• Title/Summary/Keyword: maximum heart distance

Search Result 17, Processing Time 0.031 seconds

The Usefulness of Magnification of the Heart Shadow in Chest Radiography (흉부 촬영시 심음영 확대에 따른 유용성에 관한 연구)

  • Park, Eun-Gyung;Lee, Kun-Young;Jung, Young-Tae;Dong, Kyung-Rae;Ji, Youn-Sang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.119-125
    • /
    • 2010
  • In order to demonstrate the value of long-distance radiography, we have studied how distance affects images in chest frontal radiography and compared short-distance and long-distance images in chest lateral radiography. Cardiothoracic ratio(CTR %) of 50 patients with no disease in the chest(10 each at the age of 20~60) were evaluated in Supine AP(100 cm), Sitting AP(100 cm), Sitting AP(180 cm), and Erect PA(180 cm). In lateral radiography, we evaluated and compared left lateral radiography(100 cm and 180 cm) of the patients based on the horizontal maximum of the heart. The average value of CTR(%) were 0.48 in Erect PA(180 cm), 0.52 in Supine AP(100 cm), 0.50 in Sitting AP(100 cm), 0.49 in Sitting AP(180 cm), which were Supine AP(100 cm) > Sitting AP(100 cm) > Sitting AP(180 cm) > Erect PA(180 cm). The average value of Maximum transverse diameter of left of the cardiac(MLD), which showed how much axis of spine was slanted to the left, was 90.67 mm in Erect PA(180 cm), 103.92 mm in Supine AP(100 cm), 93.54 mm in Sitting(100 cm), 89.84 mm in Sitting AP(180 cm), 58.11 mm in the minimum value and 118.79 mm in the maximum value. The average value of Maximum transverse diameter of right side of the cardiac(MRD), which suggested how much axis of spine was slanted to the right, was 47.18 mm in Erect PA(180 cm), 48.12 mm in Supine AP(100 cm), 44.98 mm in Sitting AP(180 cm), and the minimum value 26.84 mm and the maximum value 65.30 mm. There was no standard method to calculate; therefore, the horizontal maximum of the heart was used for lateral radiography. The average value was 121.07 mm in 100 cm and 109.76 mm in 180 cm. Sitting AP(180 cm) among the types was closest to C-PA(180 cm). As a result, during C-AP radiography, long-distance radiography lessened shadow of the heart more than that of short distance, Sitting position more than Supine position.

  • PDF

Effect of Forest Road Types on Salivary Cortisol, Blood Lactate and Heart Rate during Walking Exercise

  • JaeHeon Son;Junwon Min;KiHong Kim
    • International journal of advanced smart convergence
    • /
    • v.12 no.4
    • /
    • pp.386-394
    • /
    • 2023
  • This study investigated changes in salivary cortisol, lactic acid, and heart rate along the route during walking exercise in a forest environment for the purpose of reducing stress. Walking exercise in a forest environment was conducted on a Hill Type (Distance: 800m, Average slope 25°, Altitude 112m) and Step Type (Distance: 800m, Average slope 25°, Altitude 114m) routes for 10 female college students in their 20s. The subjects were asked to walk at a speed of 60 bpm. The resulting changes in salivary cortisol, lactate, and average heart rate during exercise were compared and analyzed using Repeated Measurement two-way ANOVA, and the maximum heart rate during exercise and average heart rate at rest were compared and analyzed using paired t-test, and the following results were obtained. First, there was no significant difference in salivary cortisol depending on the type and period of the forest, but it tended to gradually decrease. Second, there was a significant difference in lactic acid depending on the type and period, and it was higher in Step Type. Third, there was a significant difference in the average heart rate during exercise, and it was higher in Step Type. Fourth, there was a significant difference in maximum heart rate during exercise, and it was higher in Step Type. Fifth, there was no significant difference in average heart rate during rest. In summary, walking exercise in a forest environment can be effective for stress reduction for female college students in their 20s, but it appears that forest routes should be selected according to physical strength level, and walking exercise in a forest environment for long periods of time is not recommended. For this purpose, it is suggested that it is appropriate to select the Hill Type route.

