• 제목/요약/키워드: imaging sphere

검색결과 42건 처리시간 0.029초

Novel Technology for View Angle Performance Measurement

  • Rykowski, Ronald;Lee, Jong-Seo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1358-1361
    • /
    • 2008
  • Several different techniques currently exist for measuring display view angle performance. These include conoscopes, goniometric systems, and, most recently introduced to the market, instruments based on Imaging Sphere technology. This paper will compare measurement accuracy and speed of these various methodologies with different FPD types and even 3-D displays.

  • PDF

Full Color Large Area Flexible Plasma Displays

  • Wedding, Carol;Strbik, Oliver;Peters, Edwin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1237-1239
    • /
    • 2008
  • Imaging Systems Technology is conducting research and development in large area flexible plasma displays. These displays will be used for low cost dynamic signage and billboards. In this paper, IST will report its current progress in achieving very bright full color displays.

  • PDF

DESIGN AND DEVELOPMENT OF THE COMPACT AIRBORNE IMAGING SPECTROMETER SYSTEM

  • Lee, Kwang-Jae;Yong, Sang-Soon;Kim, Yong-Seung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.118-121
    • /
    • 2007
  • In recent years, the hyperspectral instruments with high spatial and high spectral resolution have become an important component of wide variety of earth science applications. The primary mission of the proposed Compact Airborne Imaging Spectrometer System (CAISS) in this study is to acquire and provide full contiguous spectral information with high quality spectral and spatial resolution for advanced applications in the field of remote sensing. The CAISS will also be used as the vicarious calibration equipment for the cross-calibration of satellite image data. The CAISS consists of six physical units: the camera system, the Jig, the GPS/INS, the gyro-stabilized mount, the operating system, and the power inverter and distributor. Additionally, the calibration instruments such as the integrated sphere and spectral lamps are also prepared for the radiometric and spectral calibration of the CAISS. The CAISS will provide high quality calibrated image data that can support evaluation of satellite application products. This paper summarizes the design, development and major characteristic of the CAISS.

  • PDF

EVALUATION OF THE RADIOMETRIC AND SPECTRAL CHARACTERISTICS OF THE CAISS

  • Lee, Kwang-Jae;Yong, Sang-Soon;Kim, Yong-Seung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.243-246
    • /
    • 2008
  • The Compact Airborne Imaging Spectrometer System (CAISS) was jointly designed and developed as the hyperspectral imaging system by Korea Aerospace Research Institute (KARI) and ELOP inc., Israel. The primary mission of the CAISS is to acquire and provide full contiguous spectral information with high quality spectral and high spatial resolution for advanced applications in the field of remote sensing. The CAISS consists of six physical units; the camera system, the gyro-stabilized mount, the jig, the GPS/INS, the power inverter and distributor, and the operating system. These subsystems shall be tested and verified in the laboratory before the flight. Especially the camera system of the CAISS shall be calibrated and validated with the calibration equipments such as the integrated sphere and spectral lamps. To improve data quality and availability, it is the most important to understand the mechanism of hyperspectral imaging system and the radiometric and spectral characteristics. This paper presents the major characteristics of camera system on the CAISS and summarizes the results of radiometric and spectral experiment during preliminary system verification.

  • PDF

자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰 (The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom)

