• 제목/요약/키워드: loading speed

검색결과 719건 처리시간 0.03초

고속 컨테이너 하역시스템의 하역방법에 관한 연구 (A Study on Loading/Unloading Methods for High-Speed Container Loading/Unloading System)

  • 박경택;김선호;김두형
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 추계학술대회논문집:21세기에 대비한 지능형 통합항만관리
    • /
    • pp.167-174
    • /
    • 1998
  • Recently several researches of high speed container ship and loading system are mainly accomplished in U.S.A. and Japan. Its shipping service is not realized but it is realized in near future. To effective use of the feature and efficiency of them, quay, loading/unloading. yard operation system, port management system and connection transport system must be well integrated and operated. Specially, loading /unloading speed of container crane is important for making effective use of them. To speed up loading/unloading system, RO-RO and LO-LO methods that are mostly exclusive system are studied on the container crane with special structure and mechanism to handle individual container or bundle of containers. In this paper these methods are shown. When new high speed loading system of container is desighed, the realistic constrains must be considered.

  • PDF

아스팔트 콘크리트 변형강도 시험에서의 적정 하중재하속도 선정 연구 (Determination of Proper Loading Speed for Deformation Strength Test of Asphalt Concretes)

  • 조병진;박태원;도영수;김광우
    • 한국도로학회논문집
    • /
    • 제10권4호
    • /
    • pp.225-234
    • /
    • 2008
  • 본 연구는 아스팔트 혼합물의 변형강도에 대한 적정 하중재하속도를 선정하기 위하여 수행하였다. 이를 위하석 직경(D) 40mm, 하단의 원형 절삭반경(r)을 10.0mm의 하중봉으로 Kim test의 하중재하속도를 분당 10mm, 30mm, 50mm, 70mm로 하여 변형강도를 측정하고 반복주행시험을 수행하여 얻어진 소성변형 특성치와의 상관관계에 대하여 회귀분석을 수행하였다. 하중재하속도별 변형강도 값은 하중재하속도가 증가함에 따라 변형강도도 증가하는 경향을 보였다. 이것은 하중재하속도가 변형강도에 미치는 영향이 큰 요소임을 알 수 있었다. 하중재하속도에 따른 변형강도와 반복주행시험 결과인 최종침하깊이 및 동적안정도와의 상관성 분석을 통해 30mm/min의 하중재하속도가 가장 적합한 것으로 나타났다. 하중 30mm/min 하중재하속도가 불가능한 시험기의 30mm/min 하중재하속도에서의 변형강도는 제안된 환산계수를 적용해야 한다.

  • PDF

Performance of Rotating Biological Contactor (RBC) under Different Hydraulic Loading Rates and Rotational Speeds on Ammonia Removal in a Recirculating System

  • Son Maeng Hyun;Jeon Im Gi;Jo Jae-Yoon;Moon HaeYoung
    • Fisheries and Aquatic Sciences
    • /
    • 제2권1호
    • /
    • pp.52-57
    • /
    • 1999
  • Air-drived rotating biological contactor (RBC) system, which is effective method in filtering performance, was tested for the nitrification capacity in a recirculating system. At ammonia concentrations between 0.029 and 0.528 mg/l, the effect of ammonia loading rate on ammonia removal rate at three different hydraulic loading rates could be defined by the following first­order regression models: Hydraulic loading rate of $14.8 m^3/m^3/day:\;y=39.2\times+3.4 (r^2=0.9137)$, Hydraulic loading rate of $26.5 m^3/m^3/day: y=53.3\times+4.0 (r^2=0.8686)$, Hydraulic loading rate of $37.3 m^3/m^3/day: y=58.4\times+4.2 (r^2=0.7755)$, where, $\times$ is ammonia loading rate (mg/l), y is ammonia removal rate $(g/m^3/day)$, The equations showed the optimal ammonia removal rate at the hydraulic loading rate of $26.5m^3/m^3/day$. Below the ammonia concentration of 2.72 mg/l, first-order regression models between ammonia loading rate and ammonia removal rate at three different rates of speed are defined as follows: Rotational speed of $0.75 rpm: y=28.5\times+4.7 (r^2=0.9143)$, Rotational speed of $1.0 rpm: y=33.6\times+8.4 (r^2=0.9534)$, Rotational speed of $2.0 rpm: y=28.9\times+3.6 (r^2=0.9488)$, where, x is ammonia loading rate (mg/l), y is ammonia removal rate $(g/m^3day)$. The equations show the ammonia removal rate at the rotational speed of 1.0 rpm is significantly higher than that at the rotational speed of either 0.75 rpm or 2.0 rpm (P<0.05).

