• Title/Summary/Keyword: latex gloves

Search Result 17, Processing Time 0.023 seconds

Distribution of Skin Hydration on the Hand while Wearing Latex Gloves and Inner Gloves (라텍스 장갑과 마이크로 파이버 속장갑 착용 시 손의 피부수분도 분포)

  • Roh, Sang-Hyun;Hyun, Cheol-Seung;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.5
    • /
    • pp.966-976
    • /
    • 2017
  • This study investigated the effects of wearing latex gloves with inner gloves on the skin hydration of the hands. Fifteen young males participated in the following three conditions: bare hand (BH), latex glove (LG), and latex glove with inner glove condition (LGIG) at an air temperature of $28^{\circ}C$ with 50%RH. Subjects typed a book for 120 min. The results were as follows. Skin hydration was greater for LG and LGIG than BH (p<.001), but no difference was found between LG and LGIG. Skin hydration showed greater values on the thenar and dorsum compared to the palm for both LG and LGIG (p<.05). Skin hydration on the thenar increased during the typing for LG and LGIG, but on the dorsum, palm and finger maintained after 40 min typing. There were positive relationships between hand skin hydration and hand temperature (p<.05). Subjects indicated 'much warmer' and 'more humid' for the LG and LGIG compared to the BH (p<.001), but no differences were found between LG and LGIG. In conclusion, wearing inner gloves inside latex gloves did not induce a reduction of skin hydration and hand temperature; however, significant differences were found in all measurements between bare hands and gloved hands.

Latex Allergy (라텍스 알레르기(Latex Allergy))

  • Hwang, Ji-In
    • The Korean Nurse
    • /
    • v.37 no.2
    • /
    • pp.87-92
    • /
    • 1998
  • Immdeiate hypersensitivity reactions to natural rubber and latex products pose a significant threat to patients, healthcare workers, and the general population. The purpose of this study is to summarize the clinical syomptoms of latex rubber allergy and provide guidelines for the management of latex allergy. Contact dermatitis from the nearly constant use of latex gloves during the workday has become a real problem for many health care professionals. Moreover, the patient who come in contact with these gloves or with other latex-containing equipment may show reactons. Far worse than skin problems is life-threatening anaphyaxis, which can be the first indication that a person has latex sensitivity. In conclusion, nurses shold know the latex precautions such as risk factors, adverse reactons to latex, emergent treatment and so on.

  • PDF

Comparison of Hand Grip Strength, Dexterity, and Hand Function According to the Type of Glove

  • Ro, Hyo-Lyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.3
    • /
    • pp.11-21
    • /
    • 2022
  • PURPOSE: This study examined the changes in the handgrip strength, dexterity, and hand function according to the presence or absence of gloves and types of gloves. METHODS: Seventy-six adults in their twenties (male: 24, female: 52, mean age 21.04 years) were the subjects of this study. The handgrip strength, dexterity, and hand function were evaluated with bare hands without gloves, poly gloves, and latex gloves. The handgrip strength was measured using a dynamometer, and three pinch strength tests were performed: tip pinch, lateral pinch, and three-jaw pinch. The hand dexterity was evaluated using the Minnesota manual dexterity test, and the hand function was evaluated using the Jabson-Taylor hand function test. RESULTS: There was no difference in the grip strength depending on whether the gloves were worn. The hand grip, dexterity, and hand function showed significant differences according to the type of glove. Regarding the handgrip, dexterity, and hand function, the latex glove had the best function, and the poly glove had the lowest function. CONCLUSION: There was a difference in dexterity among the hand functions but no difference in grip strength according to the type of glove. The results suggest that the use of latex gloves in daily life be recommended.

Effect of latex gloves on polymerization inhibition of addition silicone impression materials (라텍스 글러브가 시판되는 3종류 부가중합형 실리콘 인상재의 중합에 미치는 영향)

  • Kim, Soo-Hwa
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.3
    • /
    • pp.369-379
    • /
    • 2009
  • This study investigated the polymerization inhibition effect of latex gloves on addition silicone impression material. Three different kinds of addition silicone impression materials and a natural latex gloves were used in this study. The results were as follows. 1. Compared to the control group, all of those three kinds of impression materials took longer curing time in order of unwashed, alcohol and washed group, on the other hand, degloving group had shorter curing time than control group(p<0.05). 2. By the type of impression materials, there was no significant difference observed between Exafine and Twinz in ungloved group, Exafine and Imprint II in unwashed group, and Exafine and Twinz in degloving group(p>0.05). 3. The degree of polymerization at 6 minutes after mixing impression materials was evaluated by dividing its range into score 1 to 5. All of the impression materials got score 5 in control group and degloving group, which implies perfect polymerization. In unwashed group, most of them appeared to be score 2 while score 3 were most frequently observed in alcohol group and score 4 in washed group. Thus each group showed differences in the degree of polymerization(p<0.05).

