• Title/Summary/Keyword: infant%2C low birth weight

Search Result 13, Processing Time 0.027 seconds

Influence of Postconceptional Age on the Renal Biomarkers in Very-Low-Birth-Weight Infants

  • Lee, Ro Sie;Shin, So Young;Jung, Won Ho;Park, Jae Hyun
    • Neonatal Medicine
    • /
    • v.28 no.2
    • /
    • pp.65-71
    • /
    • 2021
  • Purpose: We investigated whether consecutive levels of new emerging renal biomarkers, including serum cystatin C (CysC) and urinary neutrophil gelatinase-associated lipocalin (NGAL)/creatinine (Cr) ratio, were affected by postconceptional age in very-low-birth-weight (VLBW) infants. Methods: Repeatedly measured samples for each infant were divided into four groups according to postnatal age: at birth (stage I), 3 to 7 days postnatally (stage II), 8 to 28 days postnatally (stage III), and >28 days postnatally (stage IV). The association between renal biomarkers and postconceptional age was assessed using Pearson's correlation coefficient, and the mean values of renal biomarkers in the four stages were compared using repeated-measures analysis of variance. Results: For samples measured at birth, serum CysC (r=-0.358, P=0.032) and urinary NGAL/Cr ratio (r=-0.522, P=0.001) were negatively correlated with gestational age, whereas serum Cr (r=0.148, P=0.390) was not. In addition, for all samples measured, serum CysC (r=-0.209, P=0.012), urinary NGAL/Cr ratio (r=-0.536, P<0.001), and serum Cr (r=-0.311, P<0.001) were negatively correlated with postconceptional age. Compared with the mean values of the postnatal age-specific stages, serum CysC showed no significant differences in any of the four stages. However, the urinary NGAL/Cr ratio in stage IV was significantly different from those in stages I to III. Conclusion: Although urinary NGAL/Cr ratio and serum CysC were negatively correlated with postconceptional age considering renal development, serum CysC showed no significant differences in any of the four postnatal age-specific stages. Urinary NGAL/Cr ratio at >28 days postnatally seems to be more affected by postconceptional age than serum CysC in VLBW infants.

Induction of an Experimental PKU-Like Condition in Infant Rats During the First Two Weeks After Birth (신생(新生)쥐의 생후(生後) 2주간(週間)에 있어서 Phenylketonuria 적(的) 조건(條件)의 실험적(實驗的) 유도(誘導))

  • Kim, Haeng-Ja;Longenecker, John B.
    • Journal of Nutrition and Health
    • /
    • v.14 no.2
    • /
    • pp.59-70
    • /
    • 1981
  • The objective of this study is to induce the primary characteristics of phenylketonuria in infant rats during the first 2 weeks after birth. The critical biochemical parameter in the development of phenylketonuria is the elevation of plasma phenylalanine while tyrosine is maintained at a relatively low level. A PKU-like condition was induced in infant rats during the first 2 weeks after birth using a modification of our previously published procedure for the development of a temporary (1 to 3 days) PKU-like condition. Phenylalanine was administered by stomach intubation every 6 hours (starting at 6:00 a.m.) at a dose level of 400mg per kg body weight (after birth-day 2 thru 5) and 500mg per kg body weight (day 6 thru 14). Amethopterin was given at 0.00625 or 0.0125mg per kg body weight (day 3 thru 14) and p-chlorophenylalanine at 50 mg per kg body weight (day 5 thru 14) at 9:00 a.m. and 9:00 p.m. At the times measured (6,10 and 14 days) plasma phenylalanine/tyrosine (P/T) ratios were elevated from a normal value of the or less to values ranging from 6 to 15. During the second week after birth a staggering gait, abnormal stance and decreased social behavior were also observed. None of these PKU-like characteristics were apparent in the three control groups receiving (a) no phenylalanine or inhibitors, (b) phenylalanine alone, or (c) inhibitors alone. The establishment of these primary biochemical characteristics of phenylketonuria by stomach intubation of phenylalanine and a combination of low dose levels of enzyme inhibitors to infant rats provides an experimental system which should he valuable for extensive biochemical, histological and behavioral studies in phenylketonuria.

