• Title/Summary/Keyword: low level correction

Search Result 119, Processing Time 0.033 seconds

Application of Pressure Correction Method to CFD Work for 8 Centrifugal Compressor Impellers (압력보정법을 이용한 8개의 원심압축기 임펠러 CFD의 적용 연구)

  • Oh, Jongsik;Ro, SooHyuk;Hyun, YongIk
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.226-235
    • /
    • 2000
  • Two representative finite volume methods, i.e., the time marching method and the pressure correction method, were applied to 8 centrifugal compressor impeller flows, with low to very high level of pressure ratio, among which 7 impellers' experimental performance is given in the open literature. The present study is focused on the prediction differences from both methods, developed by the authors, in the pressure correction method's point of view. In all cases, the time marching method gives a satifactory solution, but the pressure correction method does not. Up to about $18\%$ less level of total-to-total pressure ratio is predicted by the pressure correction method as the level of the impeller pressure ratio increases up to about 10. The drop of total pressure ratio is caused by the underestimation of static pressure rise which seems to be attributed to inappropriate linearization and discretization of the pressure/density coupling terms in the pressure correction equation.

  • PDF

Period of the Strength Correction of the Concrete with the Temperature Level Based on Meteorological Data (기상자료를 이용한 콘크리트의 단계별 기온보정강도 적응기간 산정)

  • Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 2008
  • According to Korean Architectural Standard Specification (KASS) , at the design stage of the specified concrete strength, strength correction with each temperature level should be considered to secure required strength at 28 days even in low temperature condition, In this paper, the period for the strength correction at the stage of mixture design of the concrete using ordinary Portland cement(OPC) specified in KASS was determined with each region of south Korea based on the meteorological data of KMA(Korea meteorological administration) by applying KASS-5 regulation. In case of 28 days of strength control age, the period for strength correction with 6MPa was calculated to $50{\sim}60$ days and, with 3 MPa. to around 80 days. The period for the strength correction was shown to be decreased with the rise of altitude. The period to consider the delay of the strength development due to low temperature including the period of cold weather concrete was nearly 7 months around 1 year. References for determining the strength correction factors with each region of south Korea was provided in this paper. Further investigation of strength correction of the concrete containing blended cement is to studied.

Fast Correction of Nonuniform Illumination on Bi-level Images using Block Based Intensity Normalization (블록 기반 밝기 표준화를 통한 이진영상의 고속 불균일 조명 보정)

  • Joung, Ji-Hye;Kim, Jeong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1926-1931
    • /
    • 2012
  • We investigated a novel fast non-uniform illumination correction method for bi-level images. The proposed method divides a bi-level image into sub-images and roughly estimates block-wise illumination by low pass filtered maximum values of sub-images. After that, we apply bilinear interpolation using the block-wise illumination to estimate non-uniform illumination, and compensate for the effect of non-uniform illumination using the estimated illumination. Since the proposed method is not based on computation intensive iterative optimization, the proposed method can be used effectively for applications that require fast correction of non-uniform illumination. In simulations, the proposed method showed more than 20 times faster speed than existing entropy minimization method. Moreover, in simulations and experiments, the restored images by the proposed method were more close to true images than images restored by conventional method.

Ricean Bias Correction in Linear Polarization Observation

  • Sohn, Bong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.267-271
    • /
    • 2011
  • I developed an enhanced correction method for Ricean bias which occurs in linear polarization measurement. Two known methods for Ricean bias correction are reviewed. In low signal-to-noise area, the method based on the mode of the equation gives better representation of the fractional polarization. But a caution should be given that the accurate estimation of noise level, i.e. ${\sigma}$ of the polarized flux, is important. The maximum likelihood method is better choice for high signal-to-noise area. I suggest a hybrid method which uses the mode of the equation at the low signal-to-noise area and takes the maximum likelihood method at the high signal-to-noise area. A modified correction coefficient for the mode solution is proposed. The impact on the depolarization measure analysis is discussed.

Power Factor Improvement of Single-Phase Three-level Boost Converter (단상 Three-level boost converter의 역률개선)

  • 서영조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.384-387
    • /
    • 2000
  • In this paper Power factor correction circuit of single-phase three-level boost converter is proposed. The advantage of the proposed control scheme for three-level boost converter are low blocking voltage of each power device low THD(Total Harmonic Distortion) and high power factor. The control scheme is based on the current comparator capacitor compensator and region detector, In simulations the proposed system is validated.

