• Title/Summary/Keyword: hydrogen compressing system

Search Result 10, Processing Time 0.022 seconds

Numerical Study of the Snubber of Reciprocating Hydrogen Compressing System

  • Rahman, M. Sq.;Lee, Gyeong-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1358-1365
    • /
    • 2008
  • By Computational Fluid Dynamics simulation, general information about an internal gas flow can be achieved. This will be very useful to improve flow inside the pipes and snubber system. Relating with hydrogen compressing system, which plays an important role in hydrogen energy utilization, this method should be a powerful tool to observe the flow quickly and clearly. Flow pressure characteristic analysis of hydrogen gas flowing through the snubber of a reciprocating compressor is presented in this paper. The CFD calculation of pressure pulsation and pressure loss are very close to the experiment. Therefore, consequently development of the better hydrogen compressing system will be observed with better understanding by CFD.

  • PDF

Numerical Analysis on the $2^{nd}$ Discharae-passase In Reciprocating Compressor (왕복동식 수소압축기의 2단 토출통로 유동해석)

  • Lee, G.H.;Rahman, M. Sq.;Kim, C.P.;Joung, T.W.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.3
    • /
    • pp.27-32
    • /
    • 2009
  • Numerical analysis information of a complex discharge-passage will be very useful to improve hydrogen compression system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas from cylinder going to the chamber of a reciprocating compressor are presented in this paper. Discharge-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the hydrogen compressing system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement should be done. Consequently, development of the better hydrogen compressing system will be achieved.

  • PDF

CFD Analysis on the 2nd Cylinder Discharge line in Hydrogen Reciprocating Compressor

  • Lee, Gyeong-Hwan;Woo, Ju-Sik;Shin, Yong-Han;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.695-702
    • /
    • 2010
  • Numerical analysis information will be very useful to improve fluid system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas coming to the cylinder of a reciprocating compressor are presented in this paper. Suction-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the Hydrogen system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement, such as reducing the varying flow parameters and flow reorientation should be done. Consequently, development of the better hydrogen compressing system will be achieved.

Numerical Analysis on the Working Fluid Flow of Suction-passage for Reciprocating Compressor (왕복동식 수소압축기의 흡입통로내 작동유체 유동해석)

  • Lee, Gyeong-Hwan;Rahman, Mohammad Shiddiqur;Shim, Kyu-Jin;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1201-1207
    • /
    • 2008
  • Numerical analysis information will be very useful to improve fluid system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas coming to the cylinder of a reciprocating compressor are presented in this paper. Suction-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the Hydrogen system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement, such as reducing the varying flow parameters and flow reorientation should be done. Consequently, development of the better hydrogen compressing system will be achieved.

A Study on Gas Pressure Fluctuation Characteristics inside Pipe Line Passing Through a Snubber at Hydrogen Compressor (수소압축기 스너버 관로 내부의 맥동파 특성에 관한 연구)

  • Shim, K.J.;Yi, C.S.;Akbar, Wanda Ali;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.165-171
    • /
    • 2006
  • An experiment to observe reduction of pressure fluctuation in the compressing system utilizing snubber has done. The experiment measured pressure at inlet and outlet of snubber. It used an air compressor as a model of hydrogen one. Snubber with buffer and snubber without buffer were used to get comprehensive comparison between both of that snubber. An analysis by using Fast Fourier Transform (FFT) method was conducted to verify working pressure frequency. With this method pure signal of static pressure was filtered from noisy signal. The experiment was run for several speeds of piston movement. It was controlled by adjustable frequency regulator that controled rotation of actuator motor. This was connected to the piston-reciprocating compressor with V-belt. From result obtained, the fluctuation was increasing proportionally when frequency of driver motor was increased.

  • PDF

The CFD Analysis Comparison of Several Snubbers with different Buffer Width (버퍼의 넓이가 다른 스너버의 수치해석 비교)

  • Lee, G.H.;Shim, K.J.;Lee, Y.H.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.38-43
    • /
    • 2007
  • Pulsation is an inherent phenomenon in reciprocating compressors. It interacts with piping to cause vibrations and performance problems. Indiscriminately connecting to a compressor can be dangerous and cost money in the form of broken equipment and piping, poor performance, inaccurate metering, unwanted vibration, and sometimes noise. Piping connected to a compressor can materially affect the performance and response. To minimize these detrimental effects, reciprocating compressor system should be equipped by pulsation suppression system. The system usually comprises bottle volume, called snubber. Snubber is one of the most important parts in hydrogen compressing system. It has installed reciprocating hydrogen compressor. One of these components is snubber which has function to reduce pulsation waveform and to remove the impurities in the hydrogen gas. A snubber has an inclined plate as a buffer, which is installed inside snubber. When the pressure loss and the pulsation of pressure within a snubber is minimized, the snubber could get more applicability. Therefore, a study to find an optimum geometric size on a several snubbers which have different buffer width, has been conducted using a numerical analysis.