  • PDF

Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants

  • Hwang, Joon Ho;Sohn, Yong-Hak;Chang, Seong-Sil;Kim, Seung Yeon
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.8
    • /
    • pp.301-308
    • /
    • 2015
  • Purpose: We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Methods: Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ${\leq}2,300g$ or were ${\leq}36$ weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson & Johnson) were used for the blood glucose measurements. The results were compared to those obtained using laboratory equipment (D: Advia chemical analyzer, Siemens Healthcare Diagnostics Inc.). Results: The correlation coefficients between laboratory equipment and the three blood glucose self-monitoring (A, B, and C) were found to be 0.888, 0.884, and 0.900, respectively. For glucose levels ${\leq}60mg/dL$, the correlation coefficients were 0.674, 0.687, and 0.679, respectively. For glucose levels>60 mg/dL, the correlation coefficients were 0.822, 0.819, and 0.839, respectively. All correlation coefficients were statistically significant. And the values from the blood glucose self-monitoring were not significantly different from the value of the laboratory equipment, after correcting for each device's average value (P>0.05). When using laboratory equipment (blood glucose ${\leq}60mg/dL$), each device had a sensitivity of 0.458, 0.604, and 0.688 and a specificity of 0.995, 0.989, and 0.989, respectively. Conclusion: Significant difference is not found between three blood glucose self-monitoring and laboratory equipment. But correlation between the measured values from blood glucose self-monitoring and laboratory equipment is lower in preterm or low-birth-weight infants than adults.

The influencing factors on procalcitonin values in newborns with noninfectious conditions during the first week of life

  • Lee, Jueseong;Bang, Yong Hyeon;Lee, Eun Hee;Choi, Byung Min;Hong, Young Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.1
    • /
    • pp.10-16
    • /
    • 2017
  • Purpose: Although procalcitonin (PCT) level is useful for the diagnosis of neonatal sepsis, PCT reliability is inconsistent because of the varied conditions encountered in neonatal intensive care units. This study aimed to investigate PCT levels and factors influencing increased PCT levelin newborns without bacterial infection during the first week of life. Methods: In newborns hospitalized between March 2013 and October 2015, PCT levels were measured on the first, third, and seventh days after birth. Newborns with proven bacterial (blood culture positive for bacteria) or suspicious infection (presence of C-reactive protein expression or leukocytosis/leukopenia) were excluded. Various neonatal conditions were analyzed to identify the factors influencing increased PCT level. Results: Among 292 newborns with a gestational age of $35.2{\pm}3.0$ weeks and a birth weight of $2,428{\pm}643g$, preterm newborns (n=212) had higher PCT levels than term newborns (n=80). Of the newborns, 7.9% had increased PCT level (23 of 292) on the firstday; 28.3% (81 of 286), on the third day; and 3.3% (7 of 121), on the seventh day after birth. The increased PCT level was significantly associated with prenatal disuse of antibiotics (P=0.004) and surfactant administration (P<0.001) on the first day after birth, postnatal use of antibiotics (P=0.001) and ventilator application (P=0.001) on the third day after birth, and very low birth weight (P=0.042) on the seventh day after birth. Conclusion: In newborns without bacterial infection, increased PCT level was significantly associated with lower gestational age and respiratory difficulty during the first week of life. Further studies are needed for clinical applications.

Knowledge and perceptions of kangaroo mother care among health providers: a qualitative study

  • Pratomo, Hadi;Amelia, Tiara;Nurlin, Fatmawati;Adisasmita, Asri C.
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.11
    • /
    • pp.433-437
    • /
    • 2020
  • Background: Indonesia is one of the countries with the highest preterm birth rate. Preterm infants are more likely than term and normal weight infants to experience neonatal mortality and morbidity due to acute respiratory, gastrointestinal, immunologic, central nervous system, hearing, and vision problems. Kangaroo mother care (KMC) is a proven cost-effective intervention to help reduce mortality rates among preterm infants; however, it has not been fully implemented in hospitals. Purpose: Assess KMC knowledge and perceptions among health providers. Methods: This qualitative study was conducted from December 2015 to April 2016 and consisted of 21 in-depth interviews and 3 focus group discussions (FGDs). The 3 categories of health personnel in the study were clinical providers, hospital management representatives, and Indonesian Midwife Association members. Results: Most health providers know about the benefits of KMC including stabilizing temperatures, weight gain, and maternal-infant bonding and reducing human resources and labor costs. They were also aware of which newborns were eligible for KMC treatment. Their knowledge was mostly gained from observation or obtained from pediatricians and personal experience. They believed that a low birth weight infant in an incubator could not be treated with KMC and that it could only be practiced if a special gown was used when holding the baby. This perception could be caused by a lack of formal KMC training, leading to misunderstanding of its aspects. Conclusion: In conclusion, KMC knowledge of clinical providers in the 2 hospitals was sufficient, primarily due to their health-related educational background. Some perceptions could be potential barriers to or facilitate the implementation of KMC practice. These perceptions should be considered in future KMC training designs.

