• Title/Summary/Keyword: low smoke

Search Result 307, Processing Time 0.032 seconds

The Influence on the Stack Effect with the Opening of Smoke Ventilators in High-rise Buildings (초고층 건축물에서 배연창 개방이 연돌효과에 미치는 영향)

  • Lim, Chae-Hyun;Kim, Bum-Gyue;Yeo, Yong-Ju;Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.209-213
    • /
    • 2008
  • The effects on the performance of natural smoke exhaust ventilators installed in high-rise buildings were analyzed depending on the wind velocities and smoke temperatures using CONTAMW tool. The results showed that the smoke exhaust ventilators can maintain given performances in such conditions as low smoke temperatures and low wind velocities. However, high smoke temperatures and high wind velocities can prevent the smoke ventilators to exhaust smokes from the fire room. Significant changes in stack effects in high-rise buildings can also occur with the opening of smoke ventilators in the fire floor.

  • PDF

A Study on the Development of a Low-cost Device for Measuring the Optical Smoke Density (광학적 연기밀도 측정을 위한 저가형 장치의 개발에 관한 연구)

  • Kim, Bong-Jun;Cho, Jae-Ho;Hwang, Cheol-Hong;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.81-88
    • /
    • 2015
  • A low-cost device using the light-extinction method was developed to measure the optical smoke density in various fire experiments in the present study. The relative measurement accuracy of low-cost device was evaluated through the comparison of optical density measured by a high-cost standard device consisting of He-Ne laser, photo detector and various optical components. The low-cost device was composed of laser module, photocell and acrylic board. From the experiments using a smoke generator can be easily adjusted the smoke concentration, it was found that the low-cost device could measure the smoke density within the range of ${\pm}10%$, compared to the standard device. In addition, the reliability of low-cost device was also confirmed in the experiment using a polyethylene flame. Finally, it is expected that the low-cost device developed with real-time measurement and simple installation for measuring the smoke density will be used instead of the high-cost standard device.

Study on Halogen Free Low Smoke Polyolefin (할로겐이 없는 저연성 폴리올레핀에 관한 연구)

  • Kim, Young-Doo;Chung, Kwang-Soo;Kim, Tae-Ho
    • Elastomers and Composites
    • /
    • v.37 no.3
    • /
    • pp.177-182
    • /
    • 2002
  • For low-smoke-type polyolefin compound, LDPE, EVA, and EEA as base resin, magnesium trihydrate, alumina trihydrate, and red phosphorous as flame retardant and MAH type compatibilizer were applied. The amount of each component was changed to find out optimum composition. Mechanical properties were obtained by tensile test and residual stress after aging and flame retardancy was evaluated by smoke density, LOI(Limit Oxygen Index), and UL-94 test. SEM was used for the investigation or morphology and halogen contents were obtained by measuring the amount of HCI. Two kinds of halogen free compositions for flame retardant and low smote resin were found and it is expected to be applied for various purposes.

Video smoke detection with block DNCNN and visual change image

  • Liu, Tong;Cheng, Jianghua;Yuan, Zhimin;Hua, Honghu;Zhao, Kangcheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.9
    • /
    • pp.3712-3729
    • /
    • 2020
  • Smoke detection is helpful for early fire detection. With its large coverage area and low cost, vision-based smoke detection technology is the main research direction of outdoor smoke detection. We propose a two-stage smoke detection method combined with block Deep Normalization and Convolutional Neural Network (DNCNN) and visual change image. In the first stage, each suspected smoke region is detected from each frame of the images by using block DNCNN. According to the physical characteristics of smoke diffusion, a concept of visual change image is put forward in this paper, which is constructed by the video motion change state of the suspected smoke regions, and can describe the physical diffusion characteristics of smoke in the time and space domains. In the second stage, the Support Vector Machine (SVM) classifier is used to classify the Histogram of Oriented Gradients (HOG) features of visual change images of the suspected smoke regions, in this way to reduce the false alarm caused by the smoke-like objects such as cloud and fog. Simulation experiments are carried out on two public datasets of smoke. Results show that the accuracy and recall rate of smoke detection are high, and the false alarm rate is much lower than that of other comparison methods.

A Study on Smoke Movement by Using Large Eddy Simulation II. Smoke Control Systems and Opening Size (대와류모사를 이용한 연기이동의 연구 II. 제연방식과 개구부의 크기)

  • 박외철
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.34-38
    • /
    • 2003
  • The large eddy simulation based Fire Dynamics Simulator was utilized to investigate the effects of the size of an opening on smoke removal performance for the three smoke control systems-ventilation purge, and extraction. Three different opening sizes, $r_A$=1, 2, and 3 were investigated while the flow rate remained 0.75 $m^3/s$ at the inlet or outlet depending on the systems. Increase of the opening size did not give a significant difference in the smoke removal rate for the three smoke control systems, though the increasing opening size slightly improved smoke removal. The extraction system was shown the best smoke control system, and the purge system yielded low performance compared to the other two systems for all the different opening sizes.