  • PDF

Effect of Snubber-Array on Variation of Pressure Characteristics in Reciprocating Hydrogen Compression

  • Chung, Han-Shik;Rahman, M. Sq.;Lee, Gyeong-Hwan;Jin, Zhenhua;Kim, Jeong-Hyeon;Jeong, Hyo-Min
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.7
    • /
    • pp.1034-1043
    • /
    • 2009
  • Hydrogen energy is becoming popular day by day due to its renewability and pollutaaant free natures. Hydrogen gas pressure which is after passing through reciprocating compressor part has high pulsation wave form. A unit, snubber is used as compressor components to reduce the harmful pulsation waveform and to remove the impurities in the hydrogen gas. An experiment has been conducted to investigate the pulsation reduction performance of different arrangement of snubber i.e. snubber array used in reciprocating compression system. Analyzing the snubber array experimental data, it is found that the pressure fluctuations are reduced from 90.1977% ~ 92.6336% with pressure loss 1.5013% ~ 4.9034% for compressor operation at different speed which ensure the good performance of snubber-array as pulsation damper in hydrogen compressing system.

Basic design of hydrogen liquefier precooled by cryogenic refirgerator (극저온냉동기 예냉 수소액화기의 기초설계)

  • Kim, S.H.;Chang, H.M.;Kang, B.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.389-400
    • /
    • 1997
  • A thermodynamic cycle analysis is performed for refrigerator-precooled Linde-Hampson hydrogen liquefiers, including catalysts for the ortho-to-para(o-p) conversion. three different configurations of the liquefying system, depending upon the method of the o-p conversion, are selected for the analysis. After some simple and justifiable models are introduced, a general analysis program to predict the liquid yield and the figure of merit(FOM) is developed with incorporating the commercial computer code for the hydrogen properties. The discussion is focused on the effect of the two primary design parameters-the precooling temperature and the high pressrure of hydrogen. When the precooling temperature is in the range between 45 and 60 K, the optimal high pressure for the maximal liquid yield is found to be in the range between 100 to 140 bar, regardless of the o-p conversion. However, the FOM can be maximized at slightly smaller values of high pressures. It is remarkable to observe that the lower precooling temperatures are favorable since both the liquid yield and the FOM can be obtained without compressing hygrogen to extremely high pressures.

  • PDF

CFD Analysis on Discharge Passage Flow of Hydrogen Reciprocating Compressor (왕복동식 수소압축기의 토출구 유동에 관한 CFD해석)

  • Lee, Gyeong-Hwan;Rahman, Mohammad-Shiddiqur;Chung, Han-Shik;Jung, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.561-566
    • /
    • 2008
  • The reciprocating compressor is widely used in the industry field, because it has simple principle and high efficiency. In this work, in order to improve design of discharge passage line in hydrogen compression system Numerical analysis was conducted. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including velocity, pressure and turbulence kinetic energy distribution of hydrogen gas going out from the cylinder to discharge-path line are presented in this paper. Discharge-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows velocity, pressure and turbulent kinetic energy are not distributed uniformly along the passage of the Hydrogen system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement might be done.

  • PDF

Technical Trends of Hydrogen Manufacture, Storage and Transportation System for Fuel Cell Vehicle (연료전지자동차용 수소제조와 저장·운반기술동향)

  • Kil, Sang-Cheol;Hwang, Young-Gil
    • Resources Recycling
    • /
    • v.25 no.1
    • /
    • pp.48-59
    • /
    • 2016
  • The earth has been warming due to $CO_2$ gas emissions from fossil fuel cars and a ship. So the hydrogen fuel cell vehicle(FCV) using hydrogen as a fossil fuel alternative energy is in the spotlight. Hyundai Motor Company of Korea and a car companies of the US, Japan, Germany is developing a FCV a competitive. Obtained hydrogen as a by-product of the coke plant, oil refineries, chemical plants of steel mill, coal is reacted with steam at high temperatures, methane gas, manufacture of high purity hydrogen Methane Steam Reforming and hydrogen detachable reforming method using the Pressure Swing Adsorption or Membrane Reforming technical or decomposition of water to produce electricity. Hydrogen is the electronic industry, metal and chemical industries, which are used as rocket fuel, etc. are used in factories, hospitals, home of the fuel Ene.Farm system or FCV. And a method of storing hydrogen is to store liquid hydrogen and a method for compressing normal hydrogen to the hydrogen container, by storing the latest hydride or Organic chemical hydride method is used to carry the hydrogen station. Korea is currently 13 hydrogen stations in place and in operation, plans to install a further 43 places.