• Title/Summary/Keyword: incinerator

Search Result 372, Processing Time 0.028 seconds

A Study on Mercury Emission Factor for Environmental Impact Assessment of Municipal Waste Incinerator (소각장 환경영향평가시 수은 배출 계수에 관한 연구)

  • Chun, Mee-Kyung;Park, Seok-Soon
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.113-125
    • /
    • 1998
  • The amount of mercury emitted from an incinerator depends on the properties of waste, combustion condition, and control devices. Mercury concentration in air proportionates to the increase of incinerator installation. The purpose of this study is to provide a method for determination of mercury emission factor which can predict the amount of mercury emitted from each incinerator specifically. Case study was performed for N municipal waste incinerator. Based on the method presented in this paper, we obtained mercury emission factor as 1.85~1.95 g Hg/t at N Municipal Waste Incinerator and this result was regarded as reasonable when compared with existing mercury emission factor in reference cases. Fluorescent lamps turned out to be the most important source(44.4%) of mercury in municipal waste and its amount will tend to increase, while batteries become less significant. In addition, medical waste is one of the major source of mercury.

  • PDF

Analysis of the relationship between operational condition and temperature distribution in a small incinerator (소형 소각로에서 운전조건과 온도분포 사이의 관계 분석)

  • Kim, Sung-Joon;Park, Jong-Hwan;Chun, Bong-Jun
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.63-70
    • /
    • 2000
  • One aims to find out how the operation condition of secondary inlet angle effects the temperature distribution inside a small incinerator. A finite volume commercial code, PHONICS, is used to simulate the temperature field in an incinerator. The computational grid system is constructed by Multi-Block technique. The governing equations based on the curvilinear coordinates are used. Numerical experiments are done with the five variations of secondary air inlet. The temperature distribution is quantified by the statistical deviation of temperature in an incinerator. The computational analysis says that the certain angle of secondary air inlet could improve the uniformity of temperature distribution in an incinerator.

  • PDF

DNA-adducts and Exposure to Endocrine Disrupting Chemicals (내분비장애물질에 대한 노출과 DNA-adduct 생성)

  • Yang, Mi-Hee
    • Environmental Analysis Health and Toxicology
    • /
    • v.21 no.4 s.55
    • /
    • pp.375-380
    • /
    • 2006
  • Endocrine disrupting chemicals (EDC) have been emphasized due to their threats in human health. Waste incinerator emission has been emphasized as a source of EDC including polychlorinateddibenzofurans(PCDD/F) and other carcinogenic polycyclic aromatic hydrocarbons (PAHs). Urinary 1-hydroxypyrene (1-OHP) has been used as an exposure biomarker for the PAHs. On the other hand, etheno-DNA adducts, e.g. 1, $N^6-ethenodeoxyadenosine({\varepsilon}dA)$, has been developed as an useful effective or response biomarker for carcinogenesis. Thus, I investigated association between urinary 1-OHP and ${\varepsilon}dA$ levels due to distance from an incinerator which was built more 10 years ago in the middle of a farm in P city. I designated the EDC-high and low exposed group due to distance from the incinerator, i.e. within 2.5km and $5.0{\sim}7.5km$ from the incinerator, respectively. The study subjects were age and sex-matched males and females (mean age, $61.3{\pm}9.6$ yrs; total 40 persons, male, 10; female, 10 for the each group). Urinary 1-OHP and ${\varepsilon}dA$ were analyzed with HPLC-FD and IP-HPLC-FD, respectively. As results, the distance from the incinerator was not associated with urinary 1-OHP nor ${\varepsilon}dA$ levels (p=0.43 and 0.82, respectively). On the other hand, urinary ${\varepsilon}dA$ levels were significantly higher in the hyperlipidemia group (N=10) than normal group (N=30). In conclusion, urinary 1-OHP nor ${\varepsilon}dA$ levels can not be suggested as an incinerator-related exposure nor effective biomarker. However, not only distance from the incinerator bot also systemic approaches including wind and soil contamination are required to assume exposure levels of incinerator-related EDC.

Optimization of Incinerator Controllers using Artificial Neural Networks

  • Mackin, Kenneth J.;Fukushima, Ryutaro;Fujiyoshi, Makoto
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.334-337
    • /
    • 2003
  • The emission of dioxins from waste incinerators is one of the most important environmental problems today, It is known that optimization of waste incinerator controllers is a very difficult problem due to the complex nature of the dynamic environment within the incinerator. In this paper, we propose applying artificial neural networks to waste incinerator controllers. We show that artificial neural networks can project the emission of dioxins with a fair degree of accuracy.

  • PDF

The Study of Numerical Simulation on the Thermal Flow Performance for the Design of Low Emission Stoker Type Municipal Waste Incinerator (저공해 스토커형 도시폐기물 소각로 설계를 위한 열유동 수치해석 연구)

  • 전영남;송형운;김미환
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.543-551
    • /
    • 2002
  • A Numerical simulation on the thermal flow performance was carried out to propose the incinerator type for the domestic refuses and to investigate the design factor and operating conditions. The SSTI(Standard Stoker Type Incinerator) proposed in this study was modified from the type with central f)ow. It has the characteristics of good mixing between refuse and hot combustion gas in primary combustion chamber and between unburned gas inflowing and secondary air jet in secondary chamber. By predictive results, the SSTI was no recirculation zone in secondary chamber so that mixing time was increased with high residence time. It has good characteristics of combustion and low emission. Parametric screening studies have been understood with phenomenon of combustion in incinerator.

