• Title/Summary/Keyword: in-situ reference electrode

Search Result 7, Processing Time 0.023 seconds

In-Situ Analysis of Overpotentials in Direct Methanol Fuel Cell by Using Membrane Electrode Assembly Composed of Three Electrodes (삼전극으로 구성된 막전극접합체를 이용한 직접메탄올 연료전지의 실시간 과전압 분석)

  • Jung, Namgee;Cho, Yoon-Hwan;Cho, Yong-Hun;Sung, Yung-Eun
    • Korean Journal of Materials Research
    • /
    • v.28 no.6
    • /
    • pp.330-336
    • /
    • 2018
  • In this study, a membrane electrode assembly(MEA) composed of three electrodes(anode, cathode, and reference electrode) is designed to investigate the effects of methanol concentration on the overpotentials of anode and cathode in direct methanol fuel cells(DMFCs). Using the three-electrode cell, in-situ analyses of the overpotentials are carried out during direct methanol fuel cell operation. It is demonstrated that the three-electrode cell can work effectively in transient state operating condition as well as in steady-state condition, and the anode and cathode exhibit different overpotential curves depending on the concentration of methanol used as fuel. Therefore, from the real-time separation of the anode and cathode overpotentials, it is possible to more clearly prove the methanol crossover effect, and it is expected that in-situ analysis using the three-electrode cell will provide an opportunity to obtain more diverse results in the area of fuel cell research.

Assessment of In-Situ Solid-State Reference Electrode for Monitoring Corrosion of Steel Rebar in Simulated Concrete Environments (모의 콘크리트 환경에서 강철 철근의 부식을 모니터링하기 위한 현장 고체 기준 전극 평가)

  • Karthick, Subbiah;Park, TaeJoon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.281-282
    • /
    • 2023
  • The solid-state reference electrodes made of polyaniline-coated MnO2 (SSRE-PAM) and their electrochemical characteristics were studied in simulated concrete pore solutions (SCPS) containing 0 and 3.5% NaCl. Saturated calomel electrodes (SCE) have been used to conduct electrochemical studies on the stability behavior of SSRE-PAM. Open circuit potential (OCP) and potentiodynamic polarization techniques were used to assess the corrosion performance of steel rebar exposed in SCPS with 0 and 3.5% NaCl using SSRE-PAM. The results demonstrate that the SSRE-PAM was capable of identifying steel rebar in a concrete environment that was either passive or active. Potentiodynamic polarization parameters such as Ecorr and Icorr for steel rebar in SCPS containing 0 and 3.5%)NaCl are greater than that of the passive condition (0% NaCl). All the studies validate the importance of using SSRE-PAM for corrosion monitoring applications in concrete structures.

  • PDF

Effect of Poly(ethylene glycol) dimethyl ether Plasticizer on Ionic Conductivity of Cross-Linked Poly[siloxane-g-oligo(ethylene oxide)] Solid Polymer Electrolytes

  • Kang, Yongku;Seo, Yeon-Ho;Kim, Dong-Wook;Lee, Chang-Jin
    • Macromolecular Research
    • /
    • v.12 no.5
    • /
    • pp.431-436
    • /
    • 2004
  • Cross-linked network solid polymer electrolytes were prepared by means of in situ hydrosilylation between poly[hydromethylslioxane-g-oligo(ethylene oxide)] and diallyl or triallyl group-containing poly(ethylene glycols). The conductivities of the resulting polymer electrolytes were greatly enhanced upon the addition of poly(ethylene glycol) dimethyl ether (PEGDME) as an ion-conducting plasticizer. Conductivities of the cross-linked polymer electrolytes were more dependent on the molecular weight of PEGDME than on the cross-linkers. The maximum conductivity was found to be 5.6${\times}$10$\^$-4/ S/cm at 30$^{\circ}C$ for the sample containing 75 wt% of PEGDME (M$\_$n/ =400). These electrolytes exhibited electrochemical stability up to 4.5 V against the lithium reference electrode. We observed reversible electrochemical plating/stripping of lithium on the nickel electrode.

Preparation of Pt/porous Gold Electrode for CO Oxidation (CO 가스 산화를 위한 백금/다공성 골드 전극의 개발)

  • Shin, So-Hyang;Kim, He-Ro;Oh, Cheon-Seok;Ko, Jae-Wook;Kim, Young-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.4
    • /
    • pp.27-32
    • /
    • 2011
  • Management of gas safety is becoming important with increasing use of gas facilities. U-safety system is being promoted as part of national management of gas, and thus real-time and in-situ gas sensor should be developed. Detection method for When the gas sensor is installed in gas conduit, explosion may be likely, because hydrocarbon gases is usually used the difference of thermal resistance between reference and working electrode. Therefore, it is required to detect the hydrocarbons, such as $CH_4$ and CO, at room temperature via electrochemically catalytic reaction. In this study, Pt nanoparticle was doped on the porous gold powder by electrolytic plating method, and then it was used as catalytic electrode for CO oxidation. For Pt/PAu electrode, approximately 21% of CO conversion was obtained. It is noted that Pt/PAu electrode could be used to react the oxidation of hydrocarbon gases at room temperature via applying of external voltage.

