from transformer and gas-insulated swichgear(GIS) perimeters in the indoor power substation. Measurements of electric and magnetic field magnitudes were carried out by using single axis and three axes field meters at a height of 1[m]. The resultant electric and magnetic field profiles measured in the vicinity of the transformer were displayed as a 2-dimensional plot. The electric fields intensity are relatively low value of about 2.3~9[V/m], and the magnetic fields intensity range from 0.3 to [$20.3\mu$T]. Also, in the GIS perimeter the electric fields intensity are in the range of 2.2~2.5[V/m], and the high magnetic fields are largely localized to the intermediate section of the GIS and their amplitudes are [$1.2~39.5\mu$T]. Metal enclosures of transform and GIS play a role in reducing the electric field, and the magnetic fields are characterized by a rapid decrease with distance from the transformer and GIS enclosures.

  • PDF