Development of the Small Wastes Incinerator with High Combustion Efficiency (연소효율이 우수한 소형 소각로의 개발)

  • 한돈희;하대성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.81-85
    • /
    • 2000
  • In order to reduce emission of air pollutants from spot incineration, it is required to develope the combustion chamber of small wastes incinerator having combustion efficiency. The characteristics of combustion of the incinerator with combustion chamber having tangential angels with surface of 45$^{\circ}$of air supply nozzles were studied in accordance with non-grate, fixed-grate and shaking-grate in the combustion chamber. Combustion conditions were evaluated with combustion efficiency, emission of hazardous gases, temperatures, ignition loss of ash and so on. Combustion efficiencies were shown 73.9% for non-gate, 81.1% for fixed-grate and 89.0% for shaking-grate. Emissions of CO were revealed 6.52 ppm for non-grate, 273 ppm for fixed-grate and 224 for shaking-grate. Comprehensively evaluated, combustion conditions got better in order of shaking-grate, fixed-grate and non-grate. This study suggests that small wastes incinerator should have shaking-or fixed-grate in combustion chamber to get better combustion condition even though at expensive cost of manufacturing.

  • PDF

Polymer Waste Incineration by Oxygen Enriched Combustion (사업장폐기물의 순산소 소각기술)

  • Han, In-Ho;Choi, Kwang-Ho;Choung, Jin-Woo
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.132-139
    • /
    • 2000
  • Oxygen enriched incineration can increase the incineration capacity for wastes and dramatically reduce air pollutant emissions such as CO and dioxine by the allowing complete combustion of wastes in incinerator. Furthermore, this technology is proven to have many benefits including an energy-saving, cost-effective, and versatile application for diverse wastes compared with the conventional air incineration technology. The reduced pollutant emissions in flue gas and higher incineration efficiency are also available when the oxygen enriched air is used for the high temperature incineration systems. On the basis of the experimental results the oxygen enrichment system is successfully applied to the rotary kiln incinerator for industrial wastes. The oxygen enriched incineration system could be allowed more compact design of incinerator and flue gas treatment system due to both increasing incineration capacity and reducing flue gas volume. Therefore, oxygen enriched incineration technology is becoming highlighted in the waste incinerator which strongly require more stable efficiency and environmentally friendly and safe operationPut Abstract text here.

  • PDF

Combustion Characteristics of Municipal Wastes in Pyrolysis Incinerator (열분해 소각시설에서의 일반폐기물의 연소특성)

  • Park, Myung-Ho
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.149-156
    • /
    • 2011
  • In case of domestic pyrolysis dry distillation gassification technology, it stays at the stage of its early introduction and development. Moreover, the companies possessed of this technology are limited to Japan and some countries in Europe, and domestic operative performance of this system is nominal, so there exist a lot of difficulties in securing its basic data. In addition, considering its operation and management, there happens a corrosion of metals by the production of corrosive gases in time of combustion of waste, and there arise a problem of occurrence of low temperature corrosion on exterior casing or gas ducts of a combustion chamber due to the high temperature corrosion around the burner of an incinerator, lowering the durability of an incinerator. Therefore, this study looked at the problems arising in time of incineration by understanding the characteristics of the pyrolysis dry distillation gassification incinerating facility, and did research on the improvement plan for durability of an incinerator for more economic, efficient waste incineration.

The study of combustion gas characteristic by incinerator operation condition. (소각로 운영조건에 따른 연소배가스 특성 연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.66-72
    • /
    • 2010
  • This study was done to analyze the condition of combustion exhaust gas that is produced according to incinerator operating condition in A area Kyonggido. The boiler exhaust gas temperature, the oxygen concentration of boiler, the outgassing temperature of Semi Drying Sorber(SDS), the temperature of catalytic reactor, the concentration of NOx, SOx, CO, Hcl and Dust were investigated by change the temperature of incinerator. The concentration of SOx, CO, HCL and DUST were below 5 ppm as increase the temperature of incinerator however the concentration of NOx was increased from 40 ppm to 70 ppm as increase the temperature of incinerator. The boiler exhaust gas temperature and the temperature of catalytic reactor were not changed however the oxygen concentration of boiler was decreased gradually as increase the temperature of incinerator.

Effects of the angle of secondary air inlet on the uniformity of temperature distribution inside an incinerator (2차 공기 주입각이 소각로 내부의 온도 분포 균일도에 미치는 영향)

  • Kim S. J.;Min I. H.;Park M. H.;Park M. J.
    • Journal of computational fluids engineering
    • /
    • v.5 no.3
    • /
    • pp.8-15
    • /
    • 2000
  • This research is aimed to find out how the inlet angle of secondary air affects the uniformity of temperature distribution inside a small incinerator. A commercial code, PHOENICS, is used to simulate the thermal-flow field of an incinerator. The computational grid system is constructed by Multi-Block technique provided by PHOENICS. Numerical experiments are done with the five different angles of secondary air inlet. The uniformity of temperature distribution is evaluated by checking the standard deviation of temperature distribution in an incinerator. The computational results show that there is the minimum value of standard deviation at the certain angle of secondary air inlet, which means that there is an optimum angle of secondary air inlet that could improve the uniformity of temperature distribution in an incinerator. The optimum angle of secondary air inlet is between 30 degree and 45 degree in this particular case.

  • PDF