• Title/Summary/Keyword: instrument development

Search Result 1,447, Processing Time 0.031 seconds

A Study on Research and Development Strategies for Measuring Instrument (계측기기 연구개발 전략에 관한 연구)

  • 최만용
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.1
    • /
    • pp.109-114
    • /
    • 1997
  • In the past few decades, the measuring instrument industries have made rapid progress with increase on the demand in industries such as precision instrument, chemistry, electronics, industrial measurement and automobile. Thus, development strategy and technical advancement are required for both securing the competitiveness on products in the world market and industrial development. Intensifying competitiveness of measuring instrument is needed in the world market. It can be achieved by development of measuring instrument holding comparative priority. A development strategy should be drawn up in the long-term point of view for coping with the increasing demand of measuring instrument and securing competitiveness in the world market.

  • PDF

Ideal Topographic Simulations for Null Measurement Data

  • Su, Yan-Jen;Tung, Chi-Hong;Chang, Leh-Rong;Chen, Jin-Liang;Chang, Calvin
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.79-82
    • /
    • 2008
  • A method is described for ideally reconstructing the profile from a surface profiling measurement containing a reasonable amount of null measurement data. The proposed method can conjecture lost information and rectify irregular data that result due to bad measuring environments, signal transmission noise, or instrument-induced errors, The method adopts the concept of computer graphics and consists of several processing steps. First, a search for valid data in the neighborhood of the null data is performed. The valid data are then grouped and their contours are extracted. By analyzing these contours, a bounding box can be obtained and the general distribution of the entire area encompassing the valid and null data is determined Finally, an ideal surface model is overlaid onto the measurement results based on the bounding box, generating a complete reconstruction of the calculations, A surface-profiling task on a liquid crystal display photo spacer is used to verify the proposed method. The results are compared to those obtained through the use of a scanning electron microscope to demonstrate the accuracy of the proposed method.

Development and Validation of ESI iDART Instrument Measuring Organizational Values: An Empirical Study in Malaysia

  • OTHMAN, Abdul Kadir;HITAM, Mizan;ZAKARIA, Zuhaina;RAHMAD, Mohd Rafizi;MOHD SANUSI, Zuraidah
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.9
    • /
    • pp.157-166
    • /
    • 2022
  • The purpose of this paper is to explain the process of developing and validating the instrument to measure the university's organizational core values and sub-values known as ESI iDART. The three core values are excellence, synergy, and integrity, while the five sub-values comprise knowledge, discipline, trustworthiness, diligence, and responsibility that all staff should understand and practice. These values must be measured to examine the extent to which the staff has practiced them in their work life. With regard to methodology, the research instrument used in the study was developed using a focus group study involving 39 university staff from various departments and campuses. The instrument was later refined and validated by a group of experts from the university. In the main study, the instrument was distributed to all 17,969 university staff from all over the country. After one month, a total of 11,688 university staff participated in the survey indicating a 66% response rate. Using descriptive analysis, reliability analysis, and ANOVA, the results indicate that instrument is considered valid and reliable to be used. The major findings from the study show that organizational values increase over time. Some theoretical and managerial implications are also discussed.

The Study for Development on Earlier Evaluation Instrument of Strength of Concrete -Outline of Experiment and Investigation on Suitability of Instrument- (콘크리트 강도 조기 판정기의 개발에 관한 연구 (1) 실험 계획 및 실험기기의 적합성 검토)

  • 김화중;이도헌;윤상천;박정민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.435-440
    • /
    • 1994
  • It is considered to pressing problem that the develpment of the rapid and simple method and measuring instrument, can evaluate for quality of concrete at early period. Accordingly in this paper proposed to earlier evaluation method on quality of concrete using resistance method and ultra-sonic pulse velocity test. It was found to the possibility of development on test method and instrument through a series of fundmental investigation.

  • PDF

Validity of Instrument Development Research in Korean Nursing Research (한국의 도구개발 간호연구에서의 타당도에 대한 고찰)

  • Lee, Kyunghee;Shin, Sujin
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.6
    • /
    • pp.697-703
    • /
    • 2013
  • Purpose: This integrative review study was done to analyze methods used for validation studies in Korean nursing research. Methods: In this study, the literature on instrument development in nursing research from Research Information Sharing Service (RISS) and major nursing journal databases in Korea were examined. The MeSH search terms included 'nursing', 'instrument', 'instrument development', 'validation' and 189 articles were included in the review. Results: The most frequently reported validity type was content validity, followed by construct validity, and criterion validity. One third reported a single type of validity, and 15% of the studies demonstrated three kinds of validity at the same time. In about 40% of the studies, both content and construct validity were examined. Conclusion: The results of the study indicate that it is necessary to provide a wider variety of evidence to establish whether instruments are valid enough to use in nursing research.

