• 제목/요약/키워드: intumescent coating

검색결과 13건 처리시간 0.027초

경년변화에 따른 내화도료의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Performance of Intumescent Coating System with Time Elapse)

  • 김대회;성시창;최동호;박수영;이세현;이종찬
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.61-64
    • /
    • 2008
  • Applying fire resistive coating to steel members is one of the general methods to secure fire resistance performance of steel members. And intumescent coating system is currently one of methods giving fire resistance to steel members. Intumescent coating system for fire resistance, however, has undesirable weaknesses that fire resistance performance of steel members is being deteriorated due to cracks and falling-offs of the coverings as time goes after completion of the coverings to the members. This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system.

  • PDF

환경시험방법에 의한 내화도료의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance Performace of Intumescent Coating System by Environmental Testing Procedure)

  • 박수영;성시창;최동호;김대회;이세현;이종찬
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • This study is designed to understand changes in fire resistance performance of intumescent coating system through follow-up tests on temperature of unexposed surface for the domestic intumescent coating system by environmental testing procedure.

  • PDF

경년변화에 따른 내화도료의 내구성에 관한 실험적 연구 (An Experimental Study on the Durability of Intumescent Coating System with Time Elapse)

  • 최동호;성시창;김대회;박수영;이세현;이종찬
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.65-68
    • /
    • 2008
  • Intumescent coating system for fire resistance has undesirable weaknesses that fire resistance performance of steel members is being deteriorated due to cracks and falling-offs of the coverings as time goes after completion of the coverings to the members. This study is designed to understand changes in durability of intumescent coating system through follow-up tests on bond strength and thickness for the domestic intumescent coating system.

  • PDF

내화도료 내구성 평가 방법 설정에 관한 연구 (The Research for the Establishment of Test Method of Durability on Intumescent Coating System)

  • 최동호
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.40-47
    • /
    • 2009
  • 현재 철골부재의 내화성능 확보를 위해서 다양한 내화피복방법이 적용되고 있으며, 따라서 이중 하나가 내화도료 피복 시스템의 적용이다. 하지만 내화도료 시스템의 경우 시공후 시간경과에 따라 균열, 탈락 등에 의한 내구성 저하 및 이에 따른 내화성능 상실의 우려가 있으며, 이에 따라 건축 설계 및 시공 초기에 시간경과에 따른 내구성 변화를 파악하여 이에 대비할 수 있는 평가방법 및 유지관리 등에 대한고려가 필요하다. 이에 본 연구에서는 시간경과에 따른 내화도료의 내구성 평가 및 이에 대한 관리방안을 제시하기 위하여 영국을 비롯한 기타 국가의 관련 자료를 조사하여 국내에 적용할 수 있는 내화도료 내구성 평가방법 및 유지관리에 필요한 기초 자료를 제시하도록 하였다.

Temperature on structural steelworks insulated by inorganic intumescent coating

  • Choi, J. Yoon;Choi, Sengkwan
    • Steel and Composite Structures
    • /
    • 제15권1호
    • /
    • pp.1-14
    • /
    • 2013
  • Predicting the fire resistance of structures has been significantly advanced by full scale fire tests in conjunction with improved understanding of compartmental fire. Despite the progress, application of insulation is still required to parts of structural steelwork to achieve over 60 minutes of fire rating. It is now recognised that uncertainties on insulation properties hinder adaptation of performance based designs for different types of structures. Intumescent coating has recently appeared to be one of most popular insulation types for steel structures, but its design method remains to be confirmed by empirical data, as technical difficulties on the determination of the material properties at elevated temperatures exist. These need to take into account of further physiochemical transitions such as moving boundary and endothermic reaction. The impetus for this research is to investigate the applicability of the conventional differential equation solution which examines the temperature rise on coated steel members by an inorganic intumescent coating, provided that the temperature-dependent thermal/mechanical insulation properties are experimentally defined in lab scale tests.

Finite element study on composite slab-beam systems under various fire exposures

  • Cirpici, Burak K.;Orhan, Suleyman N.;Kotan, Turkay
    • Steel and Composite Structures
    • /
    • 제37권5호
    • /
    • pp.589-603
    • /
    • 2020
  • This paper presents an investigation of the thermal performance of composite floor slabs with profiled steel decking exposed to fire effects from floor. A detailed finite-element model has been developed by representing the concrete slab with steel decking under of it and steel beam both steel parts protected by intumescent coating. Although this type of floor systems offers a better fire resistance, passive fire protection materials should be applied when a higher fire resistance is desired. Moreover, fire exposed side is so crucial for composite slab systems as the total fire behaviour of the floor system changes dramatically. When the fire attack from steel parts, the temperature rises rapidly resulting in a sudden decrease on the strength of the beam and decking. Herein this paper, the fire attack side is assumed from the face of the concrete floor (top of the concrete assembly). Therefore, the heat is transferred through concrete to the steel decking and reaching finally to the steel beam both protected by intumescent coating. In this work, the numerical model has been established to predict the heat transfer performance including material properties such as thermal conductivity, specific heat and dry film thickness of intumescent coating. The developed numerical model has been divided into different layers to understand the sensitivity of steel temperature to the number of layers of intumescent coating. Results show that the protected composite floors offer a higher fire resistance as the temperature of the steel section remains below 60℃ even after 60-minute Standard (ISO) fire and Fast fire exposure. Obtaining lower temperatures in steel due to the great fire performance of the concrete itself results in lesser reductions of strength and stiffness hence, lesser deflections.

