• Title/Summary/Keyword: ion-electrode

Search Result 1,146, Processing Time 0.028 seconds

A Study on Ion Wind Characteristics of Acceleration Type Multipoint Electrode (가속형 다침전극의 이온풍 특성 연구)

  • Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.104-109
    • /
    • 2011
  • In this paper, after an acceleration typed ion wind generator which could format strong electric field in air was manufactured and installed, the effects of the electrode configuration and distance of acceleration type ion wind generator with triangle structure on the ion wind generation characteristics were investigated. As a result, the ion wind generator with curvature multipoint electrode could generate higher ion wind velocity and ion wind generation yield than others with multipoint electrode, curvature line electrode, line electrode structure. The ion wind generator with curvature multipoint electrode showed a peak ion wind velocity of 1.33[m/s] at 19.0[kV] and a ion wind generation yield of 0.12[m/Ws] at 15.0[kV].

Sodium Ion-Selective Membrane Electrode Based on Dibenzopyridino-18-Crown-6

  • Tavakkoli, Nahid
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1474-1476
    • /
    • 2004
  • A sodium ion- selective electrode based on dibenzopyridino-18-crown-6 as membrane carrier was successfully prepared. The electrode exhibits a Nernstian response for $Na^+$ ions within the concentration range of $1.0\;{\times}\;10^{-4}-1.0\;{\times}\;10^{-1}$ M. The response time of the sensor is 20 s. The sodium ion-selective electrode exhibited comparatively good selectivities with respect to alkali, alkaline earth and some transition metal ions.

Potentiometric performances of polymer membrane electrode based on cyclosporin (싸이크로스포린을 이용한 고분자막 전위차 전극)

  • Rhee Paeng, Insook
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.491-494
    • /
    • 2005
  • The main component governing selectivity in ion-selective electrodes and optodes is the ionophore. For this reason, a member of natural products that possess selective ion-binding properties have long been sought after. By applying this principle, the performance of cyclosporin used as neutral carriers for calcium selective polymeric membrane electrode was investigated. The calcium ion-selective electrode based on cyclosporin gave a good Nernstian response of 26.6 mV per decade for calcium ion in the activity range $1{\times}10^{-6}M$ to $1{\times}10^{-2}M$. The optimized calcium ion-selective electrode displayed very comparable selectivity for $Ca^{2+}$ ion against alkali and alkaline earth metal ions, $Na^{2+}$, and $Mg^{2+}$ in particular.

Influence of the Density Gradient on the Current of the Electrode Immersed in the Non-uniform Plasma (플라즈마 삽입전극의 전류에 미치는 밀도 구배의 영향)

  • Hwang, Hui-Dong;Gu, Chi-Wuk;Chung, Kyung-Jae;Choe, Jae-Myung;Kim, Gon-Ho;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.6
    • /
    • pp.504-509
    • /
    • 2011
  • The conducting current of non-uniform plasma immersed electrode consists of ion current and secondary electron emission current caused by the impinging ion current. The ion current is determined by the ion dose passing through the sheath in front of electrode and the ion distribution in front of the electrode plays an important role in the secondary electron emission. The investigation of the distributed plasma and secondary electron effect on electrode ion current was carried out as the stainless steel electrode plugged with quartz tube was immersed in the inductively coupled Ar plasma using the antenna powered by 1 kw and the density profile was measured. After that, the negative voltage was applied by 1 kV~6 kV to measure the conduction current for the analysis of ion current.

