• Title/Summary/Keyword: microclimate environments

Search Result 28, Processing Time 0.024 seconds

Subjective Wearing Sensation of Sleepwear and Comfort Properties of the Fabrics in Winter (겨울철 잠옷의 주관적 착용감과 잠옷 소재의 쾌적성능)

  • 권수애;최종명
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.3
    • /
    • pp.11-20
    • /
    • 2002
  • The purposes of this study were to investigate the subjective wearing sensation of sleepwear, and to evaluate the comfort properties of fabrics used in the sleepwear. Design of experimental clothing was pajamas made with four types of woven fabrics: plain weave and satin weave made by cotton and polyester. The comfort properties were evaluated with respect to thermal retention, Qmax, moisture regain, water vapor transmission, and air permeability. The wear trials of experimental clothing were performed in two different environments, single-detached unit($23{\pm}1^{\circ}C$, $45%{\pm}3%$ R.H.) and apartment($27{\pm}1^{\circ}C$, $40{\pm}3%$ R.H), to evaluate microclimate temperature and humidity, and subjective wearing sensation. The results obtained from this study were as follows: 1. There were significant differences between the two environments on the clothing microclimate. 2. In the single detached unit environment, the microclimate temperature who wore cotton sleepwear was significantly higher than that of subjects wore the polyester sleepwear, whereas the microclimate humidity who wore polyester sleepwear was higher than that of subjects wore the polyester sleepwear. 3. In the apartment environment, the microclimate temperature who wore the polyester sleepwear showed higher than that of cotton sleepwear, whereas there was no significant difference between the cotton and polyester sleepwear on the microclimate humidity. 4 There were partially significant differences in subjective wearing sensation according to the fiber md weaving type of sleepwear regardless environment. 5. There were also partially significant correlations among the heat/moisture transmission properties of fabrics, the clothing microclimate and the subjective wearing sensation of sleepwear.

A Study on the microclimate Improvement of an apartment complex using the Envi-Met model (Envi-Met 모델을 이용한 공동주택단지의 미기후 환경 개선방향에 관한 연구)

  • Kim, Jung-Kwon;Jung, Eung-Ho;Kim, Dae-Wuk;Ryu, Ji-Won;Cha, Jae-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.297-302
    • /
    • 2008
  • Urbanization has caused population influx into cities, creating housing problems, and housing developmental plans have often resulted in high-rise and high-density housing complexes. Such development have seldom incorporated the environmental factors associated with the complexes and the surroundings, just being busy in increasing the volume of the housing supplies, and as a result, various environmental problems, such as disruption of the air flow, reduction of sunlight exposure amount, and temperature rise, have occurred, deteriorating the living environments. Accordingly, the objectives of this paper are to find out the causes of the problems in the contemporary complex development plans from the urban environmental viewpoint through the investigative analysis of microclimate environment in those complexes, and, further, to present a residential complex planning technique and developmental direction so as to remedy the problems described above. Then a 3-D microclimate model 'Envi-Met' was employed to analyze and predict on the related issues, per the selected planning factors.

  • PDF

Clothing Temperature Changes of Phase Change Material-Treated Warm-up in Cold and Warm Environments

  • Choi Kyeyoun;Chung Hyejin;Lee Boram;Chung Kyunghee;Cho Gilsoo;Park Mikyung;Kim Yonkyu;Watanuki Shigeki
    • Fibers and Polymers
    • /
    • v.6 no.4
    • /
    • pp.343-347
    • /
    • 2005
  • The purpose of this study was to investigate the appropriate amounts of phase change materials to give objective and subjective wear sensations. Vapor-permeable water-repellent fabrics with (WR-PCM) and without (WR) octadecane containing microcapsules were obtained by wet-porous coating process. Then, calculating the area of the WR-PCM treated clothes, we estimated the total calories of the clothing by multiplying the heat of fusion and heat of crystallization of PCM to the calculated area. Wear tests were conducted in both warm environment $(30^{\circ}C,\;65\%\;RH)$ and cold environment $(5^{\circ}C,\;65\%\;RH)$ with sports warm up style experimental garments made with WR and WR-PCM fabrics. Rectal, skin, and clothing microclimate temperatures, saliva and subjective evaluation measurements were done during the wear test. There was no difference of rectal and mean skin temperatures between WR and WR-PCM, but the clothing microclimate temperature of WR-PCM under warm environment was slightly lower than that of WR. In cold environment, WR-PCM showed much higher temperature than in WR. Saliva change did not appear between clothes, but did between two environments. Although subjective sensation between WR and WR-PCM was not significantly different, WR-PCM was rated as cooler than WR in warm environment and as warmer than WR in cold environment. The results of this study indicated that octadecane containing microcapsules in water-repellent fabric provide cooling effect.

