• Title/Summary/Keyword: microwave method

Search Result 1,183, Processing Time 0.032 seconds

Abrasion of PET Fabrics by Using Microwave Energy (Microwave Energy를 이용한 PET 직물의 Abrasion)

  • Cho, In-Sul;Lee, Eun-Woo;Cho, Kyu-Min;Chang, Du-Sang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.69-72
    • /
    • 1999
  • The aim of this study is to enhance the abrasion of the hydrolyzed polyethylene terephthalate(PET) fabrics by using microwave energy. In other to achieve the aforementioned objectives, PET fabrics were hydrolyzed in NaOH solution by using abrasion method such as dipping, microwave-dipping, pad steam-dry, and pad microwave-dry, and then abrasion of the hydrolyzed PET fabrics was calculated and investigated. As a result obtained form this study, the abrasion of the hydrolyzed PET fabrics is directly proportional to hydrolyzed time and NaOH concentration. And also, microwave-dipping method and pad microwave-dry method showed remarkable abrasion effect than the others.

  • PDF

Development of Microwave Extraction Method for the Active Ingredients and Functional Constituents of Paeonia Root (마이크로웨이브 추출방법을 이용한 작약의 유효성분 추출 및 생리활성 측정)

  • Lee, Hyojin;Jang, Kyoung won
    • Korean Journal of Pharmacognosy
    • /
    • v.52 no.3
    • /
    • pp.157-162
    • /
    • 2021
  • The heat-mediated reflux apparatus extraction of Paeonia lactiflora Pall. has been widely used as a traditional extraction method. In this paper, the microwave apparatus extraction method of Paeonia Radix was performed and the active ingredients and functional constituents were compared with the reference extraction method. The most effective extraction condition of albiflorin using the microwave was 120℃ in 50% methanol, and paeoniflorin was maximally extracted at 60℃. The reduced level of paeoniflorin molecule at high-pressure and high-temperature extraction condition was caused by the molecular instability. Additionally, the microwave extraction of 50% methanol extracts at 150℃ showed the highest functional constituents determined by in vitro DPPH radical scavenging activity, polyphenol concentration, and tyrosinase inhibition assay. The microwave apparatus was adapted as a rapid, low-cost, and environmentally friendly method to extract active ingredients and the practical extraction conditions of Paeonia Radix can be used in industrial applications.

Comparison of Microwave with Conventional Wet-Digestion Methods for the Element Analysis of Plant and Compost (식물체 및 퇴비 성분 분석을 위한 마이크로웨이브 분해법과 기존 습식 분해법의 비교)

  • Nam, Jae-Jak;Cho, Nam-Jun;Jeong, Yee-Guen;Lee, Sang-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.3
    • /
    • pp.253-258
    • /
    • 1998
  • To verify the suitability of microwave digestion method for analyzing macro nutrients and metals. K, Ca, Mg, Cu, Zn, and Mn contents in plant and composts were investigated comparing with conventional wet digestion method. Because it takes short time to digest metal samples by using microwave method compared with conventional wet digestion method. Digestion time for metal samples was four to six hours long for wet digestion, while one hour long for microwave digestion. Determinant coefficients of Cu, Mn, Zn, Ca, K, and Mg contents between two analyzing methods were 0.99, 0.99, 0.94. 0.97, 0.98, and 0.91, respectively. In the case of Ca and K, microwave digestion method analyzed their contents relatively low compared with wet digestion method. Meanwhile, microwave digestion method analyzed the contents for Cu, Ma, and Zn relatively high compared with wet digestion method. This study results in that microwave digestion method could be an alternative to replacing conventional wet digestion method.

  • PDF

A Study on Measuring Technique of Electromagnetic Wave Absorbing Characteristics of Microwave Absorbers (전파흡수체의 전파흡수특성측정기법에 관한 연구)

  • 김동일;안영섭;정세모
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1992.10a
    • /
    • pp.2-29
    • /
    • 1992
  • According to the increase of occupation density of microwave frequency band on use microwave environments have been congested extensively. For shielding unnecessary electromagnetic wave of preventing the electromagnetic wave reflection a good conductor a low resistive material or a lossy material is mainly used. As a method to measure the absorbing characteristics of microwave absorber the fundamental microwave measuring method can be used. There is however a big problem in measuring errors since the wavelength of microwave is very short especially as in the case as microwave absorber for RADAR. Therefore this research aimed to a converting adaptor of 20mm${\Phi}$ coaxial tube from a Type-N connector to 20mm${\Phi}$ coaxial tube and to use it for designing microwave absorber and evaluating absorbing characteristics. Furthermore the measurements of absorbing characteristics and material constants have performed and reviewed which were carried out by using the coaxial tube in the short type and by using rectangular waveguide respectively As a result the validity of the measured values have been confirmed.

