• Title/Summary/Keyword: lightning warning system

Search Result 12, Processing Time 0.023 seconds

Construction and Operation Characteristics of the Automated Lightning Warning System Based on Detections of Cloud-to-Ground Discharge and Atmospheric Electric Field (낙뢰와 대기전계의 탐지를 기반으로 하는 자동낙뢰경보시스템의 구성과 운용특성)

  • Shim, Hae-Sup;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.82-88
    • /
    • 2013
  • It is important to give lightning warning prior to a cloud-to-ground (CG) discharge within an Area of Concern (AOC) because most of lightning damage and victim are usually occurred by the first lightning in the AOC. The aim of this study is to find the optimal operation conditions of the automated lightning warning systems in order to make the best use of the available data. In this paper, the test-operated results of the automated lightning alert and risk management system (ALARM) based on detections of CG discharge and eletrostatic field and optimized at probability of lightning have been described. It was possible to obtain the following warning performance parameters: probability of detection (POD), false alarm ratio (FAR), probability of lightning (POL) and failure-to-warn rate (FTW). The data obtained from trial operation for 5months were not sufficient but the first analysis of domestic lightning warning was carried out. We have observed that the evaluated statistical results through trial operation depend on the various factors such as analysis methods and criteria, topographical conditions, etc. Also we suggest some methods for improvement of POL and POD including the finding of the optimal electric field threshold level to be used, based on the high values of FAR and FTW found in this work.

The Latest Trend of Policy Plan for Mitigating Lightning damage in Advanced Countries (선진국의 뇌해경감 대처 방안의 최근 동향)

  • Eom, Ju-Hong;Cho, Sung-Chul;Yoo, Yang-Woo;Lee, Tae-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1414_1415
    • /
    • 2009
  • This paper shows the latest trend of coping plan for mitigating lightning damage in advanced countries. The mitigation measures were investigated in following fields: the organization of government and warning system, education and publicity, support program and concerned service. In results of investigations, the USA and Japan have been organized with the latest technology of warning system and the effective management of organization. So government-level mitigation measures based on the small-scaled lightning warning system need to be considered for reducing the damage of lightning in our country.

  • PDF

Development of Wireless lightning detecting and warning system (무선식 낙뢰통보시스템 개발)

  • Kim, Kyung-Man;Kwon, Tae-Woon;Sim, Kwang-Yeol;Kim, Se-Yeol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.500-503
    • /
    • 2006
  • This paper gives a Wireless lightning detecting and warning system. This system composed of transmitter and receiver. It promptly senses lightning strikes on the power lines and transmission towers by using the lightning current detection circuit in a small transmitter situated on the top of power tower, and it sends the number of lightning strikes and the ID. of the tower to patrols through the receivers. This system will be used to discover the exact location of a lightning strike.

  • PDF

A Proposal on the Development Method of a New Lightning Warning System for Effective Alerts (유효 경보를 위한 새로운 낙뢰 경보시스템의 개발 방법에 대한 제안)

  • Shim, Hae-Sup;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.68-76
    • /
    • 2015
  • We examine the standalone lightning warning system (LWS) and its warning performances for three years. This system acquires and analyzes the data of cloud-to-ground strike (CG), intra-cloud discharge (IC) and electrostatic field (EF) to produce prior warnings with respect to the impending arrival of CG in the area of concern (AOC). The warnings in this system are carried out based on the fixed two areas method. To evaluate warning performances, we analyzed the statistics of warnings with probability of detection (POD) and false alarm ratio (FAR). Based on the previous study, we revised the trigger and clear conditions of lightning warning for improving the performances of the system. As a result of this revision, POD increased from 0.18 to 0.44 and FAR decreased from 0.96 to 0.78 during the summer of 2014. However, the LWS was not possible to trigger effective alerts (EA) because there was no effective lead time (LT) for the fixed two areas method. Problems related to the low detection efficiency of IC and the use of EF data for warnings still decreased POD and increased FAR. Hence, we proposed the development method of a new LWS (NLWS) that would be composed of integrated weather data, the flexible two areas and the user software in order to trigger EA and improve warning performances.

A Study on the lightning Discharge Positioning (뇌방전 위치표정에 관한 연구(I))

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Ahn, Chang-Hwan;Lee, Young-Kun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.40-45
    • /
    • 2007
  • Lightning warning system plays an important role in protecting human life and other facilities from lightning return strokes. This paper dealt with lightning positioning algorithms and circuits as a main function of lightning warning system, which monitor movements and activities of thunderclouds. Electric field component produced by lightning discharge is detected by the configuration of a whip antenna and a narrow-band resonance amplifier with center frequency of 300[kHz]. Measurement circuit of magnetic field waveform consists of a crossed-loop coil and an integral amplifier, and its frequency bandwidth is ranges from 5[kHz] to 1.2[MHz]. The polarity of lightning discharge is discriminated by electric field component. After-fixing the polarity, we can calculate the direction and distance of lightning discharge by the peak and the zero-cross time of magnetic field waveform.

