• Title/Summary/Keyword: indoor environmental factors

Search Result 288, Processing Time 0.032 seconds

Evaluation of Indoor Environmental Factors in Office Building with Underfloor Air-Conditioning (UFAC) System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.36-45
    • /
    • 2001
  • During the last decade, an increasing interest in Underfloor Air-Conditioning (UFAC) systems has emerged. The purpose of this paper is to evaluate the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. The physical measurements and the Interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation (POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey .

  • PDF

Estimation of Nitrogen Dioxide Source Generation and Ventilation Rate in Residence Using Multiple Measurements in Korea

  • Chung, Moon-Ho;Yang, Won-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.12a
    • /
    • pp.45-50
    • /
    • 2004
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Alt hough technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor NO2 concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and NO2 source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential NO2 deposition constant of 1.05 hr-1, and 1.36 ACH in Seoul, with the measured residential NO2 deposition constant of 0.94 hr-1. Source strengths of N02 were 15.8 ${\pm}$ 18.2 ${\mu}$g/m3${\cdot}$hr and 44.7 ${\pm}$ 38.1 ${\mu}$g/m3${\cdot}$hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

Estimation of Ventilation and Generation Rates Using Nitrogen Dioxide Measurements of Indoor and Outdoor in Houses (주택 실내.외 이산화질소 측정을 이용한 환기량 및 발생량 추정)

  • Yang, Won-Ho;Im, Sung-Guk;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1069-1073
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ generation rate were estimated. Mean of ventilation rate was 1.41 ACH in houses, assuming a residential N02 deposition constant of 0.94 $hr^{-1}$. Mean generation rate of $NO_2$ was 16.5 ppbv/hr. According to house characterization, inside smoking and family number were higher $NO_2$ generation rates, and apartment was higher than single-family house. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

A Study on the Design Prototype Development of Underfloor Air-Conditioning System(UFAC) for Improving Indoor Environment (바닥급기 공조시스템(UFAC)을 적용한 작업공간의 실내환경 평가기법 개발연구)

  • 정광섭;한화택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.325-336
    • /
    • 2000
  • During the last decade, an increasing interest in Underfloor Air-Conditioning(UFAC) systems has emerged. The purpose of this paper is to evaluate comprehensively the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. In this paper, the physical measurements and the interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation(POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey.

  • PDF

Estimation of NO$_2$ Source Generation and Ventilation rate in Residence by Multiple Measurements

  • Won Ho, Yang;Gi Yeong, Lee
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.05a
    • /
    • pp.155-160
    • /
    • 2003
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor $NO_2$ concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential $NO_2$ deposition constant of 1.05 $hr^{-1}$, and 1.36 ACH in Seoul, with the measured residential $NO_2$ deposition constant of 0.94 $hr^{-1}$. Source strengths of $NO_2$ were 15.8 $\pm$ 18.2 ${\mu}g$/$m^3$.hr and 44.7 $\pm$ 38.1${\mu}g$/$m^3$.hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

Characterization of Indoor Air Quality Using multiple Measurements of Nitrogen Dioxide and Volatile Organic Compounds

  • Son, Bu-Soon;Yang, Won-Ho;Sohn, Jong-Ryeal;Kim, Dae-Won;Jung, Soon-Won;Kim, Young-Hee
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.293-298
    • /
    • 2005
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Indoor and outdoor NO$_2$ and VOCs(benzene, toluene, xylene) concentrations were measured every 3 days for 60 consecutive days in 30 houses in Seoul, Asan and Daegu, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, NO$_2$ and VOCs source strengths (ppb/hr) and deposition constant (K, hr$^{-1}$) were estimated. Deposition constants of NO$_2$, toluene and xylene were 0.98 ${\pm}$ 0.28, 0.71 ${\pm}$ 0.24 and 0.74 ${\pm}$ 0.53 hr$^{-1}$, respectively. Source strengths of NO$_2$, toluene and xylene were 16.28 ${\pm}$ 7.47,31.25 ${\pm}$ 38.45 and 23.45 ${\pm}$ 19.67 ppb/hr, respectively In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

A Study on the Comparative Analysis and Improvement of Indoor Environmental Factor in Green Building Rating Systems (국내외 친환경건축물 인증제도 실내 환경 관련 부문 비교분석 및 개선안 연구)