Electrode Charging Effect on Ion Energy Distribution of Dual-Frequency Driven Capacitively Coupled Plasma Etcher (이중 주파수 전원의 용량성 결합 플라즈마 식각장비에서 전극하전에 의한 입사이온 에너지분포 변화연구)

  • Choi, Myung-Sun;Jang, Yunchang;Lee, Seok-Hwan;Kim, Gon-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.3
    • /
    • pp.39-43
    • /
    • 2014
  • The effect of electrode charging on the ion energy distribution (IED) was investigated in the dual-frequency capacitively coupled plasma source which was powered of 100 MHz RF at the top electrode and 400 kHz bias on the bottom electrode. The charging property was analyzed with the distortion of the measured current and voltage waveforms. The capacitance and the resistance of electrode sheath can change the property of ion and electron charging on the electrode so it is sensitive to the plasma density which is controlled by the main power. The ion energy distribution was estimated by equivalent circuit model, being compared with the measured distribution obtained from the ion energy analyzer. Results show that the low frequency bias power changes effectively the low energy population of ion in the energy distribution.

UO22+ Ion-Selective Membrane Electrode Based on a Naphthol-Derivative Schiff's Base 2,2'-[1,2-Ethandiyl bis(nitriloethylidene)]bis(1-naphthalene)

  • Shamsipur, Mojtaba;Saeidi, Mahboubeh;Yari, Abdullah;Yaganeh-Faal, Ali;Mashhadizadeh, Mohammad Hossein;Azimi, Gholamhasan;Naeimi, Hossein;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.629-633
    • /
    • 2004
  • A new PVC membrane electrode for $UO_2^{2+}$ ion based on 2,2'-[1,2-ethanediyl bis (nitriloethylidene)]bis(1-naphthalene) as a suitable ionophore was prepared. The electrode exhibites a Nernstian response for $UO_2^{2+}$ ion over a wide concentration range ($1.0{\times}10^{-1}-1.0{\times}10^{-7}$M) with a slope of 28.5 ${\pm}$ 0.8 mV/decade. The limit of detection is $7.0{\times}10^{-8}$M. The electrode has a response time of < 20 s and a useful working pH range of 3-4. The proposed membrane sensor shows good discriminating abilities towards $UO_2^{2+}$ ion with regard to several alkali, alkaline earth transition and heavy metal ions. It was successfully used to the recovery of uranyl ion from, tap water and, as an indicator electrode, in potentiometric titration of $UO_2^{2+}$ ion with Piroxycam.

A compact mass spectrometer for plasma ion species analysis

  • ;S.A. Nikiforov
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.185-185
    • /
    • 2000
  • 플라즈마 연구 및 응용에서 플라즈마를 구성하는 이온에 대한 정보를 얻는 것은 중요하다. 특히 플라즈마 진단, 박막 증착, 플라즈마 코팅, 플라즈마 이온주입 등과 같은 플라즈마 프로세싱에서 이온들의 종류 구성비율 및 분포는 매우 중요하다. 질량분석기는 대개 큰 규모로 복잡하고 값비싼 경향이 있다. 플라즈마 교란을 최소화하면서 충분한 질량분해능을 갖고 국소적으로 이온들을 분석할 수 있는 간단하고 작은 규모의 값싼 질량분석기가 필요하다. 본 연구에서는 플라즈마 내에 존재하는 이온을 분석하기 위하여 간단하고 작은 규모의 값싼 프라즈마 이온 질량분석기를 설계, 제작하였다. 이온 질량분석기는 ion extraction part, double focusing sector magnet, ion collector로 구성되어 있다. 플라즈마에 잠기는 ion extraction part의 외부 전극에 Al2O3를 코팅하여 플라즈마 교란을 최소화하였다. 이온들의 공간적 분포를 측정하기 쉽게 하기 위하여 ion extraction part를 이동하여도 질량여과기를 통과한 후에 접속되는 초점의 위치가 Faraday ion collector 에 고정되도록 ion optical system을 설계하였다. Extracting electrode에 의하여 가속된 이온들이 sector magnet에 들어갈 때 평행이 되게 하기 위하여 여러 개의 미세구조를 갖는 Mo grids를 사용하고 immersion lens를 넣어서 이온 광학 시스템을 구성하였다. extraction electrode와 sector magnet 사이에 보조 electrode를 하나 더 넣어서 extracting electrode와 보조 electrode 사이에 immersion lens를 만들었다. 질량여과기로는 permanent magnet sector와 time-varying electrical field를 결합하여 사용하였다. Extracting electrode에 1kV 정도의 전압을 인가하여 이온들을 가속시키고 sector magnet에 톱니파 형태의 전압을 인가하여 mass spectrum을 얻었다. 이온 질량분석기를 플라즈마 장치에 적용하여 질량분해능 등의 특성을 연구하였다. Hot cathode discharge와 inductively coupled RF discharge에서 발생된 질소 플라즈마를 구성하는 이온들의 종류와 그 구성비율을 연구하였다.