  • PDF

A Study on Fluctuating Pressure Load on High Speed Train Passing through Tunnels

  • Seo Sung-Il;Park Choon-Soo;Min Oak-Key
    • Journal of Mechanical Science and Technology
    • /
    • 제20권4호
    • /
    • pp.482-493
    • /
    • 2006
  • The carbody structure of a high speed train passing through a tunnel is subjected to pressure fluctuation. Fatigue strength of the carbody structure against the fluctuating pressure loading should be proved in the design stage for safety. In this study, to get the useful information on the pressure fluctuation in the tunnel, measurement has been conducted during test running of KHST on the high speed line for two years. The measured results were analyzed and arranged to be used for carbody design. A prediction method for the magnitude and frequency of pressure change was proposed and the propagating characteristics of pressure wave was investigated. By statistical analysis for the measured results, a pressure loading spectrum for the high speed train was given. The proposed method can also be used to estimate the pressure loading spectrum for new high speed line at design stage combined with the results of train performance simulation.

SOIL FAILURE AND ITS APPLICATION TO VIBRATING TILLAGE TOOL

  • Niyamapa, Tanya
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.1053-1062
    • /
    • 1993
  • The effect of loading speed on soil failure was studied by using a high speed triaxial compression test. Tests were conducted at 0.35-6.2m/s loading speed to compress soil specimens of sandy loam at different moisture contents. The axial stress at fracture increased with increase in loading speed up to certain critical speeds, however they decreased as the speed up to certain critical speeds, however they decreased as the speed increased further. Experiments were also conducted in the field of sandy loam soil with the vibrating tillage tool. Tests were done at 0.33-0.85m/s tractor speed oscillating frequency 13.7hz and oscillating amplitude 59mm. The maximum oscillating velocity of tillage tool was 2.5m/s. It was observed that for the oscillating operation, initially draft slightly increased with increase in forward speed and then it decreased .For the non-oscillating operation, draft increased continuously with increase in forward speed. Approach of studying soil failure in the laboratory test can be related to the field experiments.

  • PDF

Study on seismic performance of exterior reinforced concrete beam-column joint under variable loading speeds or axial forces

  • Guoxi Fan;Wantong Xiang;Debin Wang;Zichen Dou;Xiaocheng Tang
    • Earthquakes and Structures
    • /
    • 제26권1호
    • /
    • pp.31-48
    • /
    • 2024
  • In order to get a better understanding of seismic performance of exterior beam-column joint, reciprocating loading tests with variable loading speeds or axial forces were carried out. The main findings indicate that only few cracks exist on the surface of the joint core area, while the plastic hinge region at the beam end is seriously damaged. The damage of the specimen is more serious with the increase of the upper limit of variable axial force. The deflection ductility coefficient of specimen decreases to various degrees after the upper limit of variable axial force increases. In addition, the higher the loading speed is, the lower the deflection ductility coefficient of the specimen is. The stiffness of the specimen decreases as the upper limit of variable axial force or the loading speed increase. Compared to the influence of variable axial force, the influence of the loading speed on the stiffness degradation of the specimen is more obvious. The cumulative energy dissipation and the equivalent viscous damping coefficient of specimen decrease with the increase of loading speed. The influence of variable axial force on the energy dissipation of specimen varies under different loading speeds. Based on the truss model, the biaxial stress criterion, the Rankine criterion, the Kent-Scott-Park model, the equivalent theorem of shearing stress, the softened strut-and-tie model, the controlled slip theory and the proposed equations, a calculation method for the shear capacity is proposed with satisfactory prediction results.