The use and potential applications of point clouds in simulation of solar radiation for solar access in urban contexts

  • Alkadri, Miktha F.;Turrin, Michela;Sariyildiz, Sevil
    • Advances in Computational Design
    • /
    • v.3 no.4
    • /
    • pp.319-338
    • /
    • 2018
  • High-performing architecture should be designed by taking into account the mutual dependency between the new building and the local context. The performative architecture plays an important role to avert any unforeseen failures after the building has been built; particularly ones related to the microclimate impacts that affect the human comfort. The use of the concept of solar envelopes helps designers to construct the developable mass of the building design considering the solar access and the site obstruction. However, the current analysis method using solar envelopes lack in terms of integrating the detailed information of the existing context during the simulation process. In architectural design, often the current site modelling not only absent in preserving the complex geometry but also information on the surface characteristics. Currently, the emerging applications of point clouds offer a great possibility to overcome these limitations, since they include the attribute information such as XYZ as the position information and RGB as the color information. This study particularly presents a comparative analysis between the manually built 3D models and the models generated from the point cloud data. The modelling comparisons focus on the relevant factors of solar radiation and a set of simulation to calculate the performance indicators regarding selected portions of the models. The experimental results emphasize an introduction of the design approach and the dataset visibility of the 3D existing environments. This paper ultimately aims at improving the current architectural decision of support environment means, by increasing the correspondence between the digital models for performance analysis and the real environments (context of design) during the conceptual design phase.

Effect of Ondol on Physiological Responses during Sleeping (IV) (온돌환경이 수면시의 생리반응에 미치는 영향 (제4보))

  • Lee, Soon-Won;Kweon, Soo-Ae
    • Korean Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.183-195
    • /
    • 1998
  • The purpose of this study is to investigate the effect of Ondol on the bedclimate, microclimate and physiological responses of occupants. Four healthy female subjects slept for seven hours in thermal environment of detached house and apartment respectively. Their bedclimate, microclimate, skin temperature, weight loss of body, weight of bedcloth and sleepwear, body movement and subjective sensation were measureed for this study. The results were as follows; The differences of bedclimate, microclimate, skin temperature were significant according to season and residence styles. The occupants of the detached house showed higher temperature and humidity inside quilt and clothes than those of the apartment did on apartment environment. The occupants of the detached house showed higher weight losses of body, heavier weights of quilt than those of the apartment did on apartment environment in the spring, autumn and winter, lower weight losses of mattress in the autumn and winter. The occupants of the detached house moved more than those of the apartment on apartment environment when sleeping. The occupants of the detached house felt higher thermal sensation and lower humidity sensation than those of the apartment did. The occupants of the detached house felt more comfortable than those of the apartment on detached house environment, while the occupants of the apartment felt more comfortable than those of the detached house on apartment environment. The thermal environments of the apartment and the detached house had an effect on the bedclimates, microclimates of occupants and therefore the physiological responses such as skin temperature, rectal temperature, weight loss of body, perspiration and subjective sensation are different during sleeping according to their residential styles on the same environment.