Fabrication of Anodic Aluminum Oxide on Si and Sapphire Substrate (실리콘 및 사파이어 기판을 이용한 알루미늄의 양극산화 공정에 관한 연구)

  • Kim Munja;Lee Jin-Seung;Yoo Ji-Beom
    • Korean Journal of Materials Research
    • /
    • v.14 no.2
    • /
    • pp.133-140
    • /
    • 2004
  • We carried out anodic aluminum oxide (AAO) on a Si and a sapphire substrate. For anodic oxidation of Al two types of specimens prepared were Al(0.5 $\mu\textrm{m}$)!Si and Al(0.5 $\mu\textrm{m}$)/Ti(0.1 $\mu\textrm{m}$)$SiO_2$(0.1 $\mu\textrm{m}$)/GaN(2 $\mu\textrm{m}$)/Sapphire. Surface morphology of Al film was analyzed depending on the deposition methods such as sputtering, thermal evaporation, and electron beam evaporation. Without conventional electron lithography, we obtained ordered nano-pattern of porous alumina by in- situ process. Electropolishing of Al layer was carried out to improve the surface morphology and evaluated. Two step anodizing was adopted for ordered regular array of AAO formation. The applied electric voltage was 40 V and oxalic acid was used as an electrolyte. The reference electrode was graphite. Through the optimization of process parameters such as electrolyte concentration, temperature, and process time, a regular array of AAO was formed on Si and sapphire substrate. In case of Si substrate the diameter of pore and distance between pores was 50 and 100 nm, respectively. In case of sapphire substrate, the diameter of pore and distance between pores was 40 and 80 nm, respectively

On-site Water Nitrate Monitoring System based on Automatic Sampling and Direct Measurement with Ion-Selective Electrodes

  • Kim, Dong-Wook;Jung, Dae-Hyun;Cho, Woo-Jae;Sim, Kwang-Cheol;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.350-357
    • /
    • 2017
  • Purpose: In-situ monitoring of water quality is fundamental to most environmental applications. The high cost and long delays of conventional laboratory methods used to determine water quality, including on-site sampling and chemical analysis, have limited their use in efficiently managing water sources while preventing environmental pollution. The objective of this study was to develop an on-site water monitoring system consisting mainly of an Arduino board and a sensor array of multiple ion selective electrodes (ISEs) to measure the concentration of $NO_3$ ions. Methods: The developed system includes a combination of three ISEs, double-junction reference electrode, solution container, sampling system consisting of three pumps and solenoid valves, signal processing circuit, and an Arduino board for data acquisition and system control. Prior to each sample measurement, a two-point normalization method was applied for a sensitivity adjustment followed by an offset adjustment to minimize the potential drift that could occur during continuous measurement and standardize the response of multiple electrodes. To investigate its utility in on-site nitrate monitoring, the prototype was tested in a facility where drinking water was collected from a water supply source. Results: Differences in the electric potentials of the $NO_3$ ISEs between 10 and $100mg{\cdot}L^{-1}$ $NO_3$ concentration levels were nearly constant with negative sensitivities of 58 to 62 mV during the period of sample measurement, which is representative of a stable electrode response. The $NO_3$ concentrations determined by the ISEs were almost comparable to those obtained with standard instruments within 15% relative errors. Conclusions: The use of the developed on-site nitrate monitoring system based on automatic sampling and two-point normalization was feasible for detecting abrupt changes in nitrate concentration at various water supply sites, showing a maximum difference of $4.2mg{\cdot}L^{-1}$ from an actual concentration of $14mg{\cdot}L^{-1}$.

A Study on the Metal Mesh for CuNx-Cu-CuNx Multi-layer Touch Electrode by Reactive Magnetron Sputtering (Reactive Magnetron Sputtering 적용 CuNx-Cu-CuNx 적층형 Metal Mesh 터치센서 전극 특성 연구)

  • Kim, Hyun-Seok;Yang, Seong-Ju;Noh, Kyeong-Jae;Lee, Seong-Eui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.414-423
    • /
    • 2016
  • In the present study, the $CuN_x-Cu-CuN_x$ layer the partial pressure ratio Cu metal of Ar and $N_2$ gas using a DC magnetron sputtering device, was generated by the In-situ method. $CuN_x$ layer was able to obtain a surface reflectance reduction effect from the advantages of the process and the external light. $CuN_x$ layer is gas partial pressure, DC the Power, the deposition time variable transmittance in response to the thickness and partial pressure ratio, the reflectance was measured. $Ar:N_2$ gas ratio 10:10(sccm), DC power 0.35 A, was derived Deposition time 90 sec optimum conditions. Thus, according to the optimal thickness and the composition ratio was derived surface reflectance of 20.75%. In addition, to derive the value of ${\Delta}$ Ra surface roughness of 0.467. It was derived $CuN_x$ band-gap energy of about 2.2 eV. Thus, to ensure a thickness and process conditions can be absorbed to maximize the light in a wavelength band in the visible light region. As a result, the implementation of the $12k{\Omega}$ base line resistance of using the Cu metal. This is, 5 inch Metal mesh TSP(L/S: $4/270{\mu}m$) is in the range of the reference operation.