  • PDF

Accuracy and Precision of Microwave Oven Digestion/Atomic Absorption Spectrophotometry for Analyzing Airborne Chromium Collected on MCE Filter in Plating Operation (도금공정 크롬시료 분석을 위한 Microwave Oven Digestion/Atomic Absorption Spectrophotometry 방법의 정확도 및 정밀도 평가)

  • Lee, Byung-Kyu;Lee, Ji-Tae;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.48-55
    • /
    • 2001
  • The purpose of this study was to evaluate the analytical accuracy and precision of microwave oven digestion/atomi absorption spectrophotometry (AAS) for analyzing airborne chromium collected on mixed cellulose ester membrane (M filter from the work environment, and to compare the accuracy and the precision with those of the National Institute for Occupational Safety and Health (NIOSH) Method #7024 hot plate digestion/AAS method. For this study, field air sample pairs were collected from a electroplating process, and spiked samples in a laboratory were prepared and using these samples. Two digestion methods were comp; and evaluated in terms of recovery rate and bias as indices of accuracy and coefficient of variation as a index of precision. The results and conclusions are as follows. In spiked samples, the accuracies (% mean recoveries) of hot plate/AAS and microwave oven/AAS method were 97.19%, 97.1%, respectively, and the precisions (pooled respectively, and the precisions (pooled coefficient of variance, $CV_{pooled}$) 6.93% and 3.88%, respectively. The biases of hot plate ani microwave oven methods were 4.56 - 14.7% and 2.22 - 7.42% respectively. There was no statistically significant difference between hot plate and microwave oven methods recovery rates of spiked samples (p>0,05). Also, no statistically significant difference was shown among the concentrations of air samples determined by two method (p>0.05). In conclusion, microwave oven/AAS method h excellent accuracy and precision, and advantages such as time-saving and simple procedure in comparison with the classical NIOSH method. Therefore, this method can be use widely to analyze airborne chromium collected on MCE filter from the work environments.

  • PDF

Numerical Method for Computing the Resonant Frequencies and Q-factor in Microwave Dielectric Resonator

  • Kim, Nam-young;Yoo, Hojoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.245-248
    • /
    • 1997
  • The dielectric resonators(DRs) with dielectric properties are widely used in microwave integrated circuit(MICs) and monolithic microwave integrated circuits(MMICS). The variational method as numerical simulation scheme would be applied to calculate the resonant frequencies(fr) and Q-factors of microwave dielectric resonators. The dielectric resonator with a cylindrical “puck” structure of high dielectric material is modeled in this simulation. The parameters, such as the diameter, the height, and the dielectric constant of dielectric resonator, would determine the resonant frequency and the Q-factor. The relationship between these parameters would effect each other to evaluate the approximate resonant frequency. This simulation method by the variational formula is very effective to calculate fr, and Q-factor. in high frequency microwave dielectric resonator The error rate of the simulation results and the measured results would be considered to design the microwave dielectric resonators.