  • PDF

Research trends on prevention of heat stroke using clothing: Focusing on practical research in Japan (의복을 활용한 열중증 예방 대책에 관한 연구 동향 조사: 일본의 실용 지향적 연구를 중심으로)

  • Son, Su-Young
    • Human Ecology Research
    • /
    • v.56 no.5
    • /
    • pp.473-491
    • /
    • 2018
  • This study identifies Japanese study content on heat stroke prevention measures using clothes, provides basic data for quantitative wearing assessment studies, presents a developmental direction for those, and helps invigorate further research. Studies were collected concerning clothing-based heat stroke measures in order to analyze the following factors: current status of heat stroke by industry and working environment, heat stroke and body cooling method, clothing microclimate and air circulation in a hot environment, hot environments and wearable sensors, and heat stress reduction and skin exposure. The current WBGT standard does not consider the diversity of wearing clothes according to the working environment. Therefore, it is preferable to add a correction value in consideration of design, materials, and ventilation to prevent heat strokes. For the heat stroke and body cooling method, wearing water-perfused clothing is effective to reduce heat stress and maintain exercise ability. Changing the material and design of clothing or wearing air-conditioned clothing can improve ventilation and the clothing microclimate. However, further evaluation is needed on the effectiveness of air-conditioned clothing as a heat stroke prevention product. The measurement method using a wearable sensor can provide real-time data on the body response due to working in a hot environment. Therefore, it is an effective alarm for heat stroke. Skin exposure area and heat dissipation efficiency should be considered to prevent heat stroke. Reducing the covering area by exposing the head, neck, and limbs, and wearing breathable material can prevent heat stroke from increased body temperature.

Physiological Effects of Different Underwear Materials Thermoregulatory Response during Exercise with Sweating at Cold Environments (한랭환경하에서 운동발한시 인체의 체온조절반응에 대한 내의소재의 생리학적 의의)

  • Kwon, Oh-Kyung;Kim, Tae-Kyu;Son, Du-Hun;Park, Sung-Han
    • Fashion & Textile Research Journal
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1999
  • This study conducted 4 different kinds of underwear materials, which were A (Cotton 100%), B (Wool 100%), C (Cotton/Wool, 50/50%) and D (Acrylic/Cotton, 50/50%) and were done in a climate chamber under cold ambient $10{\pm}1^{\circ}C$, $40{\pm}5%RH$ by 6 male subjects who were in good health. Physiological parameters such as rectal and local skin temperature(forehead, forearm, hand, trunk, thigh, leg, foot, back and chest), heart rate, body weight loss, clothing microclimate, blood lactic acid concentration, and wearing sensation were measured. Started with a 15-min rest period, 15-min of exercise 1 (the condition of 4.5 mile/hr walking speed equivalent to with 8.5 Kcal energy consumption on the treadmill) period, 15-min rest period, exercise 2 (after 3minutes warming-up at 3.0. 3.7, 4.5. 5.2. 6.0, 6.7 mile/hr) until exhaustion period, and final 15-min of recovery period were performed. The results were as follows: The lowest mean skin temperature was acrylic/cotton in order of wool > cotton/wool > cotton > acrylic/cotton (F=13. 79. p<0.00l). Most of all skin temperature by parts of body had turned out in sequence of temperature wool > cotton/wool > acrylic/cotton > cotton. Fore arm part showed highest temperature about $32.43^{\circ}C$ on wool and had a tendency approximately $1.8^{\circ}C$ higher than cotton which had the lowest temperature, and had the biggest difference among garments in terms of skin temperature. The back temperature within clothing showed about $2^{\circ}C$ higher than the chest temperature within clothing. but the back humidity within clothing showed about 4~12% higher than the chest humidity within clothing. Body weight loss by each garment was this sequence; cotton > acrylic/cotton > wool > cotton/wool.