실험과 계산을 통한 에폭시 계열 내화도료의 열분해에 관한 연구 (Experimental and Numerical Study of the Thermal Decomposition of an Epoxy-based Intumescent Coating)

  • 김양균
    • 한국화재소방학회논문지
    • /
    • 제30권1호
    • /
    • pp.31-36
    • /
    • 2016
  • 본 연구는 에폭시 계열 내화 도료의 열분해 특성을 파악하기 위해 열중량분석과 수치해석을 동시에 수행하였다. 에폭시 계열 내화 도료의 질량 감소 양상을 수치적으로 구현하기 위한 계산 모델이 소개되었으며, 계산 모델은 내화 도료의 여러 열분해과정을 단순화하여 4 단계의 순차적인 열분해 형태로 만들었다. 반응 속도는 Arrhenious 형태로 모델 되었고, 열중량분석을 통해 획득된 열분해 현상을 수치적으로 모사하기 위하여 화학 반응 매개변수들이 최적화되었다. 실험 결과 두 단계(two-step)와 세 단계(three-step)의 급격한 질량 감소가 질소와 공기 분위기에서 각각 나타났다. 또한 도료가 공기 분위기에 노출되었을 때 산소의 참여로 발생하는 복합적인 화학 반응들이 내화도료의 안정화를 도와 $200{\sim}500^{\circ}C$ 범위에서 질량 감소율을 낮추었다. 수치해석 결과는 실험과 비교하여 전체적으로 잘 일치하였으며 수치 모델에 포함되지 않은 $800^{\circ}C$ 이후를 제외하면 3% 미만의 오차를 보였다.

INTUMESCENT INORGANIC AND ORGANIC COATINGS

  • Kodolov, V.I.;Mikhalkina, T.M.;Shuklin, S.G.;Bystrov, S.G.;Larionov, K.I.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.130-137
    • /
    • 1997
  • Intumescent inorganic and organic coatings which dintr one from the other by the type of gas formers and the mechanisms of foam formation have been obtained and investigated. Inorganic intumescent coatings are the compositions based on water glass and mineral additives with different dispersity. Mineral additives contain adsorbed and absorbed water and carbonates which are destructed with the carbon dioxide and water evolution during the flame action on coating. The decreasing of mineral additives particle sizes under the mechanical milling with the fraction precipitation promotes the foam coke formation with less defects. Here the main structure of comparing compositions does not change. In organic coatings based on epoxy-polymers the polyammonium phosphate additive is used. It is the cabonization catalyst and the foam agent. The polyammonium phosphate of various dispersity employed is uniformly distributed on the polymeric matrix. The decreasing of the particle sizes leads to the increasing of the fire resistant properties of the intumescent coa-ting. The fire resistant analysis of the coating during more than an hour: the coating back side the temperature on plastic or wooden materials does not exceed 423K, and on metal-573K.

  • PDF

수동화재보호 재료가 적용된 구조부재의 화재하중에 대한 강도 특성 (Strength Characteristics of Passive Fire Protection Material Applied Structural Members on Fire Load)

  • 조상찬;유승수;서정관
    • 대한조선학회논문집
    • /
    • 제59권1호
    • /
    • pp.29-38
    • /
    • 2022
  • In offshore installations, fires cause the structure to lose its rigidity and it leads to structural integrity and stability problems. The Passive Fire Protection (PFP) system slows the transfer rate of fire heat and helps prevent the collapse of structures and fatality. Especially, intumescent epoxy coating is widely used in the offshore industry, and not only is the material cost expensive, but it also takes a lot of time and cost for construction. Several studies have been conducted on the efficient application and optimal design of the PFP system. However, the mechanical properties and the strength of the PFP material have not been considered. In addition, researches on the correlation between the thickness of PFP and the structural behavior were insufficient. Therefore, this study aims to analyze the thermal and mechanical effects of the PFP on the structure when it is applied to the structural member. In particular, it is intended to resolve the change in strength characteristics of the structural members as the thickness of the PFP increases.