  • 이해정;이주영;임근교;박훈희
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.39-47
    • /
    • 2014
  • 유방암 환자가 매년 증가함에 따라 BSGI 검사에 대한 의존도가 높아지고 검사 건수가 증가하고 있는 추세이다. 하지만 국내에서 BSGI 검사는 각 기관의 상황 및 업체권고에 따라 검사 프로토콜을 적용하고 있으며 관련 연구가 미비한 실정이다. 그러므로 본 연구에서는 영상의 질을 평가할 수 있는 팬텀을 자체적으로 제작하여 검사 프로토콜에 대해 고찰하고자 하였다. Dilon 6800 BSGI 장비를 이용하여 팬텀 내 구의 크기는 5단계로 구분하여 제작하여 실험하였다. 방사성동위원소는 $^{99m}TcO_4$를 사용하여 배후방사능과 관심영역의 비율을 2 : 4 : 8로 구분하였으며 5, 7, 10분 영상을 획득하였다. 획득된 영상은 각 구의 크기에 따라 관심영역을 설정하고 정량적, 정성적 분석을 시행하였다. 획득된 데이터는 SPSS ver.18.0을 통해 통계 분석하였다. 정량적, 정성적 분석 결과, 방사성동위원소의 주입량에 따른 각 구의 계수율은 주입량이 많을수록 계수율이 증가하였고, 구의 크기가 클수록 계수율이 증가하는 성향을 나타냈다(p<0.005). 영상획득시간에 따른 각 구의 계수율은 획득시간이 길수록 계수율이 증가하였고, 구의 크기가 클수록 증가하는 성향을 나타냈다(p<0.005). 방사성동위원소의 주입량에 따른 각 구의 대조도 잡음비는 주입량이 많을수록 증가하는 성향을 나타냈고, 8배 비율의 획득영상에서 대조도 잡음비가 가장 높았다. 또한 영상획득시간에 따른 각 구의 대조도 잡음비는 획득시간이 길수록 증가하는 성향을 나타냈고, 7분 획득영상에서 대조도 잡음비가 가장 높았다(p<0.005). 자체적으로 제작한 팬텀을 통한 정량적, 정성적 평가에서 통계적으로 유의한 차이가 있었으며, 팬텀의 유용성을 확인할 수 있었다. 또한 본 연구를 통해 장비 특성과 환경을 고려하여 BSGI 검사 프로토콜을 확인하고 활용한다면 보다 임상적 가치가 높을 것으로 사료된다.

  • PDF

Development and Verification of the Compact Airborne Imaging Spectrometer System

  • Lee, Kwang-Jae;Yong, Sang-Soon;Kim, Yong-Seung
    • 대한원격탐사학회지
    • /
    • 제24권5호
    • /
    • pp.397-408
    • /
    • 2008
  • A wide variety of applications of imaging spectrometer have been proved using data from airborne systems. The Compact Airborne Imaging Spectrometer System (CAISS) was jointly designed and developed as the airborne hyperspectral imaging system by Korea Aerospace Research Institute (KARI) and ELOP inc., Israel. The primary mission of the CAISS is to acquire and provide full contiguous spectral information with high spatial resolution for advanced applications in the field of remote sensing. The CAISS consists of six physical units; the camera system, the gyro-stabilized mount, the jig, the GPS/INS, the power inverter and distributor, and the operating system. These subsystems are to be tested and verified in the laboratory before the flight. Especially the camera system of the CAISS has to be calibrated and validated with the calibration equipments such as the integrating sphere and spectral lamps. To improve data quality and its availability, it is the most important to understand the mechanism of imaging spectrometer system and the radiometric and spectral characteristics. The several performance tests of the CAISS were conducted in the camera system level. This paper presents the major characteristics of the CAISS, and summarizes the results of performance tests in the camera system level.

혈중 산소 포화도의 정확한 공간 매핑을 위한 다중 파장 LED 단일소자를 활용한 이미징 시스템 설계 (A Simple Design of an Imaging System for Accurate Spatial Mapping of Blood Oxygen Saturation Using a Single Element of Multi-wavelength LED)

