• Title/Summary/Keyword: illumination change

Search Result 297, Processing Time 0.025 seconds

A Study on the Operator Performance According to the Drastic Change of Illumination Level and Lighting Environment of Control Room in Nuclear Power Plants

  • Shin, Kwang Hyeon;Lee, Yong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.37-45
    • /
    • 2013
  • Objective: This study describes the change of operator performance in drastic change of illumination level, and proposes an alternative method to cope with it. Background: The control standard of illumination for nuclear power plants(NPPs) is based on the set of limit criteria for maintaining a specific illumination level. However, there is a possibility to cause human errors according to the psychological and physiological influences to operators in the situation of drastic change of illumination such as SBO(Station Black Out), so a basic study is necessary to review the current approach. Method: We assessed the visual fatigue, subjective work load and task performance according to the three illumination situations(Normal Illumination, Emergency Illumination, and Drastic Change of Illumination). Result: Research finding shows that there are not significant differences in task performance between normal illumination (1,000lx level) and emergency illumination (100lx level), only if beyond the dark adaptation limit. However, subjective work load on mental demand and visual fatigue show a potential challenge to visual performance in drastic change of illumination. Conclusion/Application: Several trials can complement this challenge in NPPs by applying 3-way communication, enhancing readability of procedures, and managing the visual factors affecting the operators' performance through a Visual Environment Management Program including visual health aspects, etc.

The design and the analysis of a LED illumination lens using the overlapped model (중첩모델을 이용한 조명용 LED 렌즈설계 및 분석)

  • You, Ilhyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.157-164
    • /
    • 2017
  • In this research, the overlapped illumination model was used for designing a freeform LED lens with a uniform illuminance distribution on its illuminating plane, and their performances and tolerances were compared. And, the illuminations on a illumination plane was measures for change with average illuminance and illuminance uniformity. As a result of the tolerance analysis about z-axis direction change, thickness change in lens and tilt change of light emission and characteristic change in LED source, overlapped model and divergent illumination model are similar to the performance about Z-axis direction change of light emission in LED source. but the uniformity illumination value in this overlapped model is more remarkably value than it in divergent illumination model about thickness change in LED lens. Also, even though the lens based on a divergent illumination model showed good performance compare to the lens based on an overlapped illumination model, the latter was less the deviation to variation of LED beam radiation ability.

The design and the analysis of a LED lens for forming a uniform illumination on an illuminating plane (균일한 조도를 위한 LED 조명용 렌즈 설계 및 분석)

  • You, Ilhyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.954-964
    • /
    • 2015
  • In this research, an overlapped illumination model was newly proposed for designing a freeform LED lens with a uniform illuminance distribution on its illuminating plane. Based on the proposed model and conventional illumination models, freeform lenses were designed and their performances and tolerances were compared. As a result of the tolerance analysis about thickness change in lens, position, size change, central direction change of light emission and characteristic change in LED source. This proposed model and divergent illumination model are similar to the performance about central direction change of light emission in LED source. but the uniformity illumination value in this proposed model is more remarkably value than it in divergent illumination model about characteristic change in LED source.

The change of pupil size after viewing three dimensional TV (2안식 입체TV 주시전후의 동공면적의 변화)

  • Cho, Am
    • Proceedings of the ESK Conference
    • /
    • 1995.04a
    • /
    • pp.187-198
    • /
    • 1995
  • The physiological change of eyes while viewing 3D TV was investigated. The change of pupil size was used as the measure of evaluation. The results are as follows: (1) The pupil size decreases after viewing 3D images. (2) The indoor illumination has a significant effect on the pupil size in both 2D and 3D cases. (3) Less change of pupil size were observed under the indoor illumination. Thus, if we only focus on the visual load on the eye, for viewing 3D images, it will be better to use indoor illumination.

  • PDF

Image Contrast Enhancement by Illumination Change Detection (조명 변화 감지에 의한 영상 콘트라스트 개선)

  • Odgerel, Bayanmunkh;Lee, Chang Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.2
    • /
    • pp.155-160
    • /
    • 2014
  • There are many image processing based algorithms and applications that fail when illumination change occurs. Therefore, the illumination change has to be detected then the illumination change occurred images need to be enhanced in order to keep the appropriate algorithm processing in a reality. In this paper, a new method for detecting illumination changes efficiently in a real time by using local region information and fuzzy logic is introduced. The effective way for detecting illumination changes in lighting area and the edge of the area was selected to analyze the mean and variance of the histogram of each area and to reflect the changing trends on previous frame's mean and variance for each area of the histogram. The ways are used as an input. The changes of mean and variance make different patterns w hen illumination change occurs. Fuzzy rules were defined based on the patterns of the input for detecting illumination changes. Proposed method was tested with different dataset through the evaluation metrics; in particular, the specificity, recall and precision showed high rates. An automatic parameter selection method was proposed for contrast limited adaptive histogram equalization method by using entropy of image through adaptive neural fuzzy inference system. The results showed that the contrast of images could be enhanced. The proposed algorithm is robust to detect global illumination change, and it is also computationally efficient in real applications.

Face Recognition Evaluation of an Illumination Property of Subspace Based Feature Extractor (부분공간 기반 특징 추출기의 조명 변인에 대한 얼굴인식 성능 분석)

  • Kim, Kwang-Soo;Boo, Deok-Hee;Ahn, Jung-Ho;Kwak, Soo-Yeong;Byun, Hye-Ran
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.7
    • /
    • pp.681-687
    • /
    • 2007
  • Face recognition technique is very popular for a personal information security and user identification in recent years. However, the face recognition system is very hard to be implemented due to the difficulty where change in illumination, pose and facial expression. In this paper, we consider that an illumination change causing the variety of face appearance, virtual image data is generated and added to the D-LDA which was selected as the most suitable feature extractor. A less sensitive recognition system in illumination is represented in this paper. This way that consider nature of several illumination directions generate the virtual training image data that considered an illumination effect of the directions and the change of illumination density. As result of experiences, D-LDA has a less sensitive property in an illumination through ORL, Yale University and Pohang University face database.