Morphological Factors and Cardiac Doses in Whole Breast Radiation for Left-sided Breast Cancer

  • Guan, Hui;Dong, Yuan-Li;Ding, Li-Jie;Zhang, Zi-Cheng;Huang, Wei;Liu, Cheng-Xin;Fu, Cheng-Rui;Zhu, Jian;Li, Hong-Sheng;Li, Miao-Miao;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.7
    • /
    • pp.2889-2894
    • /
    • 2015
  • Background: To investigate the impact of the breast size, shape, maximum heart depth (MDH), and chest wall hypotenuse (the distance connecting middle point of the sternum and the length of lung draw on the selected transverse CT slice) on the volumetric dose to heart with whole breast irradiation (WBI) of left-sided breast cancer patients. Materials and Methods: Fifty-three patients with left-sided breast cancer undergoing adjuvant intensity-modulated radiotherapy (IMRT) were enrolled in the study. The primary breast size and shape, MHD and DCWH (chest wall hypotenuse) were contoured on radiotherapy (RT) planning CT slices. The dose data of hearts were obtained from the dose-volume histograms (DVHs). Data were analyzed by one-way analysis of variance (ANOVA), Student's t-test and linear regression analysis. Results: Breast size was independent of heart dose, whereas breast shape, MHD and DCWH were correlated with heart dose. The shapes of breasts were divided into four types, as the flap type, hemisphere type, cone type and pendulous type with heart mean dose being $491.8{\pm}234.6cGy$, $752.7{\pm}219.0cGy$, $620.2{\pm}275.7cGy$, and $666.1{\pm}238.0cGy$, respectively. The flap type of breasts shows a strong statistically reduction in heart dose, compared to others (p=0.008 for V30 of heart). DCWH and MHD were found to be the most important parameters correlating with heart dose in WBI. Conclusions: More attention should be paid to the heart dose of non-flap type patients. The MHD was found to be the most important parameter to correlate with heart dose in tangential WBI, closely followed by the DCWH, which could help radiation oncologists and physicsts evaluate heart dose and design RT plan in advance.

Assessment of the proximity between the mandibular third molar and inferior alveolar canal using preoperative 3D-CT to prevent inferior alveolar nerve damage

  • Lee, Byeongmin;Park, Youngju;Ahn, Janghoon;Chun, Jihyun;Park, Suhyun;Kim, Minjin;Jo, Youngserk;Ahn, Somi;Kim, Beulha;Choi, Sungbae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.30.1-30.7
    • /
    • 2015
  • Background: The inferior alveolar nerve (IAN) may be injured during extraction of the mandibular third molar, causing severe postoperative complications. Many methods have been described for evaluating the relative position between the mandibular third molar and the inferior alveolar canal (IAC) on panoramic radiography and computed tomography, but conventional radiography provides limited information on the proximity of these two structures. The present study assessed the benefits of three-dimensional computed tomography (3D-CT) prior to surgical extraction of the mandibular third molar, to prevent IAN damage. Methods: This retrospective study included 4917 extractions in 3555 patients who presented for extraction of the mandibular third molars. The cases were classified into three groups, according to anatomical relationship between the mandibular third molars and the IAC on panoramic radiography and whether 3D-CT was performed. Symptoms of IAN damage were assessed using the touch-recognition test. Data were compared using the chi-square test and Fisher's exact test. Results: Among the 32 cases of IAN damage, 6 cases were included in group I (0.35 %, n = 1735 cases), 23 cases in group II (1.1 %, n = 2063 cases), and 3 cases in group III (0.27 %, n = 1119 cases). The chi-square test showed a significant difference in the incidence of IAN damage between groups I and II. No significant difference was observed between groups I and III using Fisher's exact test. In the 6 cases of IAN damage in group I, the mandibular third molar roots were located lingual relative to the IAC in 3 cases and middle relative to the IAC in 3 cases. The overlap was ${\geq}2mm$ in 3 of 6 cases and 0-2 mm in the remaining 3 cases. The mean distance between the mandibular third molar and IAC was 2.2 mm, the maximum distance 12 mm, and the minimum distance 0.5 mm. Greater than 80 % recovery was observed in 15 of 32 (46.8 %) cases of IAN damage. Conclusions: 3D-CT may be a useful tool for assessing the three-dimensional anatomical relationship and proximity between the mandibular third molar and IAC in order to prevent IAN damage during extraction of mandibular third molars.