  • 김준환;유기연;송예은;유찬영;장윤채;무하마드 리아즈;케이 뜨웨 툰;아메드 알리;최승호
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권6호
    • /
    • pp.450-464
    • /
    • 2023
  • Pulse oximetry, a non-invasive technique for evaluating blood oxygen saturation, conventionally depends on isolated measurements, rendering it vulnerable to factors like illumination profile, spatial blood flow fluctuations, and skin pigmentation. Previous efforts to address these issues through imaging systems often employed red and near-infrared illuminations with distinct profiles, leading to inconsistent ratios of transmitted light and the potential for errors in calculating spatial oxygen saturation distributions. While an integrating sphere was recently utilized as an illumination source to achieve uniform red and near-infrared illumination profiles on the sample surface, its bulkiness presented practical challenges. In this work, we have enhanced the pulse oximetry imaging system by transitioning illumination from an integrating sphere to a multi-wavelength LED configuration. This adjustment ensures simultaneous emission of red and near-infrared light from the same position, creating a homogeneous illumination profile on the sample surface. This approach guarantees consistent patterns of red and near-infrared illuminations that are spatially uniform. The sustained ratio between transmitted red and near-infrared light across space enables precise calculation of the spatial distribution of oxygen saturation, making our pulse oximetry imaging system more compact and portable without compromising accuracy. Our work significantly contributes to obtaining spatial information on blood oxygen saturation, providing valuable insights into tissue oxygenation in peripheral regions.

68Ga 표지 PET/CT 검사의 최적화된 매개변수에 대한 연구 (Study of 68Ga Labelled PET/CT Scan Parameters Optimization)

  • 곽인석;이혁;김시활;문승철
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.111-127
    • /
    • 2023
  • Purpose: Gallium-68 (68Ga) is increasingly used in nuclear medicine imaging for various conditions such as lymphoma and neuroendocrine tumors by labeling tracers like Prostate Specific Membrane Antigen (PSMA) and DOTA-TOC. However, compared to Fluorine-18 (18F) used in conventional nuclear medicine imaging, 68Ga has lower spatial resolution and relatively higher Signal to Background Ratio (SBR). Therefore, this study aimed to investigate the optimized parameters and reconstruction methods for PET/CT imaging using the 68Ga radiotracer through model-based image evaluation. Materials and Methods: Based on clinical images of 68Ga-PSMA PET/CT, a NEMA/IEC 2008 PET phantom model was prepared with a Hot vs Background (H/B) ratio of 10:1. Images were acquired for 9 minutes in list mode using DMIDR (GE, Milwaukee WI, USA). Subsequently, reconstructions were performed for 1 to 8 minutes using OS-EM (Ordered Subset Expectation Maximization) + TOF (Time of Flight) + Sharp IR (VPFX-S), and BSREM (Block Sequential Regularized Expectation Maximization) + TOF + Sharp IR (QCFX-S-400), followed by comparative evaluation. Based on the previous experimental results, images were reconstructed for BSREM + TOF + Sharp IR / 2 minutes (QCFX-S-2min) with varying β-strength values from 100 to 700. The image quality was evaluated using AMIDE (freeware, Ver.1.0.1) and Advanced Workstation (GE, USA). Results: Images reconstructed with QCFX-S-400 showed relatively higher values for SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), count, RC (Recovery Coefficient), and SUV (Standardized Uptake Value) compared to VPFX-S. SNR, CNR, and SUV exhibited the highest values at 2 minutes/bed acquisition time. RC showed the highest values for a 10 mm sphere at 2 minutes/bed acquisition time. For small spheres of 10 mm and 13 mm, an inverse relationship between β-strength increase and count was observed. SNR and CNR peaked at β-strength 400 and then decreased, while SUV and RC exhibited a normal distribution based on sphere size for β-strength values of 400 and above. Conclusion: Based on the experiments, PET/CT imaging using the 68Ga radiotracer yielded the most favorable quantitative and qualitative results with a 2 minutes/bed acquisition time and BSREM reconstruction, particularly when applying β-strength 400. The application of BSREM can enhance accurate quantification and image quality in 68Ga PET/CT imaging, and an optimization process tailored to each institution's imaging objectives appears necessary.

