• Title/Summary/Keyword: magnetic field shields

Search Result 8, Processing Time 0.03 seconds

A study on the electrostatic and magnetic flux cut off effect using anti-magnetic material (반자성 물질에 의한 전자기차단효과에 관한 연구)

  • Hwang, Yoon-Taek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.8
    • /
    • pp.1473-1480
    • /
    • 2008
  • Bisumus has a low melting point, making it easier to handle. This allows us to test what type of effect diamagnetism has on electro static and magnetic field shields. However, the actual materials for experimentation have only ever been manufactured cylindrically, and so there have been no recorded cases of measurements to this effect. To understand what kind of effect pure bisumus as diamagnetism has on electro static and magnetic shields in comparison to other materials, bisumus, along with copper, aluminum and iron 스텐도, were used to make a cylinder each. These cylinders were then used to measure and compare the electro static shield and magnetic shield at different bands of frequencies, starting from a low frequency. As shown on the graph/chart/diagram, the best results were recorded for copper and bisumus as diamagnetism in an electro static field. In terms of magnetic shielding, iron provided the best results, as expected, whereas bisumus displayed minimal effect.

Magnetic-Shielding Effectiveness Analysis of the Trigger Assembly of Small Arms (소구경 개인화기 격발신호 발생장치의 자기차폐효과 분석)

  • Lee, Kisu;Ahn, Joon Mo;Chae, Je-Wook
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.456-463
    • /
    • 2018
  • With the development of weapon systems by mounting various sensors, it makes important to analyze the precise functioning of sensor to external environment. In the case of small arms with magnetic sensor, the malfunction of small arms might be caused by strong external magnetic fields. In this study, the effects of magnetic sensor on external magnetic fields were analyzed, and optimal magnetic shield and shield structure were designed through M&S. In addition, the magnetic-shielding effectiveness of magnetic sensor in small arms was verified with commercial shielding materials. As a result, it was demonstrated that the Fe-Cu-Si-Nd-B with the structure of multi-layer metallic shields was shown the magnetic-shielding effectiveness of 83 % for an external permanent magnet and 19 % for an alternating magnetic field of 180 dBpT at 60 Hz, respectively.

Finite Element Analysis of the Transient Characteristics of a Superconducting A.C. Generator (유한요소법에 의한 초전도교류 발전기의 과도 특성 해석)

  • 한성진;배동진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.1
    • /
    • pp.24-30
    • /
    • 1991
  • This paper deals with the analysis of the transient characteristics of a superconducting a.c. generator(SCG) using Finite Element Method. Since the magnetic field induced by the field current and the armature currents are not sinusoidally distributed in a generator, the conventional equivalent circuit method, in general, uses the fundamental component only and is done in frequency domain. But the finite element analysis makes it possible to analyze the transient magnetic field distribution and the electrical characteristics of the double shields of SCG in time domain.

  • PDF

A New Concept of Magnetic Cable for Safe Mobile Power Delivery (안전한 전력전달을 위한 새로운 형태의 자기케이블)

  • Lee, Woo-Young;Huh, Jin;Choi, Su-Yong;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.542-553
    • /
    • 2011
  • A magnetic cable that can safely deliver high frequency AC electric power in flammable or sensitive workplaces by preventing from arcs and electric shocks is firstly proposed in this paper. Several new magnetic cable structures with magnetic shields, which are composed of such cancel coil, cancel copper plate, and cancel copper pipe, were compactly implemented by considering and analyzing fringe field and thus the parallel leakage flux is drastically reduced. The output power and efficiency of a prototype magnetic cable with 1.5 m length and 5 cm gap were measured as 353.8W and 68%, where the source current and switching frequency were 10 $A_{rms}$ and 20 kHz, respectively. The proposed magnetic cables are fully analyzed and verified by finite-element method (FEM) simulations and experiments. The results are in a good agreement.

The Characteristic Analysis of the Ag/Bi-2223 Tape and the Flux damper in GTS Synchronous Motor through 3-Dimensional Magnetic Field Analysis Using F.E.M (3차원 자계분포해석을 이용한 고온초전도동기모터에서의 Ag/Bi-2223 Tape 및 Flux Damper의 특성해석)

  • 송명곤;윤용수;이상진;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.170-172
    • /
    • 2000
  • This paper deals with the characteristic analysis of the flux damper with respect to the load, and the stability of Ag/Bi-2223 tapes in a high-Tc superconducting (HTS) synchronous motor. To find out the magnetic field distribution in a detailed model of the actual motor, the experimentally measured currents of the armature and the field windings are used as input parameters. The simulation results show that the flux damper shields the time varying field up to 10%, reduces armature reactance during the motor operation and during load changes, improving the stable motor operation. And it was observed that the flux damper generates loss by means of leakage flux, but this is not significant and it doesn't degrade the performance of the TS synchronous motor.

  • PDF

Magnetic Shielding Characteristics of the Slitted Electrothermal Shield (틈새를 낸 열전자 차폐막의 자기차폐특성)

  • 이홍배;배동진;김석환;원영진;한성진;차귀수;한송엽
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.562-566
    • /
    • 1991
  • Many research and development activities have found that Superconducting Generators (SCG) have advantages such as high efficiency, light weight, small size, large unit size and good steady-state stability over conventional ones. However the transient stability of SCG is comparable to that of conventional ones. One way to improve the transient stability of SCG is to apply quick-response excitation system to the SCG. For this purpose, an SCG with an electrothermal shield of short electric time constants should be developed. In this paper, a new electrothermal shield, called slitted electrothermal shield(SES), is proposed. The SES can easily transmit radiated heat into the ends of the shield as in the conventional electrothermal shields(CES) and can easily pass magnetic flux produced by armature and field windings. By finite element analysis and experimental test, the slitting effects of SES on magnetic shielding are compared. Good agreement is obtained between simulated and test results.

  • PDF

Magnetic Shielding Effect of Amorphous Strips in Low Frequency Field (비정질 연자성재료를 이용한 복층 차폐체의 저주파 자기장 차폐효과)

  • Kim, S.G.;Hur, J.;Park, P.G.;Chung, Y.C.;Kim, Y.B.;Kim, T.K.
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.6
    • /
    • pp.341-345
    • /
    • 1998
  • Magnetic shielding effect of cylinderical ahields made of commericial amorphous ribbons has been studied. The shell-arrangement-order of double shell shield has been found to show a striking differencein shielding factor. In low applied field region, a 2605CO-2705M-shield (outer shell: 2605CO, inner shell: 2705M) yields two times higher shielding factor than a 2705M-2605CO-shield (outer shell: 2705M, inner shell: 2605CO). The reasons are as follows: In case of 2605CO-2705M-shield, the outer shell is not easily saturated and effectively shields the applied field. In addition, the inner shell shows high shielding factor in the field shielded by the outer shell. In case of 2705M-2605CO-shield, the outer shell is saturated at very low-field as well as the inner shell shows low shielding factor in the field shielded by the outer shell.

  • PDF

Reduction Effects of Electromagnetic fields in Conductor Shields (도체차폐판의 전자계 감소효과)

  • Kang, Dae-Ha;Kim, Won-Hee;Lee, Yuong-Sik;Son, Jung-Dae;Park, Yoon-Dong;Park, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1595_1596
    • /
    • 2009
  • In this study reduction effects of magnetic field were analyzed using multi-conductor method in analysis of shield. The method can be effective in the analysis because of reducing the amount of allocated memory and computing time. And also the method can be applicable to analysis of the induced current distributions and skin effect in shield. The results of the analysis are presented.

  • PDF