Effect of the Fall Prevention Program(EPP) on gait, balance and muscle strength in elderly women at a nursing home (낙상예방 프로그램이 양로원 여성노인의 보행, 균형 및 근력에 미치는 영향)

  • Jeon, Mi-Yang;Choe, Myoung-Ae
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.1
    • /
    • pp.5-23
    • /
    • 2002
  • Purpose: To determine the effect of the Fall Prevention Program(EPP) on gait, balance and muscle strength in elderly women at a nursing home. Method: The subjects of this consisted of 38 elderly women between the ages of 70 to 89 years living at a nursing home located in Seoul. Each of the experimental group and control group was composed of 19 subjects. The subjects in experimental group have participated in FPP for the 8 weeks which consisted of exercise, education and foot care. They started to exercise for 40 minutes per session, 3 sessions a week during the 1st week at 40% of age adjusted maximum heart rate. From the 2nd week to the 4th week, they increased the duration of exercise to 50 minutes per session and the intensity to 60% of age-adjusted maximum heart rate. They participated in 50 minutes at 60% of age-adjusted maximum heart rate from the 5th week to the 8th week. Each exercise session consisted of 10 minutes of warming-up exercise, 30 minutes of conditioning exercise and 10 minutes of cooling-down exercise. They participated in education for 20 minutes per week from the 1st week to the 4th week. Then they participated in a 30-minute foot care program per week from the 5th week to the 8th week. Gait, balance and muscle strength for each subject were measured before and after FPP. Gait was evaluated by step length, step width, gait speed and walking distance. Balance was measured by the duration of standing on one leg with their eyes closed and open each, and a get-up and go test. Grip strength was measured by hand dynamometer. Hip extensor and flexor strength, knee extensor and flexor strength and ankle plantarflexor and dorsiflexor strength were measured by manual muscle tester. Data was analyzed using SPSS form Windows. t-test and Chi square test were utilized as a homogeneity test. Repeated measure ANOVA was used to test the effect of FPP. Result: 1) Step width significantly decreased, and step length, gait speed and walking distance significantly increased in the experimental group compared with the control group after FPP(p<0.005). 2) There was no significant change in standing time on one leg with their eyes closed after FPP. The standing time on leg with their eyes open and the time of "get-up and go" significantly decreased in the experimental group compared with the control group after FPP(p<0.005). 3) Muscle strength-grip strength, hip extensor and flexor strength-significantly increased in the experimental group compared with the control group after FPP(p<0.005). 4) There was no significant difference of frequency of fall between the experimental group and control group during the period of FPP. Conclusion: These results suggest that FPP can increase gait, balance and muscle strength of elderly women at a nursing home.

  • PDF

Literature Review on One.Handed Manual Material Handling (한손 수동물자취급에 관한 문헌 조사)

  • Mo, Seung-Min;Kwag, Jong-Seon;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.5
    • /
    • pp.819-829
    • /
    • 2010
  • By referring thirty-seven previous studies on manual material handling (MMH), this paper analyzed guidelines and main factors of one-handed tasks. The previous studies concerned main factors of distance, weight, frequency, posture, gender, age, training, direction of force, height of the force exerted, and object shape and size. Based on these factors, the criteria used to understand one-handed tasks were objective measures of maximum strength, reaction force, etc., psychophysical measures of maximum acceptable frequency and weight, etc., and physiological measures of oxygen uptake, heart rate, electromyography, etc. An allowance threshold model regarding quantitative and objective fatigue and workload would be suggested for future research. This study would be expected that it serve to establish and Korean recommendations of one-handed tasks.

A Study for the Development of Sit/Stand Kitchen Furniture to Reduce Fatigue in Housekeeping Activities (가사활동에 따른 피로도 감소를 위한 입좌식(立座式) 부엌가구의 개발에 관한 연구)