금 나노 입자의 형태적 특성에 따른 $T_1$, $T_2$ 이완 시간의 변화 측정 (Measurements of $T_1$-and $T_2$-relaxation Time Changes According to the Morphological Characteristics of Gold Nanoparticles (GNPs))

  • 장무영;한용희;문치웅
    • Investigative Magnetic Resonance Imaging
    • /
    • 제15권1호
    • /
    • pp.48-56
    • /
    • 2011
  • 목적 : 본 연구에서는 금 나노 입자를 통한 국소 가열과 MR 온도 영상 기법을 결합한 Theragnosis 개념에 대한 가초연구로 금 나노 입자의 특성 및 제조 조건에 따른 MR 변수의 변화를 연구하였다. 대상 및 방법 : 실험실에서 제조된 구형과 막대형 금 나노 입자를 사용하였다. 구형 입자는 합성방법과 교반속도(stirring speed: rpm)를 변수로 설정하였고, 막대형 입자눈 첨가된 구형 입자의 양을 변수로 하여 조건을 다양화하였다. 금 나노 입자를 2% 아가로즈 젤에 1:1 로 혼합하여 임상용 1.5T MRI 시스템에서 신호를 획득하였고, $T_1$$T_2$ 이완시간의 측정을 위해 TR과 TE를 조절하였다. 획득한 영상의 화소별 신호 강도플 이용하여 제작한 소프트웨어로 $T_1$$T_2$ 이완곡선을 추정하였고, 통계 분석으로 유의성을 검증하였다. 결과 : 구형 입자의 평균 $T_1$ 값은 $1.86{\pm}0.04$초, 막대형은 평균 $2.08{\pm}0.04$초로 막대형이 더 걸게 측정되었고, 반면 평균 $T_2$ 값은 구형과 막대형 각각 $57{\pm}2.4$ ms와 $35.45{\pm}0.1$ ms로 구형 나노 입자에서 더 길게 측정되었다. 결론 : 금 나노 입자의 형태적 특성 및 제조 조건에 따른 MR 영상 변수 $T_1$$T_2$ 이완시간의 변화를 확인하였다. 금 나노 입자를 이용한 MR 영상 연구의 수행 시 금 나노 입자의 형태와 제조 조건에 따른 적절한 TR과 TE로 최적화된 영상을 얻을 수 있을 것으로 기대된다.

마이크로-CT 뼈 영상 분석을 위한 구 정합 기반 해면뼈의 자동 분할 (Automatic Segmentation of Trabecular Bone Based on Sphere Fitting for Micro-CT Bone Analysis)

  • 강선경;김영운;정성태
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제3권8호
    • /
    • pp.329-334
    • /
    • 2014
  • 본 논문에서는 마이크로 CT 영상에서 해면뼈의 형태학적 분석을 위하여 해면뼈를 자동 분할하는 방법을 제안한다. 제안된 방법에서는 임계값을 이용하여 뼈 영역을 추출하고 뼈의 바깥쪽 경계선을 검출한다. 뼈 영역의 각 복셀에 대하여 구 정합을 적용하여 해당 복셀을 중심으로 하는 최대 크기의 구를 구한다. 이 구에 뼈의 바깥쪽 경계선이 포함되면 이 구에 포함된 복셀들은 치밀뼈로 분류되고 그렇지 않으면 해면뼈로 분류된다. 제안된 방법을 쥐의 15개 대퇴골 원위부 영상에 적용하였으며 사람이 수작업으로 분할한 결과와 비교 실험을 수행하였다. 분할된 해면뼈에 대하여 BV/TV, Tb.Th, Tb.Sp, Tb.N의 네 가지 형태학적 지표자를 측정하였다. 회귀분석과 Bland-Altman 방법으로 비교해본 결과 BV/TV, Tb.Th, Tb.Sp, Tb.N 모두 신뢰할 만한 수준의 범위 안에 있었다. 또한 구 정합 방법은 단순하게 구현할 수 있으면서도 3차원 정보를 이용함으로써 해면뼈를 정확하게 분할할 수 있음을 알 수 있었다.