  • PDF

A Study on the Measurement of Water Content in Hydrogel Contact Lens by Gravimetric Method (중량측정법에 의한 하이드로젤 콘택트렌즈의 함수율 측정에 관한 연구)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.59-63
    • /
    • 2008
  • Purpose: The purpose of this study is to understand a relation of water content measurement with two different method, water removal method and dry method. Methods: 72 hydrogel contact lens containing various water content (ranged from 47% to 58%) were measured by the gravimetric method at 20$^{\circ}C$and 21% of the humidity. We weighed the dried test specimen at room temperature for 30 min after cooling. Results: In dry blotting method, the water content was measured to 47.43${\pm}$8.48%. The water contents was measured to 48.15${\pm}$8.36% with wet blotting condition. It was found that wet blotting method showed the higher water content of about 7% than dry blotting method. In water content with two dry methods, each of results was measured by 47.89${\pm}$8.06% and 49.56${\pm}$7.06%. In case of microwave method, the water content was measured significantly higher water content of about 1.67% than vacuum oven method. However, no statistical difference was found (p>0.05). Conclusions: In water removal method (Dry blotting method and Wet blotting method) to weigh hydrated test specimen, wet blotting method showed significantly higher water content than dry blotting method. Also in case of dry methods (vacuum oven and microwave) to weigh dry test specimen, water content of microwave method showed higher water content than vacuum oven method, but it should be noted that microwave oven method must be used carefully to measure accurateness on the specimen position and wave power.

  • PDF

Development of Modified Jeung-pyun Heated by Microwave Method (전자레인지를 이용한 개량 증편의 제조)

  • 김혁일
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.5
    • /
    • pp.878-885
    • /
    • 1997
  • Effect of various ingredients and cooling methods on the quality of modified Jeung-pyun(traditional Korean steamed rice cake) were studied. Three different kinds of wheat flours(strong, medium, and weak) were studied to evaluate the volume and firmness of Jeung-pyun. Weak flour showed the maximum volume and good sensory results. The optimum ratio of ingredients was flour : water ; sugar ; Tak-Ju=100 : 20 : 20 : 50 for steaned Jeung-pyun. When three different cooking methods were compared, the maximum volume showed from convection oven method, but the crust color of Jeung-pyun was like bread. Steaming method showed higher volume than that of product heated by microwave method. The optimum formula ratio for the microwave method was flour ; water ; sugar ; Tak-Ju = 100 : 30 : 20 : 50, which required 10% higher added water content than that of steaming. When wheat flour was used instead of rice flour, the addition of 5% normal corn starch increased volume of both steamed and microwave cooked products. In the case of added modified starches to Jeung-pyn, 5% $\alpha$-waxy corn starch showed the highest volume in steaming method. When rice flour was used, the addition of 5%$\alpha$-waxy corn starch also showed highest volume f both steamed and microwave cooked products. The firmness of steamed wheat flour Jeung-pyun, containing 5%$\alpha$-corn starch was higher firmness than that of control and other added samples. Microwave cooked products showed two or three times higher firmness of steaming products. The use of wrap(uni-wrap) and stabilizer(METHOCEL) decreased the firmness of microwave cooked wheat flour Jeung-pyun to 200~300g compared with that of untreated Jeung-pyun.

  • PDF

Microwave characteristics of traveling-wave modulator considering the microwave feedline (마이크로파 feedline을 고려한 진행파형 광변조기의 특성 분석)

  • 구민주;옥성해;윤영설;문연태;김도균;최영완
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.41-47
    • /
    • 2004
  • In this paper, we analyze the microwave characteristics of traveling-wave electro-absorption modulator (TW-EAM) considering the microwave feedline and the impedance mismatch. The TW-EAM is analyzed by using the equivalent circuit model. The capacitance and the inductance of the equivalent circuit are evaluated by using 3-dimensional finite difference time domain (FDTD) method, while the microwave feedline is analyzed by momentum method. In a viewpoint of microwave characteristics, we present the effect of the structure and the length of microwave feedline.

Microwave Absorbing Characteristic Improvement by Permittivity Control of Ferrite Composite Microwave Absorber (유전율제어에 의한 복합 Ferrite 전파흡수체의 성능향상)

  • 신재영;권형주;오재희
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.4
    • /
    • pp.415-419
    • /
    • 1994
  • The material constants(the complex permeability and permittivity) of ferrite composite determine its microwave absorbing characteristics. Therefore, in order to improve the microwave absorbing characteristics, it is necessary to control the material constants of the ferrite composite. In this study, the method of improving microwave absorbing characteristics by control of permittivity of ferrite composite which has not satisfying matching condition in C-X band (4 GHz~12.4 GHz) was investigated. It was possible to control the permittivity by adjusting graphite loading ratio in the ferrite composite microwave absorber. It was also concluded that the control of permittivity of ferrite composite is effective method to improve the microwave absorbing characteristics.

  • PDF