Modulus degradation of concrete exposed to compressive fatigue loading: Insights from lab testing

  • Song, Zhengyang;Konietzky, Heinz;Cai, Xin
    • Structural Engineering and Mechanics
    • /
    • 제78권3호
    • /
    • pp.281-296
    • /
    • 2021
  • This article analyzed the modulus degradation of concrete subjected to multi-level compressive cyclic loading. The evolution of secant elastic modulus is investigated based on measurements from top loading platen and LVDT in the middle part of concrete. The difference value of the two secant elastic moduli is reduced when close to failure and could be used as a fatigue failure precursor. The fatigue hardening is observed for concrete during cyclic loading. When the maximum stress is smaller the fatigue hardening is more obvious. The slight increase of maximum stress will lead to the "periodic hardening". The tangent elastic modulus shows a specific "bowknot" shape during cyclic loading, which can characterize the hysteresis of stress-strain and is influenced by the cyclic loading stresses. The deterioration of secant elastic modulus acts a similar role with respect to the P-wave speed during cyclic loading, can both characterize the degradation of the concrete properties.

사전균열로 손상된 RC 보의 탄소섬유시트 보수 후의 균열성장 및 박락거동 (Crack Growth and Debonding Behaviors of the Pre-cracked RC Beams Repaired with Carbon Fiber Sheets)

  • 김충호;고신웅
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권5호
    • /
    • pp.121-129
    • /
    • 2006
  • 본 연구는 균열이 발생한 R/C보를 탄소섬유시트(Carbon fiber sheet)로 보수했을 경우 시트의 박락과 균열의 확대 및 성장 메커니즘을 조사한 것이다. 실험변수는 하중형식, 재하속도, 사전균열 유무 등이다. 실험에서, 보의 파괴는 전단력 급변에 의한 재하점 직하부의 단차박리의 발전과 전파로 시작됨이 확인되었지만, 파괴기구는 하중형식, 재하속도, 사전균열 유무 등에 영향을 받지 않았다. 특히, 사전균열을 갖는 보의 경우, 균열의 성장은 재하점 직하의 특정한 균열에 집중되고, 이 균열의 확장에 의한 탈착이 보의 파괴를 이끌었다.

MAS(Moving Autoblock System) 방법을 이용한 한국형 고속전철의 선로 효율 분석 (Analysis of loading capacity of Korean High-Speed Train by using MAS(Moving Autoblock System) method)

  • 정판규;이재덕;이주훈;조창희;김국헌;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1426-1428
    • /
    • 2000
  • A new block system - MAS (Moving Autoblock System) whose efficiency is higher than FAS(Fixed Autoblock System) in the loading capacity is required to accomodate the increasing transport volume. That MAS has higher efficiency has already been verified through various studies, especially in a line with different types of travelling trains. The efficiency of MAS for Korean high speed line with two different train model is analyzed by computer simulation. The results show that MAS is more efficient than FAS in the loading capacity.

  • PDF

점용접부에서 하중속도효과를 고려한 피로수명평가 (Fatigue Life Evaluation of Spot Welding Including Loading Speed Effect)

  • 양성모;강희용;김홍진;송준혁
    • 한국공작기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.32-37
    • /
    • 2003
  • Evaluation of fatigue strength on the spot welded part is very important for strength design of spot welded steel structures. In this paper, we could get the life cycle of the spot welded part using the lethargy coefficient obtained through the quasi-static tensile shear test for the specimen welded by current 10kA. The reliability evaluation of the life cycle is completed by comparing the life cycle calculated under the constant loading rate with the life cycle obtained by dynamic fatigue test. And then the result calculated by the lethargy coefficient is verified through the lift cycle calculated using the dynamic final tensile stress formula under the increased loading speed. This way can make save the time and cost in processing of predicting the life cycle of a structure.