• Title/Summary/Keyword: median-effect principle

Search Result 6, Processing Time 0.025 seconds

Intervention Effects of Nedaplatin and Cisplatin on Proliferation and Apoptosis of Human Tumour Cells in Vitro

  • Su, Xiang-Yu;Yin, Hai-Tao;Li, Su-Yi;Huang, Xin-En;Tan, Hua-Yang;Dai, Hong-Yu;Shi, Fang-Fang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4531-4536
    • /
    • 2012
  • Objective: To study synergistic effects of nedaplatin and cisplatin on three human carcinoma cell lines (esophageal carcinoma cell line Eca-109, ovarian carcinoma Skov-3 and cervical carcinoma Hela). Methods: Inhibition effects were evaluated by MTT assay and cell apoptosis was detected by flow cytometry. In addition, changes of Ki-67, Bax and Bcl-2 at mRNA and protein levels were quantified by RT-PCR and Western blotting. Results: Growth inhibition in each cell lines was dose-dependent after exposure to nedaplatin or cisplatin alone. The interaction of the two drugs was synergistic at higher concentrations according to the median-effect principle. The inhibition rates with nedaplatin, cisplatin and combined treatment were $41.9{\pm}4.1%$, $47.4{\pm}2.9%$, $52.5{\pm}0.9%$(Eca-109), $39.0{\pm}1.26%$, $45.0{\pm}1.45%$, $56.2{\pm}1.44%$ (Skov-3) and $44.8{\pm}2.11%$, $46.9{\pm}0.99%$, $56.6{\pm}1.83%$ (Hela) respectively, with increase in apoptosis. Compared with the nedaplatin or cisplatin alone treatment group, the combinative treatment group's Ki-67 and bcl-2 mRNA (protein) expression was decreased while that of Bax mRNA (protein) was increased. Conclusion: Compared to the effects of nedaplatin or cisplatin alone at high concentrations, combination of nedaplatin and cisplatin at low concentrations proved to be much more effective for inhibition of proliferation and the induction of apoptosis in the Eca-109, Skov-3 and Hela cell lines.

Time Series Data Cleaning Method Based on Optimized ELM Prediction Constraints

  • Guohui Ding;Yueyi Zhu;Chenyang Li;Jinwei Wang;Ru Wei;Zhaoyu Liu
    • Journal of Information Processing Systems
    • /
    • v.19 no.2
    • /
    • pp.149-163
    • /
    • 2023
  • Affected by external factors, errors in time series data collected by sensors are common. Using the traditional method of constraining the speed change rate to clean the errors can get good performance. However, they are only limited to the data of stable changing speed because of fixed constraint rules. Actually, data with uneven changing speed is common in practice. To solve this problem, an online cleaning algorithm for time series data based on dynamic speed change rate constraints is proposed in this paper. Since time series data usually changes periodically, we use the extreme learning machine to learn the law of speed changes from past data and predict the speed ranges that change over time to detect the data. In order to realize online data repair, a dual-window mechanism is proposed to transform the global optimal into the local optimal, and the traditional minimum change principle and median theorem are applied in the selection of the repair strategy. Aiming at the problem that the repair method based on the minimum change principle cannot correct consecutive abnormal points, through quantitative analysis, it is believed that the repair strategy should be the boundary of the repair candidate set. The experimental results obtained on the dataset show that the method proposed in this paper can get a better repair effect.

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

Evaluation of Neoadjuvant Chemotherapy Effect in Osteosarcoma (골육종에서 술전 항암화학요법의 효과 판정)

  • Joo, Min Wook;Kang, Yong-Koo;Yoo, Ie Ryung;Choi, Woo Hee;Chung, Yang-Guk;Kim, Dong-Hyun;Kang, Jin-Woo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.2
    • /
    • pp.66-73
    • /
    • 2014
  • Purpose: Various diagnostic imaging modalities have been used to evaluate the effect of neoadjuvant chemotherapy for osteosarcoma early and noninvasively. We evaluated the effectiveness of imaging studies of plain radiographs and positron-emission tomography/computed tomography (PET/CT) in predicting neoadjuvant chemotherapy effect for osteosarcoma and tried to establish a general principle in interpretation of PET/CT parameters. Materials and Methods: Eighteen patients who underwent two cycles of neoadjuvant chemotherapy and surgical excision for osteosarcoma were enrolled. There were 13 males and 5 females, with a median age of 19 (11-63) years. Fifteen patients of 18 had the American Joint Committe on Cancer (AJCC) stage IIB. They had plain radiographs and PET/CT before and after neoadjuvant chemotherapy. The resected tumor specimens were pathologically examined to determine histological response grade using a conventional mapping method. Statistical analysis was performed to evaluate the correlation between histopathological necrosis rate, and radiographic finding category, post-chemotherapy maximum standardized uptake value (SUVmax), average standardized uptake value and metabolic tumor volume (MTV) as well as reduction rates of them. Results: Eight patients were good responders to neoadjuvant chemotherapy based on histological evaluation. Median SUVmax reduction rate was 73 (23-77) % in good responders and 42 (-32-76) % in poor responders. Median MTV reduction rate was 93.5 (62-99) % in good responders and 46 (-81-100) % in poor responders. While radiographic finding category was not different according to histological response (p=1.0), SUVmax reduction rate was significantly different (p=0.041). Difference in MTV reduction rates approached statistical significance as well (p=0.071). Conclusion: While radiographic finding category was not reliable to assess neoadjuvant chemotherapy effect for osteosarcoma, reduction rate of SUVmax was a useful indicator in this study. As parameters of PET/CT can be influenced by various factors of settings, different centers have to make an effort to establish their own standard of judgement with reference of previous studies.

