• Title/Summary/Keyword: liquid collection method

Search Result 49, Processing Time 0.036 seconds

A Comparison of Collection Concentrations Based on Airborne Toluene Diisocyanates Measurement Methods (공기 중 Toluene diisocyanates 측정방법에 따른 포집농도 비교)

  • Park, Hyung-Sung;Won, Jong-Uk;Kim, Chi-Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.341-347
    • /
    • 2013
  • Objectives: The aim of this study is to investigate the differences in airborne TDI concentrations based on the filter collection method and liquid collection method and to compare airborne TDIs concentrations by sampling method change when using the filter collection method in the spray-painting process. Methods: For the sample measurement, the filter collection method(OSHA#42) and liquid collection method(NIOSH#5522) were used; for the sampling method, the full-period single sampling and full-period consecutive sampling methods were used. The samples were collected in spray-painting and drying process locations. Results: In all samples collected from the spray-painting and drying process locations through the filter collection and liquid collection methods, greater amounts of 2,6-TDI than 2,4-TDI were detected. When the TDI collection concentrations based on the sampling methods were compared, the concentrations of 2,4-TDI and 2,6-TDI collected by the consecutive sampling method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the single sampling method for both the filter collection method and liquid collection method used in the spray-painting process. These differences were statistically significant. Conclusions: When TDI collection concentrations based on the sample measurement methods were compared, the concentration of 2,4-TDI and 2,6-TDI collected through the liquid collection method were higher than the concentrations of 2,4-TDI and 2,6-TDI collected by the filter collection method, and the differences were statistically significant. In the drying process, no difference was shown in the collection concentrations of 2,4-TDI and 2,6-TDI with the two measurement methods.

Improved Accuracy of Cytodiagnosis using the Kato Self-Collection Devise: the Usefulness of Smear Preparation in Liquid-based Cytology Methods

  • Okayama, Kaori;Okodo, Mitsuaki;Fujii, Masahiko;Kumagai, Tomoko;Yabusaki, Hiromi;Shiina, Yoshio;Iwami, Fumihiro;Teruya, Koji;Hatta, Kenmei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4521-4524
    • /
    • 2012
  • Object: In the present study, we compared the positive cytodiagnostic test rates with discrepancies using self-collection devices for cervical cancer screening. We made this survey to examine whether or not our self-smear preparation method using the Kato self-collection device contributed to an improved rate of detecting atypical cells compared with existing recommended preparation methods. Methods: Specimens were collected at 14 facilities handling self-collection methods, and samples were collected by a physician in 2 facilities. The chisquared test was performed using the SPSS ver. 20 statistical software to determine the relationships between the positive cytodiagnostic rate, specimen preparation methods, and self-collection devices. Results: Collecting cells using the Kato self-collection device and preparing liquid-based specimens, we obtained a significantly higher rate of positive cytodiagnosis and our results were equal to those obtained with the direct method. Conclusions: Taking into consideration increased needs for screening using the self-collection method in future, with even more improved test accuracy, a screening test that is acceptable to society needs to be established.

Development of Semicontinuous Measurement System of Ionic Species in PM2.5

  • Hong, Sang-Bum;Chang, Won-il;Kang, Chang-Hee;Lee, Jai H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1505-1515
    • /
    • 2009
  • A new method to semicontinuously determine $PM_{2.5}$ ionic species with a short time resolution is described in detail. In this system, a particle collection section (mixing part, particle collection chamber, and air/liquid separator) was developed. A Y-type connector was used to mix steam and an air sample. The particle collection chamber was constructed in the form of a helix coil and was cooled by a water circulation system. Particle size growth occurred due to the high relative humidity and water absorbed particles were efficiently collected in it. Liquid samples were drained out with a short residence time (0.08-0.1 s). The air/liquid separator was also newly designed to operate efficiently when the flow rate of the air sample was 16.7 L $min^{-1}$. For better performance, the system was optimized for particle collection efficiency with various types of test aerosols such as ($NH_4)_2SO_4,\;NaCl,\;NH_4HSO_4,\;and\;NH_4NO_3$. The particle collection efficiencies were almost 100% at different concentration levels in the range over 500 nm in diameter but 50-90% in the range of 50-500 nm under the following experimental conditions: 15 coil turns, a water flow rate for steam generation of 0.65 mL $min^{-1}$, and an air sample flow rate of 16.7 L $min^{-1}$. Finally, for atmospheric applications, chemical compositions of $PM_{2.5}$ were determined with a time resolution of 20 min on January 11-24, 2006 in Seoul, Korea, and the chemical characteristics of $PM_{2.5}$ ions were investigated.