  • PDF

Preparation and Properties of Insulating Rubber Gloves for Safety Protection (안전보호용 절연 고무장갑의 제조 및 특성)

  • Kim, Kong-Soo;Cho, Suk-Hyung;Kim, Sang-Ki
    • Elastomers and Composites
    • /
    • v.36 no.4
    • /
    • pp.262-267
    • /
    • 2001
  • Insulating rubber gloves with antibacterial and withstand voltage properties were prepared by blending the natural rubber latex(NRL), waterborne polyurethane(PU) and 4N-chitosan. Tensile strength of rubber glove increased with increasing amount of PU, and elongation decreased. The property of withstand voltage of rubber gloves improved with increasing leaching time, and the rubber gloves showed insulating capability of 10000V at leaching time of 3 hours. Little bacteria existed after 4N-chitosan was added to rubber gloves.

  • PDF

Bacteria reduction ratio by cleansing methods of latex gloves (라텍스 장갑의 세척 방법에 따른 세균 감소율 측정)

  • Yang, Song-Yi;Oh, Jeong-Min;Song, Da-Hye;Song, Bo-Ram;Kang, Myung-Jin;Lee, Myung-Sun;Son, Ga-Yeon;Oh, Sang-Hwan
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.4
    • /
    • pp.593-599
    • /
    • 2014
  • Objectives : Latex gloves hygiene is the most effective method to prevent infection of microorganisms and to reduce the incidence of cross infections. The aim of this study was to compare the bacteria reduction ratio of cleansing with water, liquid soap and alcohol gauze. Methods : The left side glove was the control group and the right side was the experimental group. The experimental group washed hand with water, soap, and alcohol gauze. The hand plate was inoculated by the hand and inoculated for 24 hours in $35^{\circ}C$. Results : Washing with water showed that CFU of control group was 1116.9 and that of experimental group was 302.8. Hand washing by water reduced 74.3% of bacteria. Liquid soap revealed that CFU of control group was 619.9 and that of experimental group was 8.3. Hand washing by liquid soap reduced 97.5% of bacteria. Alcohol gauze included 875.2 CFU in control group and 5.8 CFU in experimental group. Washing by alcohol gauze reduced 99.5% of bacteria. Conclusions : Based on the results, the most effective latex gloves cleansing method was recommended as the standardized hand washing with the liquid hand soap and alcohol gauze. The results can be used to improve training strategies for enhancing glove hygiene practice in dental clinic.

A Study on the Physical Properties of Heat resistance and Cut resistance of Coating Gloves for Work

  • Pyo, Kyeong-Deok;Jung, Eugene;Park, Cha-Cheol
    • Elastomers and Composites
    • /
    • v.54 no.2
    • /
    • pp.91-96
    • /
    • 2019
  • The purpose of this study was to examine the effect of different yarn twisting methods on physical properties. Plain single jersey structured fabrics were knitted from Kevlar yarn, and from Kevlar/HPPE, and from Kevlar/Basalt fiber, and from Kevlar/Glass fiber and Kevlar/Stainless steel fiber blended and core-spun yarns. and then, The fabrics were coated NBR Latex. The physical properties, including tear strength, modulus, degree of penetration, heat resistance, and cut resistance of the knitted fabrics were investigated and compared. Kevlar/HPPE blended yarn fabrics recorded the highest heat resistance (13 Sec.). and Kevlar/HPPE blended yarn fabrics had good cut resistance (Cut Level 4).