  • Joh Hahn
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.4 s.57
    • /
    • pp.21-28
    • /
    • 2006
  • To promote environmentally responsible architectural practice, many nations have established their own green building rating system. Among other criteria, recently the indoor environmental quality section has been paid great attention due to Sick Building Syndrome, as this believed to caused by polluted indoor environment. In this context, indoor environmental quality is one of very important sections of each green building rating system and closely related to the very happiness of building users. The goal of this research is to compare and analyze the indoor environmental sections of three green building rating systems, GBCC, LEED v2.1, and BREEAM Office 2005, and find a direction for the improvement of GBCC. First, the three rating systems are analyzed in general to compare the importance of indoor environmental factors in each system. Second, the indoor environmental factors are reclassified within related sub-categories for the comparable analysis. Finally, based upon the comparable analysis, directions for the improvement of GBCC are as follows: 1. GBCC's h4r Environment Section needs to clarify its VOCs criteria based upon types of finish materials. 2. Sound Environment Section's noise control criteria needs to be revised based upon types of building usages and application method. 3. An indoor lighting related section needs to be included in GBCC, as even though light is the one of the most important factors in indoor environment, it has not been included in GBCC yet. 4. The sub-section of Confortable Indoor Environment Section related to the resting space and the universal accessibility are not in accord with the goal of green building rating system. These items need to be dealt within general building codes. 5. The rating evaluation structure and process need to be streamlined.

Effect of indoor environmental factors on the physical symptoms of dental hygienists (실내 환경 요인이 치과위생사의 신체증상에 미치는 영향)

  • Hong, Min-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.2
    • /
    • pp.197-204
    • /
    • 2014
  • Objectives : The purpose of the study is to examine the effect of the indoor environmental factors of dental hygienists on physical symptoms. Methods : The subjects were 210 dental hygienists in dental hospitals and clinics in Seoul, Gyeonggi Province, Incheon and South Chungnam Province from May 1 to June 20, 2013. Results : There were significant differences between the presence or absence of windows in respiratory symptoms and eye symptoms. Room temperature, bad smell, and dry humidity had significant influences on physical and respiratory symptoms. Dermatological and ophthalmological symptoms were affected by dryness, smell and dusts. Dusts and bad smell also had influences on a variety of subjective symptoms. Conclusions : The indoor environments of dental hospitals and clinics affect the respiratory, dermatological, and ophthalmological symptoms because various hazardous materials are generated by the dental treatment. Therefore dental hygienists should have a correct understanding of bacteria, dusts and bio-aerosol in order to ensure the successful environmental control.

Development of an Integrated Multizone Model for Indoor Air Environment Prediction (실내공기환경 예측을 위한 통합 다구획 모델의 개발)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.17 no.9
    • /
    • pp.993-1003
    • /
    • 2008
  • Interior space in most buildings is divided into several zones. The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. An integrated multizone model to predict these environmental factors simultaneously was developed. Also, a computer program for this model was written by the language of VISUAL BASIC. The proposed model was applied to a apartment with five rooms that had been tested by Chung. Comparison of predicted results by this study with measured results by Chung showed that their variations were within 14% for airflow rates, 1% for temperatures, 12% for humidities, and 5% for concentrations. It was seen that the opening operation schedule of building has a significant effect on the air moisture md contaminant removal. Thus, this model may be available for predicting the indoor air environment and may be contributed to design the ventilation plan for controling of indoor air quality.

Sensitivity Analysis of Indoor Environment Factors along with Changes of Outdoor Air Condition (외기상태의 변화에 따른 실내 환경인자의 민감도 분석)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.2
    • /
    • pp.125-136
    • /
    • 2010
  • The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. A sensitivity analysis of indoor environment factors was carried out to grasp influences along with changes of atmospheric conditions. An integrated multizone model was used to predict these sensitivities. This model was applied to an apartment with six zones. Airflow rates are influenced very seriously by changes of wind direct or wind velocity, but are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air temperatures are influenced very directly by changes of outdoor air temperature, but are influenced very slightly by wind direction or wind velocity and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air humidities are influenced very directly by changes of outdoor air humidity, but are not influenced at all by changes of outdoor air contaminant concentration and have little or no influence by changes of wind direction, wind velocity, or outdoor air temperature. Indoor air contaminant concentrations are influenced very seriously by changes of wind direct or wind velocity, but are influenced somewhat by changes of outdoor air contaminant concentration and are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity.