• Title/Summary/Keyword: magnetic resonance cholangiopancreatography

Search Result 20, Processing Time 0.023 seconds

Characteristics of Pediatric Pancreatitis on Magnetic Resonance Cholangiopancreatography

  • Hwang, Jae-Yeon;Yoon, Hye-Kyung;Kim, Kyung Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.18 no.2
    • /
    • pp.73-84
    • /
    • 2015
  • Pediatric pancreatitis is not uncommon and results in considerable morbidity and mortality in the affected children. Unlike adults, pediatric pancreatitis is more frequently associated with underlying structural abnormalities, trauma, and drugs rather than an idiopathic etiology. Magnetic resonance cholangiopancreatography (MRCP) is a good imaging modality for evaluating pancreatitis and determining etiology without exposure to radiation. This article focuses on MRCP findings associated with various causes of pancreatitis in children, particularly structural abnormalities of the pancreaticobiliary system, as well as describing the feasibility, limitations, and solutions associated with pediatric MRCP.

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.

Spontaneous Perforation of Common Bile Duct: Abscess Formation Presenting as a Choledochal Cyst

  • Kim, Cho Hee;Kim, Dae Jung;Kim, Kyoung Ah;Choi, Sung Hoon;Kwon, Chang-Il
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.254-258
    • /
    • 2016
  • Spontaneous perforation of the bile duct without any traumatic or iatrogenic injury is extremely rare. We report a case of abscess formation related to spontaneous perforation of the common bile duct by a gallstone, mimicked a cholecochal cyst.

Non-invasive MR Demonstration of the Fistula between Pancreatic Pseudocyst and Portal Vein: A Case Report (자기공명영상을 이용하여 비침습적으로 진단된 췌장 가성낭종과 간문맥 사이의 누공: 증례 보고)

  • Kim, Sung Min;Lee, Young Hwan;Kang, Ung Rae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.171-175
    • /
    • 2014
  • Pancreatic pseudocyst rupture into the portal vein is a very rare complication and only three reported cases were confirmed using MRI. We report the case of a 50-year-old man with fistula formation between the pseudocyst and the portal vein, confirmed noninvasively by MRI. T2-weighted MR images and magnetic resonance cholangiopancreatography showed fluid signal intensity within the portal, superior mesenteric, and splenic veins, and a direct communication between the pseudocyst and the portal vein.

Pancreaticothoracic Fistula Presenting with Hemoptysis and Pneumothorax in a Chronic Alcoholic Patient

  • Lee, Si Nae;Lee, Kyung Hee;Chung, Seok;Nam, Hae Sung;Cho, Jae Hwa;Ryu, Jeong Seon;Kwak, Seung Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.76 no.5
    • /
    • pp.240-244
    • /
    • 2014
  • Pancreaticothoracic fistula is a rare complication of acute or chronic alcoholic pancreatitis. It may present with various symptoms, like dyspnea, abdominal pain, cough, chest pain, fever, back pain, hemoptysis, fatigue, or orthopnea. Pancreaticothoracic fistula can be detected by magnetic resonance cholangiopancreatography (MRCP), endoscopic retrograde cholangiopancreatography (ERCP), or computed tomography. MRCP has high sensitivity and fewer side effects, and thus it has recently been recommended as the first choice for the detection of pancreaticothoracic fistula. On the other hand, ERCP enables the detection and treatment of pancreaticothoracic fistula and allows for stent insertion; for this reason it is a commonly used modality in pancreaticothoracic fistula cases. Herein, the authors describe a case of pancreaticothoracic fistula detected by ERCP and MRCP that manifested only respiratory symptoms, namely hemoptysis and pneumothorax without abdominal pain, which commonly accompanies pancreatitis.

Biliary ascariasis misidentified as a biliary stent in a patient undergoing liver resection

  • Hochang Chae;Suk Won Suh;Yoo Shin Choi;Hee Ju Sohn;Seung Eun Lee;Jae Hyuk Do;Hyun Jeong Park
    • Parasites, Hosts and Diseases
    • /
    • v.61 no.2
    • /
    • pp.194-197
    • /
    • 2023
  • Ascaris lumbricoides causes one of the most common soil-transmitted helminthiases globally. The worms mostly infect the human small intestine and elicit negligible or nonspecific symptoms, but there are reports of extraintestinal ectopic ascariasis. We describe a rare case of biliary ascariasis mistaken for biliary stent in a 72-year-old female patient with a history of liver resection. She visited our outpatient clinic complaining of right upper quadrant pain and fever for the past week. She had previously undergone left lateral sectionectomy for recurrent biliary and intrahepatic duct stones 2 years ago. Besides mildly elevated gamma-glutamyl transferase levels, her liver function tests were normal. Magnetic resonance cholangiopancreatography revealed a linear filling defect closely resembling an internal stent from the common bile duct to the right intrahepatic bile duct. A live female A. lumbricoides adult worm was removed by endoscopic retrograde cholangiopancreatography (ERCP). Despite a significant decrease of the ascariasis prevalence in Korea, cases of biliary ascariasis are still occasionally reported. In this study, a additional case of biliary ascariasis, which was radiologically misdiagnosed as the biliary stent, was described in a hepatic resection patient by the worm recovery with ERCP in Korea.

Usefulness of Superparamagnetic Iron Oxide (SPIO) as a Negative Oral Contrast Agent in MR Cholangiopancreatography (자기공명 담관췌장초영술에서 음성 경구 조영제로 사용한 초상자성 산화철 제재의 유용성)

  • 이정민;송원규;이종덕
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.49-56
    • /
    • 2001
  • Purpose : To evaluate value of superparamagnetic iron oxide (SPIO) as a negative oral contrast agent in MR cholangiopancreatography (MRCP). Materials and methods : Forty-eight patients with suspected biliary tract or pancreatic diseases and six healthy volunteers were enrolled in this study. All MR images were obtained using a 1.5 T MR unit. MR-CP using fat-suppressed half-Fourier acquisition single-shot turbo spin echo (HASTE) and turbo spin echo (TSE) techniques were performed and reconstructed with maximal intensity projection (MIP). To determine the most optimal concentration of SPIO to obliterate the high signal intensity of water, a phantom experiment was conducted with various concentrations of SPIO-water mixture. Two radiologists evaluated pre- and postcontrast MRCPS. The contrast enhancement was assessed on the basis of loss of signal intensity in the stomach and duodenum. Results : In the phantom experiment, a significant increase of percentage of signal intensity loss (PSIL) occurred in concentration of 22.4 ugFe/ml (Feridex1 ml diluted with water 500 ml). Postcontrast MRCP showed an improved image quality compared with precontrast images. The rate of improvement in the diagnosis of diseases of the common bile duct and pancreatic duct was 25% (12/48). Conclusion : In patients with suspected biliary tract and pancreatic diseases, the SPIO is useful as a negative oral contrast agent for MRCP and provides an improvement of image quality.

  • PDF

The Qualitative Analysis of Single Shot Fast Spin Echo (SSFSE) and Maximum Intensity Projection (MIP) on Magnetic Resonance Cholangiopancreatography

  • Park, Cheol-Soo;Cho, Jae-Hwan;Lee, Hae-Kag;Dong, Kyung-Rae;Chung, Woon-Kwan;Seok, Jong-Min;Han, Man-Seok;Lee, Sun-Yeob;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.138-144
    • /
    • 2012
  • 3-dimensional magnetic resonance cholangiopancreatography (MRCP) images reconstructed using the maximum intensity projection technique were analyzed qualitatively in patients diagnosed with pancreatobiliary diseases to determine their diagnostic utility. Single shot fast spin echo (SSFSE), fast spin echo (FSE) and 3-dimensional reconstructive images were acquired from 20 patients diagnosed histologically with pancreatobiliary diseases using a 3.0T MR scanner. According to qualitative analysis, the fast spin echo images and 3-dimensional reconstructed images of the hepatic duct, gall bladder and common bile duct had a higher signal to noise ratio (SNR) than the single shot fast spin echo images. Fast spin echo images and 3-dimensional reconstructed images did not show any differences. The contrast to noise ratio of the hepatic duct, gallbladder and common bile duct on the fast spin echo images and 3-dimensional reconstructed images was higher than that of the single shot fast spin echo images. The fast spin echo images and 3-dimensional reconstructed images showed similar quality.

Comparison of Diagnostic Accuracy of Three-Dimensional MR Cholangiopanceatography and ERCP in Various Extrahepatic Biliary Lesions (여러 간외담도 질환에서 삼차원적 자기공명 췌담관 조영술과 내시경적 역행성 췌담관 조영술과의 비교: 진단적 정확성을 중심으로)

  • 김경숙;이문규;김명환;이승규;김표년;오용호
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.148-153
    • /
    • 1997
  • Purpose: To evaluate the diagnostic role of a three-dimensional MR cholangiopancreatography (MRCP) over endoscopic retrograde cholangio-pancreatography (ERCP) in various extrah-epatic biliary disease. Materials and Methods: MRCP and ERCP were performed in 45 consecutive patients with suspected extrahepatic biliary diseases. MRCP was obtained using a reverse fast imaging with a steady-state free precession (reverse FISP: PSIF) sequence, and then images were reconstructed by standard MIP algorithm. The predictability of biliary dilatation and level of obstruction of MRCP was evaluated using ERCP as a gold standard. The accuracy distinguishing malignant from benign lesions, and overall diagnostic accuracy were compared between MRCP and ERCP. Results: The sensitivity, specificity and accuracy of MRCP in predicting biliary dilatation were 94.6%, 75.0% and 91.1%, respectively. The level of obstruction was accurate in 87.0% with MRCP. The sensitivity, specificity and accuracy of MRCP and ERCP in distinguishing malignant from benign lesions were 76.2%, 87.5% and 82.2% and 71.4%, 83.3% and 77.8%, respectively. The overall diagnostic accuracy was 60.0% with MRCP and 55.6% with ERCP. Conclusion: 3D MRCP shows a good diagnostic value compared to that of ERCP, and can replace a ERCP.

  • PDF