Systemic Candida Infection in Very Low Birth Weight Infants : Epidemiological Features Over 5 Years (극소 저체중 출생아에서 전신성 칸디다 감염 : 5년간의 역학적 특성)

  • Lee, Seung-Woo;Lee, Jeong-Eun;Lee, Ju-Young;Lee, Hyun-Seung;Lee, Jung-Hyun;Sung, In-Kyung
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.190-196
    • /
    • 2009
  • Purpose: Candida infection has increased in neonatal intensive care units (NICU). However, recent reports on systemic candida infections in preterm newborns are rare in Korea. The aim of this study was to examine the epidemiological features of systemic candida infection in very low birth weight infants (VLBW) over the past five years. Methods: We retrospectively reviewed the medical records of 19 patients with systemic candida infections in VLBW that were admitted to the neonatal intensive care units of three hospitals affiliated with the College of Medicine, The Catholic University of Korea from January 2004 to December 2008. We analyzed the birth weight, gestational age, age at diagnosis, risk factors, co-morbidity, antifungal treatment, and mortality rates among the 19 patients. Results: Systemic candida infections occurred in 19 cases (4.7%) among the VLBW infants. The mean birth weight and gestational age were 959.0$\pm$255.9 g and 26.7$\pm$2.1 weeks. The isolated Candida species were C. albicans (4), C. parapsilosis (9), C. glabrata (2), C. famata (2), and unkown subspecies (2). Most patients had various associated risk factors, including a central venous catheter, broad spectrum antibiotics, parenteral nutrition, intravenous lipid emulsion, endotracheal intubation and $H_2$ blocker therapy. There was no significant difference in the risk factors between newborns that survived and those that died with regard to the systemic candida infection, except for gestational age. Nine (47.4%) out of 19 patients with a candida infection died and four cases (21.2%) were directly related to the candida infection. Conclusion: The prevalence of systemic candida infection is increasing in VLBW infants. The majority of Candida species has shifted to C. non-albicans, especially C. parapsilosis. Because of the high mortality associated with candida infection in the NICU, prophylaxis and early treatment based on epidemiological features is necessary.

The Identification of the High-Risk Pregnacy, Usign a Simplified Antepartum Risk-Scoring System (단순화된 산전위험득점체계를 이용한 고위험 임부의 확인)