A study on wearing practice and improvement of personal protective equipment for participant handling livestock carcass infected with virulent avian infectious agents (가금류 악성 전염병 감염축 처리자의 보호 장비 착용실태 조사 및 개선에 관한 연구)

  • Lee, Hyeyeoun;Lim, Ui-Hyoung;Kim, Jong Won;Kim, Won-Il;Kang, A-Rum;Lim, Chae Woong;Hong, Chul Un;Han, Jihyeon;Kang, Seog-Jin;Kim, Bumseok
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.4
    • /
    • pp.241-248
    • /
    • 2015
  • This study was aimed to investigate factors that affected the status of wearing personal protective equipment (PPE) for handling poultry carcasses with potential exposure to virulent avian infectious agents. A large outbreak of high pathogenic avian influenza (HPAI) occurred in South Korea in 2014. Many public officers participated for euthanizing and handling livestock carcass. However, several safety issues with using PPE were revealed. Therefore, a questionnaire survey was conducted for 340 people who participated euthanasia and carcass disposal in the place where HPAI mainly occurred in 2014. It was found that 31.8% of the respondents had ever taken off their protective equipment during operations because of its inconvenience. The most inconvenient PPE was goggles (54.6%), followed by mask (20.2%), latex gloves (11.6%), shoe covers (5.9%) and protective clothing (5.3%). The main complaints about this individual PPE was unclear sight, damp emitted toward eye, sweating, tearing easily and sweating, respectively. Considering such problems of PPE, new possible directions for improvement of gloves and goggles were suggested. With newly developed rubber coating fabric gloves and conventionally using latex and fabric gloves, H3N2 influenza virus transmission experiment was conducted. Rubber coating fabric gloves showed similar efficiency for blocking virus transmission with latex laboratory gloves and were not easily torn by sharp claws of chicken. In addition, air flow control safety eyewear was suggested to minimize moisture formation. The air flow control system efficiently suppressed moisture formation inside the goggles. Therefore our study will provide more specific directions about new PPE development for safety protection of actual wearers.

Assessment of Semi-Quantitative Health Risks of Exposure to Harmful Chemical Agents in the Context of Carcinogenesis in the Latex Glove Manufacturing Industry

  • Yari, Saeed;Asadi, Ayda Fallah;Varmazyar, Sakineh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.sup3
    • /
    • pp.205-211
    • /
    • 2016
  • Excessive exposure to chemicals in the workplace can cause poisoning and various diseases. Thus, for the protection of labor, it is necessary to examine the exposure of people to chemicals and risks from these materials. The purpose of this study is to evaluate semi-quantitative health risks of exposure to harmful chemical agents in the context of carcinogenesis in a latex glove manufacturing industry. In this cross-sectional study, semi-quantitative risk assessment methods provided by the Department of Occupational Health of Singapore were used and index of LD50, carcinogenesis (ACGIH and IARC) and corrosion capacity were applied to calculate the hazard rate and the biggest index was placed as the basis of risk. To calculate the exposure rate, two exposure index methods and the actual level of exposure were employed. After identifying risks, group H (high) and E (very high) classified as high-risk were considered. Of the total of 271 only 39 (15%) were at a high risk level and 3% were very high (E). These risks only was relevant to 7 materials with only sulfuric acid placed in group E and 6 other materials in group H, including nitric acid (48.3%), chromic acid (6.9%), hydrochloric acid (10.3%), ammonia (3.4%), potassium hydroxide (20.7%) and chlorine (10.3%). Overall, the average hazard rate level was estimated to be 4 and average exposure rate to be 3.5. Health risks identified in this study showed that the manufacturing industry for latex gloves has a high level of risk because of carcinogens, acids and strong alkalisand dangerous drugs. Also according to the average level of risk impact, it is better that the safety design strategy for latex gloves production industry be placed on the agenda.

New economical and simple device for intraoperative expansion on small and medium sized soft tissue defects

  • Lee, Jun Won;Park, Seong Hoon;Lee, Seong Joo;Kim, Seong Hwan;Jeong, Hii Sun;Suh, In Suck
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.235-239
    • /
    • 2018
  • Intraoperative expansion has been used to cover small to large defects without disadvantages of the conventional tissue expanders. Various materials, for example, expanders and Foley catheters are being used. We introduce a new, convenient and economical device immediately available in the operating room, according to the defect size for intraoperative expansion, with latex gloves or balloons. The retrospective study was done with 20 patients who presented with skin and soft tissue defects. During the operation, expansion was done with latex gloves or balloons inflated with saline through an intravenous line and a three-way stopcock. After the inflation, the glove was removed and skin was covered with expanded tissue. A careful decision was made regarding the inflation volume and placement of the expander according to the defect size. There were no postoperative complications. The skin contracture and tension was minimal with a texture similar to the adjacent tissue. The new intraoperative expansion devices with latex gloves and balloons were cheap and made easily right in the operation room. The reconstruction of small to large sized skin defects can be done successfully, functionally and aesthetically without using expensive commercial materials.