Changes of Smoke Components with Stalk Position and Grade of Korean Leaf Tobacco (국내 원료잎담배의 착엽위치 및 가공등급에 따른 연기성분 변화)

  • 황건중;이문수
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.24 no.1
    • /
    • pp.38-45
    • /
    • 2002
  • This study was conducted to determine the smoke component concentration and the smoke distribution in the cambridge filter pad and cigarette filter with stalk position and grade of Korean leaf tobaccos. 12 grades of flue-cured and burley leaf tobaccos which were taken from the Kim-cheon and Ock-cheon leaf tobacco processing factory were used for this study. Six kinds of smoke components such as tar, nicotine, water, carbon monoxide(CO), carbon dioxide($CO_2$) puff No. collected in the cambridge filter pad and cigarette filter were analyzed. Also, nicotine/tar, CO/tar ratio were calculated from the analytical data. Puff no., CO, and $CO_2$ concentration of flue-cured and burley tobacco leaves at high stalk position were higher than those of low stalk position, and these components were increased in high grade of leaf tobacco. Compared with flue-cured tobacco, burley tobacco showed a little values of puff no., nicotine, and tar concentration. The pH range of burley tobaccos was broader than that of flue-cured tobaccos, and the ammonia concentration of burley tobaccos was significantly higher than that of flue-cured tobaccos. The pH value and ammonia concentration of burley tobaccos were decreased as stalk position of leaf tobaccos decreased. The distribution of smoke components collected in the cambridge filter pad and cigarette filter was different with a different grade and stalk position of tobacco leaves. In high stalk position of tobacco leaves, the portion of smoke components collected in the cambridge filter pad was also increased. The average nicotine, water, and tar removal efficiency by a cigarette filter in a flue-cured tobacco were 37%, 64%, and 48%, respectively. Compared with flue-cured tobaccos, smoke components of burley tobaccos had high nicotine and low water removal efficiency by a cigarette filter. The average ratio of nicotine/tar and CO/tar of flue-cured tobaccos and burley tobaccos were 0.097, 1.22, 0.094, and 0.97, in order. Nicotine/tar ratio was decreased and CO/tar ratio was increased in low stalk position.

Algorithm for Detection of Fire Smoke in a Video Based on Wavelet Energy Slope Fitting

  • Zhang, Yi;Wang, Haifeng;Fan, Xin
    • Journal of Information Processing Systems
    • /
    • v.16 no.3
    • /
    • pp.557-571
    • /
    • 2020
  • The existing methods for detection of fire smoke in a video easily lead to misjudgment of cloud, fog and moving distractors, such as a moving person, a moving vehicle and other non-smoke moving objects. Therefore, an algorithm for detection of fire smoke in a video based on wavelet energy slope fitting is proposed in this paper. The change in wavelet energy of the moving target foreground is used as the basis, and a time window of 40 continuous frames is set to fit the wavelet energy slope of the suspected area in every 20 frames, thus establishing a wavelet-energy-based smoke judgment criterion. The experimental data show that the algorithm described in this paper not only can detect smoke more quickly and more accurately, but also can effectively avoid the distraction of cloud, fog and moving object and prevent false alarm.

A Study on Performance Characteristics of the Diesel Engine using High Viscous Oils by blending Low Boiling Point Oxygenates (저비점 함산소물질 혼합에 의한 고점도유 사용 디젤기관의 성능특성 연구)

  • ;Noboru Miyamoto
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.4
    • /
    • pp.44-51
    • /
    • 2003
  • By blending of various low boiling point oxygenated agents to lower grade fuels, significant improvements were simultaneously obtained in smoke, CO, PM, SOF and BSEC. Especially, our trends were remarkably obtained by retarding injection timing, by decreasing boiling point and increasing blending contents of additives in case of oxygenated agents rather than non-oxygenated agents. Also, it was revealed that when 20vo1.% DMM added to high viscosity fuels and injection timing was retarded, NOx-smoke trade off relationship was much better than that of ordinary diesel fuel. Thus, lower grade fuels with high viscosity could be expected to be used efficiently and cleanly in diesel operation by blending low boiling point oxygenates.

Development of a precision smoke particle detector to sense a fire in early state (초기화재 감지를 위한 정밀한 연기 입자 감지 장치 개발)

  • 김희식;김영재;이호재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1734-1737
    • /
    • 1997
  • The conventional fire detection devices are operated after a processed fire phase, which are sensing only a high density of somke level or high temperature heat. They are not so precision to detect a fire in the early phase to protect the facility form the fire. We need to develope a new high precision smoke detection system to keep expensive industrial facilities most reliably form fire. A new optical precision smoke detection system was developed. It monitors very low level density of smoke particles in the air. It is operated continously through many years without a stop or any malfunction. The developed precision smoke detection system will be installed in important industrial facilities, such as power plants, underground common tunnel, main control rooms, computer rooms etc.

  • PDF

연기농도 계측용 광학식 미세입자 감지장치 개발

  • 김영재;김희식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.128-132
    • /
    • 1997
  • The conventional fire detection devices are operated after a processed fire phase, which are sensing only a high density of smoke level or high temperature heat. They are not so precision to detect a fire in the early phase to protect the facility from the fire. We need to develope a new high precision smoke detection system to keep expensive industial facilities most reliably from fire. A new optical precision smoke detection system was developed. It monitors very low level density of smoke psrticles in the air. It is operated continuously through many years without a stop or any malfunction. The developed precision smoke detection system will be installed in important industrial facilities,such as power plants, underground common tunnel,main control rooms,computer rooms etc.

  • PDF