Inhaled Formaldehyde Induces Bone Marrow Toxicity via Oxidative Stress in Exposed Mice

  • Yu, Guang-Yan;Song, Xiang-Fu;Liu, Ying;Sun, Zhi-Wei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5253-5257
    • /
    • 2014
  • Formaldehyde (FA) is an economically important chemical, and has been found to cause various types of toxic damage to the body. Formaldehyde-induced toxic damage involves reactive oxygen species (ROS) that trigger subsequent toxic effects and inflammatory responses, which may increase risk of cancer. Therefore, in the present study, we aimed to investigate the possible toxic mechanism in bone marrow caused by formaldehyde. In accordance with the principle of randomization, the mice were divided into four groups of 6 mice per group. One group was exposed to ambient air and the other three groups were exposed to different concentrations of formaldehyde (20, 40, $80mg/m^3$) for 15 days in the respective inhalation chambers, 2h a day. At the end of the 15-day experimental period, all mice were killed. Bone marrow cells were obtained. Some of those were used for the determination of blood cell numbers, bone marrow karyote numbers, CFU-F, superoxide dismutase (SOD) activity and malondialdehyde (MDA) content; others were used for the determination of mitochondrial membrane potential (MMP), cell cycle and Bcl-2, Bax, CytC protein expression. WBC and PLT numbers in median and high dose groups were obvious reduced, but there was no change on RBC numbers. There was also reduced numbers of bone marrow karyotes and CFU-F in the high dose group. SOD activity was decreased, but MDA content was increased. MMP and Bcl-2 expression were decreased with increasing formaldehyde concentration, while expression of Bax and Cyt C was increased. We also observed change in cell cycling, and found that there was S phase arrest in the high dose group. Our study suggested that a certain concentration of formaldehyde could have toxic effects on the hematopoietic system, with oxidative stress as a critical effect.

A Experimental Study on Exclusion Ability of Riprap into Bypass Pipe (저층수 배사관 내 유입된 사석 배출능력에 대한 연구)

  • Jeong, Seok Il;Lee, Seung Oh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.239-246
    • /
    • 2017
  • There are various transversal structures (small dams or drop structures) in median and small streams in Korea. Most of them are concrete structures and it is so hard to exclude low-level water. Unless drainage valves and/or gates would not be installed near bottom of bed, sediment from upstream should be deposited and also contaminants attached to the sediments would devastatingly threaten the water quality and ecosystem. One of countermeasures for such problem is the bypass pipe installed underneath the transversal structure. However, there is still issued whether it would be workable if the gravels and/or stones would roll into and be not excluded. Therefore, in this study, the conditions to exclude the rip stone which enter into the bypass pipe was reviewed. Based on sediment transport phenomenon, the behavior of stones was investigated with the concepts from the critical shear stress of sediment and d'Alembert principle. As final results, the basis condition (${\tau}_c{^*}$) was derived using the Lagrangian description since the stones are in the moving state, not in the stationary state. From hydraulic experiments the relative velocity could be obtained. In order to minimize the scale effect, the extra wide channel of 5.0 m wide and 1.0 m high was constructed and the experimental stones were fully spherical ones. Experimental results showed that the ratio of flow velocity to spherical particle velocity was measured between 0.5 and 0.7, and this result was substituted into the suggested equation to identify the critical condition wether the stones were excluded. Regimes about the exclusion of stone in bypass pipe were divided into three types according to particle Reynolds number ($Re_p$) and dimensionless critical shear force (${\tau}_c{^*}$) - exclusion section, probabilistic exclusion section, no exclusion section. Results from this study would be useful and essential information for bypass pipe design in transveral structures.