A Study on the Atomization of a Highly Viscous Biodiesel Oil (고점성 바이오 디젤유의 분무미립화에 관한 연구)

  • 주은선;정석용;강대운;김종천
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.146-153
    • /
    • 1997
  • An experiment was conducted to figure out the atomization characteristics of a highly viscous biodiesel fuel with rice-barn oil applying and ultrasonic energy into it. A spray simulator for the droplet atomization, an ultrasonic system, and six different nozzles(3 pintle-type nozzles and 3 single hole-type nozzles) were made. To investigate effects of ultrasonic energy in a highly viscous liquid fuel, an immersion liquid method was used as a measurement method on droplet size distributions. It was found that the ultrasonic energy was effective for the atomization improvement of the rice-bran oil as a highly viscous biodiesel fuel and the factor나 such as the nozzle opening pressure, pin-edge angles, hole diameters, and collection distances affected the atomization of spray droplets.

  • PDF

Determining Ion Collection Efficiency in a Liquid Ionization Chamber in Co-60 Beam (Co-60 빔에서 액체 전리함의 이온 수집 효율 결정 연구)

  • Choi, Sang Hyoun;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • Liquid ionization chamber is filled with liquid equivalent material unlike air filled ionization chamber. The high density material allow very small-volume chamber to be constructed that still have a sufficiently high sensitivity. However liquid ionization chamber should be considered for both initial recombination and general recombination. We, therefore, studied using the Co-60 beam as the continuous beam and the microLion chamber (PTW) for comparing the ion collection efficiency by Greening theory, two-dose rate method and our experiment method. The measurements were carried out using Theratron 780 as the cobalt machine and water phantom and 0.6 cc Farmer type ionization chamber was used with microLion chamber in same condition for measuring the charge of microLion chamber according to the dose rates. Dose rate was in 0.125~0.746 Gy/min and voltages applied to the microLion chamber were +400, +600 and +800 V. As the result, the collection efficiency by three method was generally less than 1%. In particular, our experimental collection efficiency was in good agreement within 0.3% with Greening theory except the lowest two dose rates. The collection efficiency by two-dose rate method also agreed with Greening theory generally less than 1%, but the difference was about 4% when the difference of two dose rates were lower. The ion recombination correction factors by Greening theory, two-dose rate method and our experiment were 1.0233, 1.0239 and 1.0316, respectively, in SSD 80 cm, depth 5 cm recommended by TRS-398 protocol. Therefore we confirmed that the loss by ion recombination was about 3% in this condition. We think that our experiment method for ion recombination correction will be useful tool for radiation dosimetry in continuous beam.

Maintenance of Filamentous Fungi in Korean Agricultural Culture Collection (KACC) (농업미생물은행(KACC)의 곰팡이 보존)

  • Shin, Myeong-Suk;Hong, Seung-Beom
    • The Korean Journal of Mycology
    • /
    • v.42 no.2
    • /
    • pp.97-103
    • /
    • 2014
  • A total of 7039 strains of filamentous fungi are preserved in Korean Agricultural Culture Collection (KACC). The 4065 strains (58%) of them, which produce many spores in cultivation on proper media, are preserved with freeze-drying method. They are also preserved with liquid nitrogen and deep-freezer storage in order to minimize loss by death. Aspergillus, Penicillium, Lichtheimia, Mucor, Rhizopus, etc. which are common in surrounding environments, are included in this category. The others which do not produce spores, or produce few spores in vitro, are preserved with liquid nitrogen, deep-freezer and mineral oil storage. Phytophthora, Pythium, Cercospora, Septoria, Rhizoctonia, etc. are included in this category. The authors also introduced various fungal preservation methods and provided detailed preservation procedures that are used in KACC.