  • PDF

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments(2) - Comparison in Terms of Thermophysiological Properties Between New Cooling Vest and Standard Cooling Vest - (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest연구(2) - 개발제품의 온열생리학적특성 -)

  • Kwon, Oh-Kyung;Kim, Tae-Kyo;Kim, Jin-A
    • Fashion & Textile Research Journal
    • /
    • v.2 no.4
    • /
    • pp.346-352
    • /
    • 2000
  • The purposes of this study are finding out thermophysiological properties throughout wearing experiment with standard cooling vest as well as providing data in order to design and apply more comfortable cooling vest. To do this study, we produced cooling vest newly. 1. Rectal temperature was ascended approximately from $37.2^{\circ}C$ to $38.05^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from $32.8{\sim}36.5^{\circ}C$, it was descended $1.0{\sim}1.1^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower $0.5^{\circ}C$. 2. While wearing developed cooling vest, it was found that they had lower tendency than standard cooling vest. Specifically in case of temperature within clothing (chest) $0.2{\sim}2.0^{\circ}C$ in case of humidity within clothing 2~8%RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. 3. In subjective sensation, standard cooling vest made negative response during experiment period from participants, but new cooling vest was nearing to comfortable area. It was con finned from above conclusions that wearing developed product is more effective in terms of comfort and reduction of heat stress in situation of working in hot environment.

  • PDF

Wearing Effects of Winter Gloves in Cold Environment on Physiological Responses and Subjective Perception in Elderly Females (추운 환경에서 보온용 장갑 착용이 고령 여성의 인체 생리 반응 및 주관적 감각에 미치는 효과)

  • Park, Joonhee;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.6
    • /
    • pp.866-876
    • /
    • 2019
  • This study examined the physiological and psychological effects of wearing gloves at rest in a cold environment. Seven elderly females participated in two separate trials: wearing gloves (WG) and bare hands (BH). The experiment was conducted for 60 min in a climatic chamber (air temperature 7.8±0.3℃ with 44±2%RH) with a sedentary posture. Microclimate temperature on the left palm was 4.16℃ higher in WG compared to that in BH (p<.1). Microclimate temperature on the chest during the last 5 min increased compared to the initial 5 min only in WG (p<.05). During the last 5 min, skin temperatures at the arm and hand in WG were higher than those in BH (p<.05). There was no statistical difference in the change of rectal temperature between WG and BH. Heart rate in BH was significantly higher compared to the WG (p<.05). Subjects also felt less cold on the whole body and hand in WG than those in BH (p<.05). The findings indicate that wearing gloves for elderly females affected the distribution of skin temperature and cardiovascular response in cold environments. Elderly females should be informed about the importance of wearing gloves through the clothing guideline in winter.

Efficacy of Cooling Vest for Auxiliary Body Cooling in Hot Environments (1) -Thermophysiological Response of Human Body in Local Cooling- (고온환경 하에서 착용하는 인체냉각 보조도구로서의 Cooling Vest 연구(1) -Local Cooling에 따른 인체의 온열생리학적 특성-)

  • Kwon, Oh Kyung;Kim, Jin-A;Kim, Tae Kyu
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.265-271
    • /
    • 2000
  • Heat stress results in fatigue, a decline in strength, alertness., and mental capacity. The problem is compounded when high humidity exists. To help relieve worker heat stress, many types of cooling units are marketed. While workers may experience some cooling, critical body core temperatures often continue to elevate. This study was designed to find the effects of three kinds of cooling vest with portable frozen gel strips on thermophysiological parameters and on temperature and humidity within clothing. The heart rate, rectal, and skin temperature as well as sweat rate and clothing microclimate were measured during 80 min in 5 healthy males. Inquiries were also made into the subjective rating thermal, humidity comfort, and fatigue sensations. The main findings in our experiments are as follows: (a) Physiological parameters such as rectal temperature was the lowest in garb A1, intermediate in garb A, and the highest in garb A2 throughout the experiment. And mean skin temperature was the lowest in garb A, intermediate in garb A1, and the highest in garb A2; (b) Temperature and humidity within clothing (back) were garb in Al, intermediate in garb A, and the highest in garb A2. But the temperature and humidity within clothing (chest) were garb in A, intermediate in garb A1, and the highest in garb A2; (c) Most participants (4 out of 5 persons) answered that they felt more comfortable and fatigueless in garb A1 than in garb A and A2. It is concluded that local cooling in garb A1 of the upper torso could physiological reduce the thermal strain in participants wearing cooling vest.

  • PDF