  • Kim, Chol-Hong
    • IE interfaces
    • /
    • v.15 no.1
    • /
    • pp.82-88
    • /
    • 2002
  • A study was conducted to develop user-centered kitchen furniture and workspace to reduce fatigue and to prevent housewives's disorders such as low back pain and musculoskeletal disorders from housekeeping activities. A questionnaire survey and interview were performed on 150 households those live in 32Pyung-type($105m^2$) apartment in Seoul vicinity. Also actual housekeeping activities for 24 hours were video-taped for further motion analysis. Results of the study revealed that housewives complained the inconvenience and small size of storage space, and worksurface height as the most important problems to be considered for redesign. And they responded, if feasible, sitting is preferred over standing while they are working. After adapting a sit/stand chair in the kitchen, a physiological experiment measuring heart rate(HR) and oxygen consumption($VO_2$) as response variables was conducted to examine the effects of sit/stand chair in reducing physiological demand during housekeeping activities. The results showed that working on sit/stand chair reduced energy expenditures by maximum of 30% and 31.0% in terms of HR and $VO_2$, respectively. Also rearrangement of kitchen structure based on motion analysis showed that walking distance during daily housekeeping activities can be reduced by 5.5% on the average. Hence, it is concluded that adapting a sit/stand chair in the kitchen could reduce fatigue and occupational disorders of housewives from extended housekeeping activities.

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

Analysis of the Parameters of Magnetocardiography Depending on the Age and Gender (남녀 및 나이에 따른 심자도 변수 차이 분석)

  • Lim, Hyun-Kyoon;Chung, Nam-Sik;Lee, Yong-Ho;Kwon, Hyuk-Chan;Joung, Bo-Young;Park, Yong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.530-538
    • /
    • 2007
  • Magnetocardiography (MCG) is a device to measure the magnetic field from the heart. It is a noninvasive device and takes only few minutes to record magnetocardiogram from a subject. In this study, we compared the difference of MCG data recorded from 56 normal subjects in early twenties (28 males and 28 females, mean $age=21.0{\pm}1.6$ years) and 36 elderly subjects (20 males and 16 females, mean $age=61.9{\pm}6.9$ years) for the analysis of the age and gender difference. A total of 24 parameters used in the analysis were derived from QRS complex, R-wave, T-wave, and ST-T period. As a result, seven parameters including maximum current angle and map angle showed the significant difference (p<0.01 and p<0.05, respectively) between young males and young females. Significant difference (p<0.05) between elderly males and elderly females was found from a parameter, pole distance at T-wave peak. In the comparison of age difference, seven parameters regarding current moment, pole distance, and dynamics showed the significant difference between young and elderly males. Eight parameters also showed significant difference (p<0.05) between two younger and elderly female groups. Results showed that parameters regarding current moment, pole distance, and dynamics might be changed when people get older. In conclusion, gender and age difference should be considered when MCG data are analyzed for certain parameters.

Evaluation of Dose Reduction of Cardiac Exposure Using Deep-inspiration Breath Hold Technique in Left-sided Breast Radiotherapy (좌측 유방암 방사선 치료에서 깊은 들숨 호흡법을 이용한 심장 선량 감소 평가)

  • Jung, Joo-Young;Kim, Min-Joo;Jung, Jae-Hong;Lee, Seu-Ran;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.278-283
    • /
    • 2013
  • Breast cancer is the leading cause of cancer death in women worldwide and the number of women breast cancer patient was increased continuously. Most of breast cancer patient has suffered from unnecessary radiation exposure to heart, lung. Low radiation dose to the heart could lead to the worsening of preexisting cardiovascular lesions caused by radiation induced pneumonitis. Also, several statistical reports demonstrated that left-sided breast cancer patient showed higher mortality than right-sided breast cancer patient because of heart disease. In radiation therapy, Deep Inspiration Breath Hold (DIBH) technique which the patient takes a deep inspiration and holds during treatment and could move the heart away from the chest wall and lung, has showed to lead to reduction in cardiac volume and to minimize the unnecessary radiation exposure to heart during treatment. In this study, we investigated the displacement of heart using DIBH CT data compared to free-breathing (FB) CT data and radiation exposure to heart. Treatment planning was performed on the computed tomography (CT) datasets of 10 patients who had received lumpectomy treatments. Heart, lung and both breasts were outlined. The prescribed dose was 50 Gy divided into 28 fractions. The dose distributions in all the plans were required to fulfill the International Commission on Radiation Units and Measurement specifications that include 100% coverage of the CTV with ${\geq}95%$ of the prescribed dose and that the volume inside the CTV receiving >107% of the prescribed dose should be minimized. Scar boost irradiation was not performed in this study. Displacement of heart was measured by calculating the distance between center of heart and left breast. For the evaluation of radiation dose to heart, minimum, maximum and mean dose to heart were calculated. The present study demonstrates that cardiac dose during left-sided breast radiotherapy can be reduced by applying DIBH breathing control technique.