  • Jo, Jeong-Ho
    • The Korean Nurse
    • /
    • v.30 no.3
    • /
    • pp.49-65
    • /
    • 1991
  • This study was carried out to assess the problems with the pregnant women, and check out the risk-factors in the high-risk pregnancies, using a simplified antepartum risk-scoring system, which was revised from Edwards' scoring system to be suitable for Korean situaition. This instrument was included 4 categories, demographic, obstetric, medical and miscellaneous factors. This survey was based on the 1300 pregnant women who were admitted, $x^2$-test, F-test, Pearsons correation, using statistical package SAS in NAS computer system, KIST. The results of the study were as follows; 1. 1313 infants were deliveried of these 560 infants(42.7%) were born to mothers with risk-scores > 7, and 753 infants(57.3%) were born to mothers risk-scores <7. 2. Maternal age" parity, education level, of the demographic factors were significant relation statistically to identify the high risk pregnancies($X^2$=20.88, 42.87, 15.60 P < 0.01). 3. C-section, post term, incompetent cervix, uterine anomaly, polyhydramnios, congenital anomaly, sensitized RH negative, abortion, preeclampsia, excessive size infant, premature, low birth weight infanl, abnormal presentation, perinatal loss, multiple pregnancy, of the obstetric factors were significant relation statistically to identify the high risk-pregnancies. ($X^2$ = 175.96, 87.5, 16.28, 21.78, 9.46, 8. 10, 6.75, 22.9, 64.84, 6.93, 361.43, 185.55, 78.65, 45.52, P < 0.01). 4. Abnormal nutrition, anemia, UTI, other medicalcondition(pulmonary disease, severe influenza), heart disease, V.D., of the miscellaneous and medical factors, were significant relation statistically to identify the high risk-pregnancies. 5. Premature, low birth weight infant, contracted pelvis, abnormal presentation, of the risk factors were significantly related with Apgar score at 1 '||'&'||' 5 minute after birth and neonatal body weight. 6. Apgar score at 1 '||'&'||' 5 minute after, birth and neonatal body weight were significantly negative correlated with risk-score. 7. There were statistically significant difference between risk-score and Apgar score at 1 '||'&'||' 5 minute after birth, 3 group(0-3, 4-6, above 7), and neonatal body weight, 2 group(below 2.5kg, the other group) (F=104.65, 96.61, 284.92, P<0.01). 8. Apgar score at 1 '||'&'||' 5 minute after birth(below 7), and neonatal body weight(below 2.5kg), were significant relation statistically with risk score.($x^2$=65.99, 60.88, 177.07, P<0.01) were 60.8 %, 60% . 9. Correct classifications of morbid infants(l '||'&'||' 5 minute Apgar score < 7) were 77.8%, 83.8% and that of nonmorbid infants(l '||'&'||' 5 minute Apgar score > 7) were 60.8%, 60%. 10. There were statistically significant difference between dislribution of maternal risk-score among the morbid infants(l '||'&'||' 5 minute Apgar score < 7) and non morbid infants(l '||'&'||' 5 minute Apgar score> 7) ($x^2$=64.8, 58.8, P < 0.001). 11. There were statistically significant difference between distribution of morbid infants(l '||'&'||' 5 minute Apgar score < 7) and fetal death. 12. The predictivity for classifying high.risk cases was 12 % and for classifying low-risk cases was 98.3 % in 5 minute Apgar score. Suggestions for further studies are as follows; 1. Contineous prospective studies, using this newly revised scoring system are strongly recommended in the stetric service. 2. Besides risk facto~s used in this study, assessmenl of risks by factors in another scoring system and paralled studies related to perinatal outcome are strongly recommended.

  • PDF

Comparision of Maternal Charcteristics and Birth Weight among Five Different Categories of Medical Facility for Delivery in Taegu (대구시내 각급 의료기관에서 분만하는 산모들의 특성 및 출산결과의 비교 분석)

  • Song, Jung-Hup;Park, Jung-Han;Kim, Gui-Yeon;Kim, Jang-Rak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.10-20
    • /
    • 1988
  • This study was conducted to compare the maternal charactristics, and birth weight of infants delivered at five different categories of medical facility in Taegu to examine the risk level of pregnant women and children by the medical facility for delivery. The study population included 1,410 pregnant women who delivered a baby at one of nine medical facilities (3 university hospitals, 2 general hospitals, 2 private clinics, 1 midwife clinic, 1 MCH center) in Taegu in April, 1987(April and May, 1987 for K university hospital), Pregnant women were interviewed to ask the age and educational level of woman, payment of medical fee, birth order, delivery method. Birth weight of infant was obtained from medical record. Mean ages of the women delivering at the university hospitals(27.5 years) and at general hospitals(26.7 years) were higher than those at midwife clinic(25.4 years) and at MCH center(26.1 years). Also, mean years of school education were higher in women of university hospitals(12.7 years) and general hospitals (12.2 years) than in women of midwife clinic(9.2 years) and MCH center (9.3 years). The percentages of women covered by the medical insurance were far greater in the university hospitals(78.1%) and general hospitals(82.9%) than in private clinics(44.3%) , midwife clinic(29.1%) and MCH center (5.4%). Infants born at the MCH center were mostly the second birth (47.3%) while 56.0% to 61.7% of infants born at all the other medical facilities were the first birth more women delivering at the university hospitals had history of spontaneous abortion as well as still birth than the women delivering at the other medical facilities. The preform birth rate (11.4%) and low birthweight incidence rates(5.8-13.0%) in university hospitals were significantly higher than those of other medical facilities. Accordingly, c-section rates showed a wide variation among the medical facilities. Study findings revealed that most of women delivering at the university hospitals and general hospitals are in the middle of or upper socio-economic class and obstetrically high risk group regardless of socioeconomic class while the wome delivering at the midwife clinic and MCH center are low risk group of low socioeconomic class. Therefore, the data of a specific medical facility are highly limited in interpretation and can not be generalized.