  • PDF

In-line Monitoring of an Oxide Ion in LiCI Molten Salt Using a YSZ Based Oxide Ion Selective Electrode

  • Cho, Young-Hwan;Jeon, Jong-Seon;Yeon, Jei-Won;Choi, In-Kyu;Kim, Won-Ho
    • Nuclear Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.415-419
    • /
    • 2004
  • The electrode potential characteristics of a YSZ based membrane metal oxide electrode have been studied in molten LiCL at $700^{\circ}C$ by the potentiometric method. The electrode exhibited a good potential response to log[$O^2$] and data reproducibility. The calibration plot (potential vs. log[$O^2$] was found to be linear, obeying the Nernst equation. The electrode potential showed a good reversibility corresponding to increase/decrease of the oxide ion present in the molten LiCl. The physical and chemical durability appeared to be sound after several repeated uses, resulting in reproducible results. However, "the proposed electrode" failed when metallic Li was present in the melt.

Improvement of Electrical Property and Stability of Silver Nanowire Transparent Electrode Via Ion-beam Treatment (이온빔 처리를 통한 은나노와이어 전극의 전기적 특성과 안정성 향상)

  • Jung, Sunghoon;Lee, Seunghun;Kim, Do-Geun
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.6
    • /
    • pp.455-459
    • /
    • 2017
  • The development of flexible transparent electrode has been paid attention for flexible electronics. In this study, we have developed transparent electrode based on silver nanowires with improved electrical property and stability through ion-beam treatment. The energetic particles of ion-beam could sinter junctions of each silver nanowires and etch out polyvinylpyrollidone(PVP) coated on silver nanowires. The sheet resistance of silver nanowire transparent electrode was reduced by 74%, and the resistance uniformity was increased about 3 times after exposure of ion beam. Moreover, the stability at $85^{\circ}C$ of temperature and 85% of relative humidity could be also improved.

Treatment of Nitrogen Oxides in Ambient Air using a Ion-Selective Electrode (대기중 질산화물의 이온 선택성 전극에 의한 처리)

  • 안형환;우인성;강안수;이영순;김윤선
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.2
    • /
    • pp.40-49
    • /
    • 1990
  • For the determination of polluant NOx in ambient air, nitrate ion-selective electrode(ISE) was made. To comparison of NOx in each method, the nitrate-ISE, NEBA, Orion electrode were used to determinee NOx in ambient air. In this work, the concentration of NOx in ambient air was average 0.06ppm. The results were good agreement with those obtained by each method within a relative error of 3%, Absorbing efficiency of nitrogen oxides in ambient air was good for Alkali solution. The determination of nitrogen oxides in ambient air using the Aliquat 336N-PVC membrane electrode was one of the useful method. The best characteristics of the Aliquat 336N-PVC me,mbrane electrode were obtained with the ion-exchanger concentration level of 6.5-9.1 percent by weight. The optimal membrane composition, was 9.09wt.% of ion-exchanger, 30.95wt.% of PVC, 60.6wt.% of plasticizer (DBP), and 0.5mm of thickness. Under the above condition, the electrode approached the Nernstian slope most closely, and the linear response ranges produced the best results.

  • PDF