  • PDF

Correction Method for Signal Boost-up or Drag-down Caused by Non-zero Mean Noise (Non-zero Mean Noise에 의한 Signal의 Boost-up 및 Drag-down을 Correction하기 위한 연구)

  • Im, Na-Ri;Kim, Il-Do;Choi, Byung-Sun;Park, Sahng-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.229-230
    • /
    • 2007
  • 카메라 시스템에서 일반적인 Noise Reduction방법은 Noise간에 서로 Correlation이 없고 Independent한 White Noise이며, Zero Mean Noise라는 가정 하에 설계된 것이다. 본 논문에서는, 실제 Non-zero Mean Noise 현상을 규명하고, 이에 의해 발생한 Low Level Signal의 Boost-up 및 High Level Signal의 Drag-down을 Correction하여 화질을 개선하기 위한 방안을 제안한다.

  • PDF

A Study on the Economical Design of Low-Voltae feeder Considering the temperature character (온도특성을 고려한 저압간선의 경제적인 설계기법에 관한 연구)

  • 최홍규;조계술
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.349-354
    • /
    • 2002
  • A size of low-voltage conductor cables is determined by the voltage drop of a system, the cable impedance and the cable ampacity based on temperature correction factor in accordance with the condition of cable installation. Therefore, the proper temperature correction factor according to the condition of cable installation should be applied to determining the cable ampacity and also the skin effect and proximity effect, along with the kind and size of conductor and the condition of cable installation, should be properly considered to analyze the proper value of resistance and the reactance of the conductors. This paper addresses the systematic design flow for determining the size of low voltage level conductor cables in calculating the temperature character where error should be minimized in comparison with the general formula and which can be applied in design work for determining the size of conductor cables.

  • PDF

A Joint Sub-Packet Level Network Coding and Channel Coding (서브 패킷 단위의 네트워크 코딩 및 채널 코딩 결합 기법)

  • Kim, Seong-Yeon;Shin, Jitae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.4
    • /
    • pp.659-665
    • /
    • 2015
  • Recent studies on network coding scheme for increasing transmission efficiency of the network has been actively conducted. In this paper, we apply RLNC in sub-packet unit and propose a joint scheme of sub-packet level network coding and LDPC code. The proposed method can have similar ability of network coding and obtain further error correction capability. The simulation results show that the proposed one enhances error correction capability compared to the case using only LDPC when extra packets are received.

Integrated Boost-Flyback ZCS Quasi-Resonant Power Factor Preregulator (부스트-플라이백 결합형 ZCS Quasi-Resonant 역률개선 컨버터)

  • 이준영;문건우;김현수;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.91-98
    • /
    • 1999
  • An integrated ZCS quasi-resonant converter(QRC) for the power factor correction with a single switch is presented in this paper. The power factor correction can be achieved by the discontinuous conduction mode(DCM) operation of the input current. The proposed converter gives the good power factor, low line current harmonics, and tight output regulation. The input current waveform of the prototype designed using design equations shows about 15% of total harmonic distortion at rated condition. Also, the efficiency and power factor can be obtained about 86% and 0.985, respectively, at rated condition. The proposed converter is suitable for a low power level converter with a tightly regulated low output voltage and switching frequency of more than several hundreds kHz.

  • PDF

Determination of the Strength Correction with the Temperature Level in Each Region of Korea (우리나라 각 지역의 단계별 기온보정강도 적용기간 설정)

  • Baek, Dae-Hyun;Kim, Sung-Il;Kim, Jung-Jin;Lee, Gun-Cheol;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.19-23
    • /
    • 2007
  • In this paper, the period for the strength correction was determined with each region of south Korea based on the meteorological data of KMA(Korea meteorological administration) by applying KASS-5 regulation. In case of 28 days of strength control age, the period for strength correction with 6MPa was calculated to 50-60 days and, with 3 MPa. to around 80 days. The period for the strength correction was shown to be decreased with the rise of altitude. The period to consider the delay of the strength development due to low temperature including the period of cold weather concrete was nearly 7 months around 1 year. References for determining the strength correction factors with each region of south Korea was provided in this paper.

  • PDF