A Study on Development of the Lightning Warning System (뇌운경보장치 개발에 관한 연구)

  • Kil Gyung-Suk;Song Jae-Yong;Kim Il-Kwon;Moon Seung-Bo;Cha Myung-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.274-277
    • /
    • 2006
  • This paper describes a lighting warning system (LWS) which consists of a corona needle electrode, a low noise differential amplifier, an A/D converter, an one-chip microprocessor, a LCD and alarm devices. The corona needle electrode is used to measure electric field intensity caused by thunderclouds on the ground level. To evaluate the sensitivity of the LWS, calibration experiment was carried out using a round-shape parallel plate electrode system. The theoretical and experimental results show that the LWS can measure electric field intensity over 2 [kV/m].

  • PDF

Development of a New-Concept Lightning Warning System (신개념 뇌경보 시스템 개발)

  • Choi, Su-Yeon;Park, Chan-Yong;Kil, Gyung-Suk;Ahn, Chang-Hwan;Lee, Young-Kun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.297-300
    • /
    • 2008
  • This paper described a New-Concept lightning warning system (LWS) which can measure electric field intensity on the ground level by an electric field mill (EFM) and calculate the lighting location by radiated electro-magnetic waveform. The EFM measures electric field up to 20[kV/m] with the sensitivity of 0.15[V/kV/m] and frequency bandwidth of the loop antenna was ranges from 5.2[kHz] to 1.71[MHz]. The LWS provides data on the movements of thunderclouds and the possibility of lightning return stroke.

  • PDF

Analysis of administration system for lightning damage in developed countries (선진국의 낙뢰피해 관리운영체제 분석)

  • Cho, Sung-Chul;Lee, Tae-Hyung;Eom, Ju-Hong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.340-343
    • /
    • 2009
  • Recently, the lightning damage to human and structure is increasing steadily and many countries try to reduce lightning-caused casualties and economical loss through special disaster management system. The organization of warning system and management system for lightning damage in developed countries were investigated in this paper. The organization of central government for disaster management and cooperation system with local government in USA, Japan, the Britain, and Germany were introduced and the division of roles with meteorological administration were described.

  • PDF

A Study on the Development of a Lightning Warning System by the Measurement of Electric Field at the Ground (대지전장측정에 의한 뇌경보시스템 개발에 관한 연구)

  • Kil, Gyung-Suk;Lee, Sung-Keun;Song, Jae-Yong;Kim, Jum-Sik;Kwon, Jang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.250-258
    • /
    • 2001
  • In this study, a lightning warning system (LWS) which can predict a lightning return stroke is developed, and the LWS is based on the measurement of electric field intensity at the ground level. The LWS consist of a rotation-type field mill as an electric field sensor, an impedance changer, a two-stage amplifier, and a microprocessor unit. From the calibration experiment, the frequency bandwidth and the maximum resolution of the LWS are $DC{\sim}200\;[Hz]$ and 73 [V/m], respectively. Also, the LWS can measure the electric field strength caused by a thunderstorm up to 18.7 [kV/m] at the ground. To ensure the sensing ability of the developed LWS in an actual situation, computer simulation using thundercloud models was carried out, and the result showed that the LWS can monitor the movement of thunderclouds within 6 [km] from the observation site.

  • PDF

Analysis on Electric Field Based on Three Dimensional Atmospheric Electric Field Apparatus

  • Xing, Hong-yan;He, Gui-xian;Ji, Xin-yuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1697-1704
    • /
    • 2018
  • As a key component of lighting location system (LLS) for lightning warning, the atmospheric electric field measuring is required to have high accuracy. The Conventional methods of the existent electric field measurement meter can only detect the vertical component of the atmospheric electric field, which cannot acquire the realistic electric field in the thunderstorm. This paper proposed a three dimensional (3D) electric field system for atmospheric electric field measurement, which is capable of three orthogonal directions in X, Y, Z, measuring. By analyzing the relationship between the electric field and the relative permittivity of ground surface, the permittivity is calculated, and an efficiency 3D measurement model is derived. On this basis, a three-dimensional electric field sensor and a permittivity sensor are adopted to detect the spatial electric field. Moreover, the elevation and azimuth of the detected target are calculated, which reveal the location information of the target. Experimental results show that the proposed 3D electric field meter has satisfactory sensitivity to the three components of electric field. Additionally, several observation results in the fair and thunderstorm weather have been presented.