A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan (대형증발계용 매시간 증발 기록계 개발에 관한 연구)

  • Bu-Yong Lee
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF

A Development of Measuring Instrument of Portable Partial Discharge for Diagnosis of GIS Installation and Application (GIS 설비 진단을 위한 포터블 부분방전 측정장치 개발 및 응용)

  • Kim, Jong-Seo;Kim, Jin-Tea;Shin, Heung-Sik;Lee, Heung-Jea
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.231-234
    • /
    • 2009
  • Recently, to the development of a highly information-oriented society to a large increase in dependence on power, Accordingly, it is need that active development and spread of preservation technology on accident prevention in operation electrical equipment. However, to lack of the use on maintenance technology of power equipment and to increase of power usage is growing deterioration of power equipment, this is a cause on casualties, property damage and the occurrence of disasters is a growing. GIS equipments which are operated from domestic except the equipment which manages from the big business are depend on a most visual inspection, and do inspection method or measuring instrument etc. a condition which is not supplied widely. Currently, many to measure instrument used in domestic is very expensive or foreign, it will be able to substitute this, the development necessity of the diagnosis technique and the measuring instrument is demanded.

Development of a Measurement Instrument for Parenting Behavior of Primary Caregivers in Early Childhood (유아기 주 양육자의 양육행위 측정도구 개발)

  • Park, Sun-Jung;Kang, Kyung-Ah
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.5
    • /
    • pp.650-660
    • /
    • 2015
  • Purpose: The purpose of this study was to develop an instrument to measure the parenting behavior of primary caregivers of children in early childhood. Methods: An instrument was developed according to Devellis's instrument development process. The participants in this study who completed the main survey were 370 mothers and grandmothers. The survey was conducted from June 1 to July 30, 2014, and collected data were analyzed using item analysis, half-split reliability and Cronbach's ${\alpha}$ coefficient, exploratory and confirmatory factor analysis, convergent validity. Results: The factor structure of the instrument showed the cumulative variance as 55.7% in the factor analysis. As a result of a confirmatory factor analysis, a four-factor structure was found to be appropriate, and the construct validity and convergent validity of the instrument were thereby confirmed. The finalized parenting behavior instrument consisted of 26 items and four independent factors: affectionate, laissez-faire, educational and impulsive. A five-point Likert scale was employed, and a higher score in a particular factor showed that most of the behaviors belonged to the factor. Conclusion: The instrument developed in this study was found to be reliable and valid, and can be used to develop parent-child relationship building.

System Requirement Review of Lunar Surface magnetometer on the CLPS program

  • Jin, Ho;Kim, Khan-Hyuk;Lee, Seongwhan;Lee, Hyojeong;Seon, Daerac;Jung, Byungwook;Jang, Yunho;Park, Hyeonhu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.40.1-40.1
    • /
    • 2020
  • The Korea Astronomy and Space Science Institute is participating as a South Korean partner in the Commercial Lunar Payload Services (CLPS)of NASA. In response, the Korea Astronomy and Space Science Institute is currently conducting basic research for the development of four candidate instrument payloads. The magnetic field instrument is one of them and it's scientific mission objective is the moon's surface magnetic field investigation. Therefore, the development requirement of the lunar surface magnetic field instrument were derived and the initial conceptual design was started. The magnetic field instrument has a 1.2 meter boom which has two three-axis fluxgate magnetometer sensors and one gyro sensor to get a attitude information of the boom. The concept of measuring the lunar surface magnetic field will carry out using multiple sensors by placing semiconductor type magnetic field sensors inside the electric box including boom mounted fluxgate sensors. In order to overcome the very short development period, we will use the KPLO (Korean Lunar Pathfinder Orbiter) magnetometer design and parts to improve reliabilities for this instrument. In this presentation, we introduce the instrument requirements and conceptual design for the Lunar surface magnetic field instruments.

  • PDF