Design and Performance Evaluation using Computational Fluid Dynamics (CFD) Analysis of Wetcyclones for the Collection of Airborne Bacteria (공기 중 박테리아 포집을 위한 습식 사이클론의 CFD 해석을 이용한 설계 및 성능 평가)

  • Hyun Sik Ko;Jungwoo Park;Jiwoo Jung;Jungho Hwang
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.77-87
    • /
    • 2023
  • We present the development of a wetcyclone sampler designed for the sampling of airborne bacteria. The wetcyclone design involves a combination of two traditional cyclone shapes and computational fluid dynamics (CFD) analysis to validate its effectiveness in terms of pressure drop and collection efficiency. The wetcyclone exhibits a collection efficiency of over 90% for bacteria, specifically targeting Staphylococcus aureus. Additionally, the wetcyclone enables continuous bioaerosol sampling using a liquid medium (deionized water), demonstrating a concentration ratio exceeding >105 and a stable microbial recovery rate of 81.9%. The application of real-time quantitative polymerase chain reaction (qPCR) and the colony counting method ensures precise measurement of the concentration ratio and microbial recovery rate.

Fabrication of Beta-phase Poly(9,9-dioctylfluorene) Nanowire Arrays for Polymer Light-Emitting Diode Using Direct Printing Method

  • Baek, Jang-Mi;Lee, Gi-Seok;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.560-560
    • /
    • 2012
  • We report a one-step fabrication method of Poly(9,9-dioctylfluorene) (PFO) nanowire array with pronounced ${\beta}$-Phase. We use liquid-bridge-mediated nanotransfer molding (LB-nTM) which is a new direct nano-patterning method based on the direct transfer of various materials from a mold to a substrate via liquid layer. The formation of the ${\beta}$-phase morphology in the resulting PFO nanowire array was evidenced by the presence of an absorption peak at 435nm. With the collection polarizer oriented parallel to the wire long axis, the PL emission was most intense and an emission dichroic ratio, DRE, of 3.7 was determined. The nanowire array have been investigated by scanning electron microscopy (SEM). Also, we simply fabricated structure of device of ITO/PFO nanowire arrays/Al and the electroluminescence spectra were recorded at various applied voltage.

  • PDF

Use of Ultrasonic to Atomizing a Highly Viscous Bio-oil (고점성 바이오유의 분무미립화를 위한 초음파 이용)

  • 주은선;나우정;김종천
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.467-473
    • /
    • 1996
  • Ultrasonic energy was applied for atomizing rice-bran oil which is a highly viscous bio fuel. Six different nozzles, an injection simulator, and an ultrasonic generator system were designed and constructed for the experiment. An immersion liquid method was used for the measurement of injection droplet sizes. The characteristics of injection droplets was investigated with respect to the numbers of the droplets with diameters ranging from 5$\mu$m 50$\mu$m and to the Sauter mean diameter. The results showed that the ultrasonic energy was effective for the improvement of the atomization of the injection droplets for all the factors such as type of nozzles, nozzle opening pressures, and collection distances.

  • PDF

A Correction Method for Operating Mode Analysis of Gas Generator Cycle Liquid Propellant Rocket Engine (가스발생기 사이클 액체로켓엔진작동 모드 해석의 보정 방법)

  • Nam, Chang-Ho;Moon, Yoonwan;Park, Soon Young;Chung, Enhwan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.104-110
    • /
    • 2018
  • Operating mode analysis of a liquid propellant rocket engine(LRE) is a crucial tool through the development of an engine. The operating mode analysis of an engine based on a collection of the acceptance tests of components shows discrepancies when compared to the test results. We propose a correction method for performance parameters to develop an engine analysis model for the gas generator cycle of an LRE. In order to simulate engine behavior, the performance parameters for the analysis model are tuned based on the test results of the 75tf engine of KSLV-II.