A Study on the Characteristics and Improvement Plans of Illuminance, Color Temperature, and Luminous Sources of Contemporary Korean Protestant Church - Focusing on the Churches Constructed in Seoul Since 2010 - (한국 현대 개신교 예배공간의 조도, 색온도, 광원 특성 및 개선방안에 관한 연구 - 2010년 이후 건축된 서울 지역 교회를 중심으로 -)

  • Jun, Ye-Jin;CHoi, Sang-Hun
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.4
    • /
    • pp.86-93
    • /
    • 2013
  • Illumination in church building has played an important role in making workship space more suitable for divine service. As time has changed, however, the worship space of Protestantism is no longer somber and reverent, but changing into practical and multipurpose space with bright and colorful image. This study investigates intensity of illumination of worship space during day and night respectively and figures out the change of psychological change of congregation in accordance with brightness and color temperature in worship space in order to find out preference and look into the usage and change of illumination in recent Protestantism in compliance with the needs of the time and influence. Then, result value is to be compared to Korean Standard intensity of illumination. Also, the correlation between intensity of illumination and color temperature by Kruithof's curve theory is used to identify the comfortableness of the worship space during day and nigh. And it is a common task of space designers and pastors to map out the worship space in terms of illumination suitable for its own purpose with even more modern and Korean sensibility and to create spiritual space for worshippers by collecting opinions from congregation, the main user of the space. With appropriate usage of illumination in Protestantism worship space, the atmosphere and purpose of worship can be enhanced.

Comparison of the Refracting Power and Aberration according to the Measurement Change in Illumination and Area of the Pupils (조도와 동공 영역의 측정 변화에 따른 굴절력과 수차의 비교)

  • Kim, Bong-Hwan;Han, Seon-Hee;Park, Byeong-Gyu;Hwang, Hyeon-Ju;Bae, Ye-Sol;Seo, Jeong-Bin;Yeo, Ye-Eun;Yoon, Min-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.2
    • /
    • pp.550-555
    • /
    • 2016
  • Purpose. We compared with the refracting power and aberration according to the measurement change in illumination and the pupils area by using the auto refraction instruments. Methods. In this study it were examined 64 eyes without eye disease, 21.4 (${\pm}2.54$) age, 32 (male 10, female 22) patients. Experiments in general illumination using the auto refraction instruments (HRK-8000A, Huvitz, Korea) was measured in both eyes 3 times and after scotopic for 30 minutes in a dark room blocked the light was measured in the same way. Aberration were measured coma, spherical aberration, high and low order aberrations in a general illumination (3500 lux) and low illumination (5 lux) of the pupil area 3.96 mm and 5.96 mm. Results. In the general illumination for measuring of the pupil area, the refractive power, coma, spherical aberration and low order aberration was no significant difference. In the low illumination, spherical aberration of the pupil area was $0.005({\pm}0.015){\mu}m$ in a 3.96mm, $0.014({\pm}0.020){\mu}m$ in a 5.96 mm and appeared a significant difference(p = 0.003). In general and low illumination on the results of comparing the measured values of the refractive power and aberration at the pupil area 3.96 mm, high order aberrations was $0.205({\pm}0.145){\mu}m$ in general illumination, $0.132({\pm}0.075){\mu}m$ in low illumination and appeared a significant differences(p = 0.001). High order aberrations at the pupil area 5.96 mm was $0.278({\pm}0.244){\mu}m$ in general illumination, $0.150({\pm}0.092){\mu}m$ in low illumination and appeared a significant differences(p = 0.000). Conclusions. When the eye refractive power measured by the automatic refraction does not depend on the illumination conditions and size of the observation pupil area, it was found that aberrations are affected by the illumination and the observation pupil area. It was found that the eye examination chamber illumination to obtain accurate measurement produces better results to decrease than to increase.

The change of pupil size after viewing three dimensional TV (2안식 입체TV 주시전후의 동공면적의 변화)

  • Cho, Am
    • Journal of the Ergonomics Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.25-32
    • /
    • 1995
  • The physiological change of eyes while viewing 3D TV was investigated. The change of pupil size was used as the measure of evaluation. The results are as follows : (1) The pupil size decreases after viewing 2D and 3D image and the the tendency is more critical with 3D images. (2) The indoor illumination has a significant effect on the pupil size in both 2D and 3D cases. (3) Less chage of pupil size were observed under the indoor illumination. Thus, if we only focus on the visual load on the eye, for viewing 3D image, it will be better to use indoor illumination.

  • PDF

Moving Object Detection Robust to Sudden illumination Change using Modified Texture Information (개선된 텍스쳐 정보를 이용한 갑작스러운 조명 변화에 강인한 이동 물체 탐지)

  • O, Yoe-Han;Chang, Hyung-Jin;Kim, Soo-Wan;Choi, Jin-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.268-269
    • /
    • 2008
  • Moving object detection is a fundamental technique in visual surveillance. Robust technique to enhance performance of moving object detection is required for several bad conditions in real external circumtance. In case of sudden illumination change in outdoor condition, many objects are determined as moving object though they are not really moving, but just their illumination changes. This makes the detection result untrustworthy. In this paper, robust moving object detection to sudden illumination change using gaussian mixture background model and new texture information using background from the weighted sum of recent images is proposed.

  • PDF