  • PDF

The Optimal Pulse Oxygen Saturation in Very Low Birth Weight or Very Preterm Infants (극소 저체중 출생아에서 경피적 산소포화도의 적정 범위)

  • You, Sun-Young;Kang, Hye-Jin;Kim, Min-Jung;Chang, Mea-Young
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.320-327
    • /
    • 2011
  • Purpose: To determine the effect of changing practice guidelines designed to avoid hyperoxia or hypoxia in very low birth weight or very preterm infants. Methods: We analyzed a database of <1,500 g birth weight or <32 weeks of gestation infants who were born and admitted to the neonatal intensive care unit of Chungnam National University Hospital from January 2007 to July 2010. First, we defined the relationship between arterial partial pressure of oxygen ($PaO_2$) and pulse oxygen saturation ($SpO_2$). When we evaluated 96 pairs of $PaO_2$ and $SpO_2$ measurements, oxygen saturation was 90-94% at a $PaO_2$ of 43-79 mmHg on the oxyhemoglobin dissociation curve, according to pulse oximetry. Based on this observation, a change in practice was instituted in August 2008 with the objective of avoiding hypoxia and hyperoxia in preterm infants with targeting a $SpO_2$ 90-94% (period II). Before the change in practice, high alarms for $SpO_2$ were set at 100% and low alarms at 95% (period I). Results: Sixty-eight infants the met enrollment criteria and 38 (56%) were born during period II, after the change in $SpO_2$ targets. Demographic characteristics, except gender, were similar between the infants born in both periods. After correcting for the effect of confounding factors, the rates for mortality, severe retinopathy of prematurity, and IVH attended to be lower than those for infants in period II. No difference in the rate of patent ductus arteriosus needed to treat was observed. Conclusion: A change in the practice guidelines aimed at avoiding low oxygen saturation and hyperoxia did not increase neonatal complication rates and showed promising results, suggesting decreased mortality and improvements in short term morbidity. It is still unclear what range of oxygen saturation is appropriate for very preterm infants but the more careful saturation targeting guideline should be considered to prevent hypoxemic events and hyperoxia.

Pregnancy Outcomes in Relation to Plasma TRAP Concentration of Maternal and Umbilical Cord (임신말 모체와 제대혈의 혈장 총유리기포집 항산화능과 임신결과)

  • Ahn Hong Seok
    • Journal of Nutrition and Health
    • /
    • v.37 no.9
    • /
    • pp.817-824
    • /
    • 2004
  • The purpose of this study was to analyze the intake of antioxidant vitamins and plasma TRAP concentrations of 60 maternal-infant pairs (30 in normal term delivery group, NT; 30 in preform group, PT) We also investigated the relationship between plasma TRAP levels of maternal-umbilical cord blood and pregnancy outcomes. Mean energy intakes of NT and PT pregnant women were 93.2% and 85.4% and their protein intakes were 113.3% and 110.9% of the recommended dietary allowance (RDA), respectively. The vitamin A intakes of NT and W pregnant women were 559.7 RE and 497.8 RE, which were less than RDA. While the vitamin E and C intakes of both NT and PT pregnant women were more than RDA. The maternal plasma TRAP level of PT was 1.41 mmol/l and that of was 1.50 mmol/l, which was significantly higher than TRAP level of PT (p < 0.05) . The umblical cord plasma TRAP levels of NT and PT were 1.44 mmol/l and 1.23 mmol/l, which indicates the significant difference between those two groups (p < 0.001) . In case of comparing the TRAP level of maternal and umbilical cord blood, there was no significant difference in NT pregnant women, however, in PT group maternal the TRAP level significant higher than that of umbilical cord (p < 0.001). The length of gestation and plasma TRAP level of maternal and umbilical cord showed a positive correlation. However, other parameters of pregnancy outcomes such as birth weight, weight gain, and Apgar score were not affected by the plasma TRAP levels. Based on these results, preform infants could have a risk of oxidative stress because of low plasma TRAP level.